CoChat

Application of magnetic resonance imaging to measure fasting and postprandial volumes in humans

Open access
Fidler, J., Bharucha, A. E., Camilleri, M., Camp, J., Burton, D., Grimm, R., Riederer, S. J., Robb, R. A., Zinsmeister, A. R. · 2009 · Neurogastroenterology & Motility
Cited by 75

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Our aims were to measure the gastric volume response in excess of ingested meal volume (i.e. gastric accommodation), contribution of swallowed air to this excess, day‐to‐day variability of gastric volumes measured by MRI and their relationship to volumes measured by single‐photon‐emission computed tomography (SPECT). In 20 healthy volunteers, fasting and postprandial gastric volumes were measured after technetium 99m‐pertechnetate labeling of the gastric mucosa by SPECT and separately by MRI, using 3D gradient echo and 2D half‐Fourier acquisition single‐shot turbo spin echo (HASTE) sequences. Ten of these subjects had a second MRI exam to assess intra‐individual variation. Thereafter, another 10 subjects had two MRI studies during which they ingested the nutrient in 30 or 150 mL aliquots. During MRI, the postprandial gastric volume change exceeded the ingested meal volume by 106 ± 12 mL (Mean ± SEM). The HASTE and gradient echo sequences distinguished air from fluid under fasting and postprandial conditions respectively. This postprandial excess mainly comprised air (61 ± 5 mL), which was not significantly different when ingested as 30 or 150 mL aliquots. Fasting and postprandial gastric volumes measured by MRI were generally reproducible within subjects. During SPECT, postprandial volumes increased by 158 ± 18 mL; gastric volumes measured by SPECT were higher than MRI. MRI measures gastric volumes with acceptable performance characteristics; the postprandial excess primarily consists of air, which is not affected by the mode of ingestion. Gastric volumes are technique specific and differ between MRI and SPECT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2982.2008.01194.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 75

Metadata

Authors
Fidler, J., Bharucha, A. E., Camilleri, M., Camp, J., Burton, D., Grimm, R., Riederer, S. J., Robb, R. A., & Zinsmeister, A. R.
Venue
Neurogastroenterology & Motility
Publisher
Wiley
Published
2008-12-30
Volume
21
Issue
1
Pages
42-51
ISSN
  • 1350-1925 (ISSN-L)
  • 1365-2982
OpenAlex
W2025154933
Cited by
75
References
2
FWCI
5.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Application of magnetic resonance imaging to measure fasting and postprandial volumes in humans. https://app.cochat.ai/papers/10.1111/j.1365-2982.2008.01194.x
The paper
Fidler, J., Bharucha, A. E., Camilleri, M., Camp, J., Burton, D., Grimm, R., Riederer, S. J., Robb, R. A., & Zinsmeister, A. R. (2009). Application of magnetic resonance imaging to measure fasting and postprandial volumes in humans. Neurogastroenterology & Motility. https://doi.org/10.1111/j.1365-2982.2008.01194.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.