CoChat

Accuracy in assessment of colonic transit time with particles: how many markers should be used?

Abrahamsson, H., Antov, S. · 2010 · Neurogastroenterology & Motility
Cited by 29

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Colonic transit time (CTT) is often measured with particle methods in clinical practice, but few studies have evaluated the role of particle amounts for the results obtained. METHODS: Colonic transit time was studied in 28 subjects taking radiopaque particles for six consecutive days followed by an abdominal radiograph on day 7. Four distinguishable marker types were ingested simultaneously in an amount of 5, 10, 15, and 20 daily, respectively, and CTT calculated for each type as the number of retained markers divided by the daily intake. Reference values were based on 50 markers daily. KEY RESULTS: Accuracy measured as median deviation of CTT from reference was for 20 markers day(-1) 0.08 days, for 15 markers day(-1) 0.10 days, for 10 markers day(-1) 0.12 days, and for 5 markers day(-1) 0.20 days. The CTT values obtained with 5 markers day(-1) deviated significantly more from the reference value than CTT values obtained with 10 markers day(-1) (P < 0.05) and with 15 and 20 markers day(-1) (P < 0.01). Colonic transit times obtained with 20, 15, or 10 markers day(-1) did not differ significantly (P > 0.1). CONCLUSIONS & INFERENCES: Colonic transit time can be assessed with reasonable accuracy after repeated ingestion of particles. For clinical use, a daily amount of 10 or 12 markers is proposed for reporting CTT in days or hours, respectively. Doses below 10 daily yield a steeply increasing deviation from reference values.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2982.2010.01543.x

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 29

Metadata

Authors
Abrahamsson, H., & Antov, S.
Venue
Neurogastroenterology & Motility
Publisher
Wiley
Published
2010-06-24
Volume
22
Issue
11
Pages
1164-1169
ISSN
1350-1925 (ISSN-L)
OpenAlex
W1954425439
Cited by
29
References
6
FWCI
1.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy in assessment of colonic transit time with particles: how many markers should be used? https://app.cochat.ai/papers/10.1111/j.1365-2982.2010.01543.x
The paper
Abrahamsson, H., & Antov, S. (2010). Accuracy in assessment of colonic transit time with particles: how many markers should be used? Neurogastroenterology & Motility. https://doi.org/10.1111/j.1365-2982.2010.01543.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.