3D visualization and quantification of rat cortical bone porosity using a desktop micro-CT system: a case study in the tibia
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Summary: Although micro‐computed tomography (micro‐CT) has become the gold standard for assessing the 3D structure of trabecular bone, its extension to cortical bone microstructure has been relatively limited. Desktop micro‐CT has been employed to assess cortical bone porosity of humans, whereas that of smaller animals, such as mice and rats, has thus far only been imaged using synchrotron‐based micro‐CT. The goal of this study was to determine if it is possible to visualize and quantify rat cortical porosity using desktop micro‐CT. Tibiae (n = 10) from 30‐week‐old female Sprague‐Dawley rats were imaged with micro‐CT (3 μm nominal resolution) and sequential ground sections were then prepared. Bland–Altman plots were constructed to compare per cent porosity and mean canal diameter from micro‐CT (3D) versus histology (2D). The mean difference or bias (histology – micro‐CT; ±95% confidence interval) for per cent porosity was found to be −0.15% (±2.57%), which was not significantly different from zero (P= 0.720). Canal diameter had a bias (±95% confidence interval) of −5.73 μm (±4.02 μm) which was found to be significantly different from zero (P < 0.001). The results indicated that cortical porosity in rat bone can indeed be visualized by desktop micro‐CT. Quantitative assessment of per cent porosity provided unbiased results, whereas direct analysis of mean canal diameter was overestimated by micro‐CT. Thus, although higher resolution, such as that available from synchrotron micro‐CT, may ultimately be required for precise geometric measurements, desktop micro‐CT – which is far more accessible – is capable of yielding comparable measures of porosity and holds great promise for assessment of the 3D arrangement of cortical porosity in the rat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, at the 3 µm isotropic voxel resolution achieved here, the bias of Ct.Po is reduced to only 0.15%, whereas Ca.Dm is afflicted with a relatively large bias of -5.73 ± 4.02 µm (Britz et al., 2010).”
From Experimental Aqueous Alteration of Cortical Bone Microarchitecture Analyzed by Quantitative Micro-Computed Tomography (2021) · cites this paper as Britz et al., 2010
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Research works printed but not linked: 35
- 10.1007/s00776-006-1104-z · DOI · Paper page
- 10.1097/00005768-200212000-00015 · DOI
- 10.22203/eCM.v007a05 · DOI
- 10.1359/jbmr.090711 · DOI
- 10.1359/jbmr.040124 · DOI · Paper page
- 10.1016/0021-9290(76)90006-3 · DOI · Paper page
- 10.1007/s00198-009-0993-z · DOI
- 10.2106/00004623-195840020-00015 · DOI · Paper page
- 10.1002/ar.b.10024 · DOI · Paper page
- 10.1007/s00223-003-0071-z · DOI · Paper page
- 10.1007/s00223-005-0274-6 · DOI · Paper page
- 10.1016/j.bone.2006.11.011 · DOI · Paper page
- Dilmanian F.A., 1992, Computed tomography with monochromatic x rays, Am. J. Physiol. Imaging, 7, 175
- 10.1002/jbmr.5650040103 · DOI · Paper page
- 10.3109/10520295809111862 · DOI
- 10.1046/j.1365-2818.1997.1340694.x · DOI · Paper page
- 10.1359/jbmr.1999.14.7.1167 · DOI · Paper page
- 10.1016/j.biomaterials.2004.01.047 · doi:10.1016/j.biomaterials.2004.01.047
- 10.1016/j.biomaterials.2008.10.056 · DOI · Paper page
- 10.1002/jor.1100080608 · DOI · Paper page
- 10.1152/japplphysiol.00495.2005 · DOI
- 10.1016/j.bone.2007.04.192 · DOI
- 10.1529/biophysj.108.135939 · DOI
- Mohsin S., 2002, Three‐dimensional reconstruction of Haversian systems in ovine compact bone, Eur. J. Morphol., 40, 309, 10.1076/ejom.40.5.309.28901 · doi:10.1076/ejom.40.5.309.28901
- 10.3233/THC-1996-4112 · doi:10.3233/thc-1996-4112
- 10.1016/S8756-3282(98)00068-4 · DOI · Paper page
- 10.1172/JCI111096 · DOI · Paper page
- Peyrin F., 2000, Perspectives in three‐dimensional analysis of bone samples using synchrotron radiation microtomography, Cell. Mol. Biol. (Noisy-le-grand), 46, 1089
- 10.1111/j.1469-7580.2007.00693.x · DOI · Paper page
- 10.1359/jbmr.070703 · DOI · Paper page
- 10.1002/jemt.20720 · DOI
- 10.1007/s002239900699 · doi:10.1007/s002239900699
- 10.1016/j.jhevol.2007.09.018 · DOI
- 10.1002/aja.1001490302 · doi:10.1002/aja.1001490302
- 10.1007/BF02685001 · DOI
Cited by
PAUWELS, E., VAN LOO, D., CORNILLIE, P., BRABANT, L., & VAN HOOREBEKE, L. (2013) · Journal of Microscopy · doi:10.1111/jmi.12013 · Cited by 212
“…has proven to be a valuable technique for the imaging of bone structures and other mineralized tissues (Thomsen et al., 2005; Neues & Epple, 2008; Britz et al., 2010; Particelli et al., 2012), but a major drawback is that the sufficiently detailed visualization of soft tissues is more difficult.”
BackgroundSharma (2018) · doi:10.1016/j.bone.2018.01.019 · Cited by 70
“0 μm, posterior region) is also similar to the values of canal diameter reported for the tibia and femur of untreated mice and rats (10-18 μm) [3, 4, 32, 33].”
MethodResultKral, A. G., Ziegler, A., Tütken, T., & Geisler, T. (2021) · Frontiers in Earth Science · doi:10.3389/feart.2021.609496 · Cited by 10
Metadata
- Authors
- BRITZ, H. M., JOKIHAARA, J., LEPPÄNEN, O. V., JÄRVINEN, T., & COOPER, D. M. L.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2010-09-15
- Volume
- 240
- Issue
- 1
- Pages
- 32-37
- ISSN
- 0022-2720
- 1365-2818
- Cited by
- 46
- References
- 1
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D visualization and quantification of rat cortical bone porosity using a desktop micro-CT system: a case study in the tibia. https://app.cochat.ai/papers/10.1111/j.1365-2818.2010.03381.x
- The paper
- BRITZ, H. M., JOKIHAARA, J., LEPPÄNEN, O. V., JÄRVINEN, T., & COOPER, D. M. L. (2010). 3D visualization and quantification of rat cortical bone porosity using a desktop micro-CT system: a case study in the tibia. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.2010.03381.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.