The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Ultrastructural Properties in Cortical Bone Vary Greatly in Two Inbred Strains of Mice as Assessed by Synchrotron Light Based Micro- and Nano-CT
Open accessAbstract
Nondestructive SR-based μCT and nano-CT methods have been designed for 3D quantification and morphometric analysis of ultrastructural phenotypes within murine cortical bone, namely the canal network and the osteocyte lacunar system. Results in two different mouse strains, C57BL/6J-Ghrhrlit/J and C3.B6-Ghrhrlit/J, showed that the cannular and lacunar morphometry and their bone mechanics were fundamentally different. Introduction: To describe the different aspects of bone quality, we followed a hierarchical approach and assessed bone tissue properties in different regimens of spatial resolution, beginning at the organ level and going down to cellular dimensions. For these purposes, we developed different synchrotron radiation (SR)-based CT methods to assess ultrastructural phenotypes of murine bone. Materials and Methods: The femoral mid-diaphyses of 12 C57BL/6J-Ghrhrlit/J (B6-lit/lit) and 12 homozygous mutants C3.B6-Ghrhrlit/J (C3.B6-lit/lit) were measured with global SR μCT and local SR nano-CT (nCT) at nominal resolutions ranging from 3.5 μm to 700 nm, respectively. For volumetric quantification, morphometric indices were determined for the cortical bone, the canal network, and the osteocyte lacunar system using negative imaging. Moreover, the biomechanics of B6-lit/lit and C3.B6-lit/lit mice was determined by three-point bending. Results: The femoral mid-diaphysis of C3.B6-lit/lit was larger compared with B6-lit/lit mice. On an ultrastructural level, the cannular indices for C3.B6-lit/lit were generally bigger in comparison with B6-lit/lit mice. Accordingly, we derived and showed a scaling rule, saying that overall cannular indices scaled with bone size, whereas indices describing basic elements of cannular and lacunar morphometry did not. Although in C3.B6-lit/lit, the mean canal volume was larger than in B6-lit/lit, canal number density was proportionally smaller in C3.B6-lit/lit, so that lacuna volume density was found to be constant and therefore independent of mouse strain and sex. The mechanical properties in C3.B6-lit/lit were generally improved compared with B6-lit/lit specimens. For C3.B6-lit/lit, we observed a sex specificity of the mechanical parameters, which could not be explained by bone morphometry on an organ level. However, there is evidence that for C3.B6-lit/lit, the larger cortical bone mass is counterbalanced or even outweighed by the larger canal network in the female mice. Conclusions: We established a strategy to subdivide murine intracortical porosity into ultrastructural phenotypes, namely the canal network and the osteocyte lacunar system. Nondestructive global and local SR-based CT methods have been designed for 3D quantification and subsequent morphometric analysis of these phenotypes. Results in the two different mouse strains C57BL/6J-Ghrhrlit/J and C3.B6-Ghrhrlit/J showed that the cannular and lacunar morphometry and the biomechanical properties were fundamentally different.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Osteoporosis Prevention, Diagnosis, and Therapy
NIH Consensus Development Panel on Osteoporosis Prevention, D. (2001) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.285.6.785 · Cited by 5,529
Basic biomechanical measurements of bone: A tutorial
Turner, C. H., & Burr, D. B. (1993) · Bone · doi:10.1016/8756-3282(93)90081-k · Cited by 1,666 · cited 1×
“Ultimate force (Fu), work to failure (U), and stiffness (S) were calculated from the load-displacement curve as described elsewhere.((46)) Fu indicates the strength of the bone, whereas S reflects resistance to elastic deformation, and U is the required energy to initiate a fracture.”
MethodMcCalden, R. W., McGeough, J. A., Barker, M. B., & Court-Brown, C. M. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199308000-00009 · Cited by 709
Stiffness of compact bone: Effects of porosity and density
Schaffler, M. B., & Burr, D. B. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90186-8 · Cited by 652 · cited 1×
“Moreover, regarding the stiffness of cortical bone, the influence of small changes in the amount or density of bone tissue is even more pronounced than similar changes would exert in trabecular bone.((11)) Eventually, loss of cortical rather than loss of trabecular bone predominates in cases of proximal femur fracture…”
BackgroundAguirre, J. I., Plotkin, L. I., Stewart, S. A., Weinstein, R. S., Parfitt, A. M., Manolagas, S. C., & Bellido, T. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.060107 · Cited by 494
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401
Osteocyte density changes in aging and osteoporosis
Mullender, M. G., van der Meer, D. D., Huiskes, R., & Lips, P. (1996) · Bone · doi:10.1016/8756-3282(95)00444-0 · Cited by 265
Cited by
Guidelines for assessment of bone microstructure in rodents using micro–computed tomography
Bouxsein, M. L., Boyd, S. K., Christiansen, B. A., Guldberg, R. E., Jepsen, K. J., & Müller, R. (2010) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.141 · Cited by 4,433
Self-citationJepsen, K. J., Silva, M. J., Vashishth, D., Guo, X. E., & van der Meulen, M. C. (2015) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2539 · Cited by 333
A network of trans-cortical capillaries as mainstay for blood circulation in long bones
Grüneboom, A., Hawwari, I., Weidner, D., Culemann, S., Müller, S., Henneberg, S., Brenzel, A., Merz, S., Bornemann, L., Zec, K., et al. (2019) · Nature Metabolism · doi:10.1038/s42255-018-0016-5 · Cited by 307
High-resolution Computed Tomography for Clinical Imaging of Bone Microarchitecture
Burghardt, A. J., Link, T. M., & Majumdar, S. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1766-x · Cited by 296
Sharma (2018) · doi:10.1016/j.bone.2018.01.019 · Cited by 70
Metadata
- Authors
- Schneider, P., Stauber, M., Voide, R., Stampanoni, M., Donahue, L. R., & Müller, R.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-10-01
- Volume
- 22
- Issue
- 10
- Pages
- 1557-1570
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2076436405
- Cited by
- 187
- References
- 7
- FWCI
- 8.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrastructural Properties in Cortical Bone Vary Greatly in Two Inbred Strains of Mice as Assessed by Synchrotron Light Based Micro- and Nano-CT. https://app.cochat.ai/papers/10.1359/jbmr.070703
- The paper
- Schneider, P., Stauber, M., Voide, R., Stampanoni, M., Donahue, L. R., & Müller, R. (2007). Ultrastructural Properties in Cortical Bone Vary Greatly in Two Inbred Strains of Mice as Assessed by Synchrotron Light Based Micro- and Nano-CT. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.070703
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.