Effectiveness of sensor-augmented pump therapy in children and adolescents with type 1 diabetes in the STAR 3 study
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Maintenance of appropriate A1C values and minimization of hyperglycemic excursions are difficult for many pediatric patients with type 1 diabetes. Continuous glucose monitoring (CGM) sensor-augmented pump (SAP) therapy is an alternative to multiple daily injection (MDI) therapy in this population. RESEARCH DESIGN AND METHODS: Sensor-augmented pump therapy for A1C reduction (STAR 3) was a 1-yr trial that included 82 children (aged 7-12) and 74 adolescents (aged 13-18) with A1C values ranging from 7.4 to 9.5% who were randomized to either SAP or MDI therapy. Quarterly A1C values were obtained from all subjects. CGM studies were carried out at baseline, 6 months, and 12 months to quantify glycemic excursions [calculated as area under the glucose concentration-time curve (AUC)] and variability. In the SAP group, sensor compliance was recorded. RESULTS: Baseline A1C values were similar in subjects randomized to the SAP (8.26 ± 0.55%) and MDI groups (8.30 ± 0.53%). All subsequent A1C values showed significant (p < 0.05) treatment group differences favoring SAP therapy. Compared with the MDI group, subjects in the SAP group were more likely to meet age-specific A1C targets and had lower AUC values for hyperglycemia with no increased risk of hypoglycemia. Glucose variability improved in the SAP group compared to the MDI group. Children wore CGM sensors more often and were more likely to reach age-specific A1C targets than adolescents. CONCLUSIONS: SAP therapy allows both children and adolescents with marginally or inadequately controlled type 1 diabetes to reduce A1C values, hyperglycemic excursions, and glycemic variability in a rapid, sustainable, and safe manner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894 · cited 2×
“The sensor-augmented pump therapy for A1C reduction (STAR 3) study (6) examined the effectiveness of switching directly from MDI and SMBG to a system that augments insulin pump therapy with continuous glucose sensors (termed sensor-augmented pump therapy or SAP).”
ResultZiegler, R., Heidtmann, B., Hilgard, D., Hofer, S., Rosenbauer, J., Holl, R., & DPV-Wiss-Initiative, F. T. (2011) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2010.00650.x · Cited by 334 · cited 1×
“A recent study of children and adolescents showed a strong relationship between SMBG frequency and improved metabolic control (9), and a similar dose effect of CGM sensor wear on A1C reduction was shown in the interventional STAR 3 study (6) and a separate observational study (10).”
ResultEffectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Cited by
Standards of medical care in diabetes—2013
American Diabetes Association (2013) · Diabetes Care · doi:10.2337/dc13-s011 · Cited by 4,369
“A trial comparing CGM plus insulin pump to SMBG plus multiple injections of insulin in adults and children with type 1 diabetes showed significantly greater improvements in A1C with “sensoraugmented pump” therapy (68,69), but this trial did not isolate the effect of CGM itself.”
BackgroundStandards of Medical Care in Diabetes—2012
(2012) · Diabetes Care · doi:10.2337/dc12-s011 · Cited by 2,240
Chiang, J. L., Maahs, D. M., Garvey, K. C., Hood, K. K., Laffel, L. M., Weinzimer, S. A., Wolfsdorf, J. I., & Schatz, D. (2018) · Diabetes Care · doi:10.2337/dci18-0023 · Cited by 509
Self-citationGrunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Continuous Glucose Monitoring Systems: A Review
Vashist, S. (2013) · Diagnostics · doi:10.3390/diagnostics3040385 · Cited by 261
Metadata
- Authors
- Slover, R. H., Welsh, J. B., Criego, A., Weinzimer, S. A., Willi, S. M., Wood, M. A., & Tamborlane, W. V.
- Venue
- Pediatric Diabetes
- Publisher
- Hindawi Limited
- Published
- 2011-07-03
- Volume
- 13
- Issue
- 1
- Pages
- 6-11
- ISSN
- 1399-543X (ISSN-L)
- OpenAlex
- W2160499117
- Cited by
- 135
- References
- 5
- FWCI
- 9.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effectiveness of sensor-augmented pump therapy in children and adolescents with type 1 diabetes in the STAR 3 study. https://app.cochat.ai/papers/10.1111/j.1399-5448.2011.00793.x
- The paper
- Slover, R. H., Welsh, J. B., Criego, A., Weinzimer, S. A., Willi, S. M., Wood, M. A., & Tamborlane, W. V. (2012). Effectiveness of sensor-augmented pump therapy in children and adolescents with type 1 diabetes in the STAR 3 study. Pediatric Diabetes. https://doi.org/10.1111/j.1399-5448.2011.00793.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.