Atelectasis and lung function in the postoperative period
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Thirteen patients with healthy hearts and lungs, and with a mean age of 68 years, who were scheduled for lower abdominal surgery during isoflurane anaesthesia with muscular paralysis, were investigated with arterial blood gases, spirometry, pulmonary x‐ray and computed tomography (CT) of the chest before and during anaesthesia, as well as during the first 4 postoperative days. Before anaesthesia, lung function and gas exchange were normal in all patients. Pulmonary x‐ray and CT scans of the lungs were also normal. During anaesthesia, 6 of 13 patients developed atelectasis (mean 1.0% of intrathoracic transverse area in all patients). Two hours postoperatively, 11 of 13 patients had atelectasis and the mean atelectatic area was 1.8%. Pao 2 was significantly reduced by 2.1 kPa to 9.8 kPa. On the first postoperative day, the mean atelectasis was unaltered (1.8%). None of the atelectasis found on CT scanning could be detected on standard pulmonary x‐ray. Forced vital capacity (FVC) and forced expired volume in 1 s (FEV 1) were significantly decreased to 2/3 of preoperative level. Pao 2 was significantly reduced to less than 80% of the preoperative level (mean 9.4 kPa). There were significant correlations between the atelectatic area and the impairment in FVC, FEV 1, and Pao 2. Spirometry and blood gases improved during the succeeding postoperative days, and atelectasis decreased. No patient suffered from pulmonary complications, as judged from clinical criteria and pulmonary x‐ray, in contrast to the findings of atelectasis in 85% of the patients by computed tomography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Risk factors for postoperative pneumonia
Garibaldi, R. A., Britt, M. R., Coleman, M. L., Reading, J. C., & Pace, N. L. (1981) · The American Journal of Medicine · doi:10.1016/0002-9343(81)90595-7 · Cited by 485
Airway closure as a function of age
Anthonisen, N. R., Danson, J., Robertson, P. C., & Ross, W. R. D. (1969) · Respiration Physiology · doi:10.1016/0034-5687(69)90044-9 · Cited by 321
A prospective survey of the incidence of postoperative pulmonary complications
Wightman, J. A. K. (1968) · Journal of British Surgery · doi:10.1002/bjs.1800550202 · Cited by 294
INFLUENCE OF AGE ON ATELECTASIS FORMATION AND GAS EXCHANGE IMPAIRMENT DURING GENERAL ANAESTHESIA
GUNNARSSON, L., TOKICS, L., GUSTAVSSON, H., & HEDENSTIERNA, G. (1991) · British Journal of Anaesthesia · doi:10.1093/bja/66.4.423 · Cited by 253
Self-citationAtelectasis during anaesthesia and in the postoperative period
STRANDBERG, Å., TOKICS, L., BRISMAR, B., LUNDQUIST, H., & HEDENSTIERNA, G. (1986) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1986.tb02387.x · Cited by 240
Self-citationMüller, N. L., VOLGYESI, G. A., Becker, L. B., Bryan, M. H., & Bryan, A. C. (1979) · Journal of Applied Physiology · doi:10.1152/jappl.1979.47.2.279 · Cited by 142
Cited by
Squadrone, V., Coha, M., Cerutti, E., Schellino, M. M., Biolino, P., Occella, P., Belloni, G., Vilianis, G., Fiore, G., Cavallo, F., et al. (2005) · JAMA · doi:10.1001/jama.293.5.589 · Cited by 667
Pulmonary Atelectasis: A Pathogenic Perioperative Entity
Duggan, M., Kavanagh, B. P., & Warltier, D. C. (2005) · Anesthesiology · doi:10.1097/00000542-200504000-00021 · Cited by 645
Pereira, S. M., Tucci, M. R., Morais, C. C. A., Simões, C. M., Tonelotto, B. F. F., Pompeo, M. S., Kay, F. U., Pelosi, P., Vieira, J. E., & Amato, M. B. P. (2018) · Anesthesiology · doi:10.1097/aln.0000000000002435 · Cited by 307
Westerdahl, E., Lindmark, B., Eriksson, T., Friberg, Ö., Hedenstierna, G., & Tenling, A. (2005) · Chest · doi:10.1378/chest.128.5.3482 · Cited by 234
Self-citationThe effects of anesthesia and muscle paralysis on the respiratory system
Hedenstierna, G., & Edmark, L. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2761-7 · Cited by 229
Self-citationAtelectasis and perioperative pulmonary complications in high-risk patients
Tusman, G., Böhm, S. H., Warner, D. O., & Sprung, J. (2012) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e32834dd1eb · Cited by 211
“Atelectasis is seldom visible on chest radiograms, but rather requires chest computed tomography for detection, so it is frequently underappreciated [4,14,36,44].”
BackgroundThe Effect of Increased Fio2 Before Tracheal Extubation on Postoperative Atelectasis
Benoît, Z., Wicky, S., Fischer, J.-F., Frascarolo, P., Chapuis, C., Spahn, D. R., & Magnusson, L. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200212000-00058 · Cited by 193
“A vital capacity (VC) maneuver (manual inflation of the intubated patient’s lungs to 40 cm H2O for 15 s) nearly eliminates atelectasis (8), which recurs within 5 minutes if the patient is ventilated with 100% oxygen (11).”
BackgroundQadan, M. (2009) · Archives of Surgery · doi:10.1001/archsurg.2009.1 · Cited by 189
Low intraoperative tidal volume ventilation with minimal PEEP is associated with increased mortality
Levin, M. A., McCormick, P. J., Lin, H. M., Hosseinian, L., & Fischer, G. W. (2014) · British Journal of Anaesthesia · doi:10.1093/bja/aeu054 · Cited by 187
Lung Ultrasonography for the Assessment of Perioperative Atelectasis: A Pilot Feasibility Study
Monastesse, A., Girard, F., Massicotte, N., Chartrand-Lefebvre, C., & Girard, M. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001603 · Cited by 181
Akça, O., Podolsky, A., Eisenhuber, E., Panzer, O., Hetz, H., Lampl, K., Lackner, F. X., Wittmann, K., Grabenwoeger, F., Kurz, A., et al. (1999) · Anesthesiology · doi:10.1097/00000542-199910000-00019 · Cited by 173
“The sample size for this study was based on atelectasis rates cited in previous studies.(1,11) These data suggested that a power of 95% for detecting a 50% difference in atelectasis at an a level of 0.”
MethodResultOxygen and anesthesia: what lung do we deliver to the post‐operative ward?
HEDENSTIERNA, G. (2012) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2012.02689.x · Cited by 85
“On the fourth day after surgery, there was a decrease to about 20–25% of the atelectasis during anesthesia.(63) It is also interesting to notice that very preliminary data suggest a remaining low thoracic volume still an hour, perhaps longer, after anesthesia.”
BackgroundSelf-citation
Metadata
- Authors
- Lindberg, P., Gunnarsson, L., Tokics, L., Secher, E., Lundquist, H., Brismar, B., & Hedenstierna, G.
- Venue
- Acta Anaesthesiologica Scandinavica
- Publisher
- Wiley
- Published
- 1992-08
- Volume
- 36
- Issue
- 6
- Pages
- 546-553
- ISSN
- 0001-5172 (ISSN-L)
- 1399-6576
- OpenAlex
- W2059160953
- Cited by
- 264
- References
- 6
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.