Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 209

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Wireless pH‐motility capsule for colonic transit: prospective comparison with radiopaque markers in chronic constipation

Open access
Camilleri, M., Thorne, N. K., Ringel, Y., Hasler, W. L., Kuo, B., Esfandyari, T., Gupta, A., Scott, S. M., Mccallum, R. W., Parkman, H. P., Soffer, E., Wilding, G. E., Semler, J. R., Rao, S. S.c. · 2010 · Neurogastroenterology & Motility

Abstract

Background Colon transit (CT) measurements are used in the management of significant constipation. The radiopaque marker (ROM) method provides limited information. Methods We proposed to validate wireless motility capsule (WMC), that measures pH, pressure and temperature, to ROM measurement of CT in patients with symptomatic constipation evaluated at multiple centers. Of 208 patients recruited, 158 eligible patients underwent simultaneous measurement of colonic transit time (CTT) using ROM (Metcalf method, cut off for delay >67 h), and WMC (cutoff for delay >59 h). The study was designed to demonstrate substantial equivalence, defined as diagnostic agreement >65% for patients who had normal or delayed ROM transit. Key Results Fifty‐nine of 157 patients had delayed ROM CT. Transit results by the two methods differed: ROM median 55.0 h [IQR 31.0–85.0] and WMC (43.5 h [21.7–70.3],P < 0.001. The positive percent agreement between WMC and ROM for delayed transit was ∼80%; positive agreement in 47 by WMC/59 by ROM or 0.796 (95% CI = 0.67–0.98); agreement vs null hypothesis (65%)P = 0.01. The negative percent agreement (normal transit) was ∼91%: 89 by WMC/98 by ROM or 0.908 (95% CI = 0.83–0.96); agreement vs null hypothesis (65%),P = 0.00001. Overall device agreement was 87%. There were significant correlations (P < 0.001) between ROM and WMC transit (CTT [r = 0.707] and between ROM and combined small and large bowel transit [r = 0.704]). There were no significant adverse events. Conclusions & Inferences The 87% overall agreement (positive and negative) validates WMC relative to ROM in differentiating slow vs normal CT in a multicenter clinical study of constipation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2982.2010.01517.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 209

Metadata

Authors
Camilleri, M., Thorne, N. K., Ringel, Y., Hasler, W. L., Kuo, B., Esfandyari, T., Gupta, A., Scott, S. M., Mccallum, R. W., Parkman, H. P., Soffer, E., Wilding, G. E., Semler, J. R., & Rao, S. S. C.
Venue
Neurogastroenterology & Motility
Publisher
Wiley
Published
2010-07-07
Volume
22
Issue
8
Pages
874
ISSN
  • 1350-1925 (ISSN-L)
  • 1365-2982
OpenAlex
W2104056805
Cited by
209
References
3
FWCI
14.46
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wireless pH‐motility capsule for colonic transit: prospective comparison with radiopaque markers in chronic constipation. https://app.cochat.ai/papers/10.1111/j.1365-2982.2010.01517.x
The paper
Camilleri, M., Thorne, N. K., Ringel, Y., Hasler, W. L., Kuo, B., Esfandyari, T., Gupta, A., Scott, S. M., Mccallum, R. W., Parkman, H. P., Soffer, E., Wilding, G. E., Semler, J. R., & Rao, S. S. C. (2010). Wireless pH‐motility capsule for colonic transit: prospective comparison with radiopaque markers in chronic constipation. Neurogastroenterology & Motility. https://doi.org/10.1111/j.1365-2982.2010.01517.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.