CoChat

Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output

Zoremba, N., Bickenbach, J., Krauss, B., Rossaint, R., Kuhlen, R., Schälte, G. · 2007 · Acta Anaesthesiologica Scandinavica
Cited by 105

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Aim: To compare a new method of non‐invasive determination of cardiac output based on electrical velocimetry (EV‐CO) with invasive thermodilution methods. Methods: Fifty critically ill patients were enrolled into the study. EV‐CO was compared with cardiac output measured by a pulmonary artery catheter (PA‐CO) in one group (n= 25) and by a femoral artery catheter (PiCCO‐CO) in a second group (n= 25), by simultaneous measurements. Standard electrocardiography electrodes were used for non‐invasive measurements, and EV‐CO was calculated using the Bernstein–Osypka equation. The invasive measurements of PA‐CO and PiCCO‐CO were made by the injection of iced 0.9% saline and the recording of thermodilution curves. Results: The precision values of EV‐CO, PA‐CO and PiCCO‐CO measurements were ± 0.46 [95% confidence interval (95% CI), ± 0.06], ± 0.57 (95% CI, ± 0.09) and ± 0.48 l/min (95% CI, ± 0.08 l/min), respectively. The mean differences between EV‐CO and PA‐CO or PiCCO‐CO were –0.05 ± 0.71 and 0.22 ± 0.78 l/min, respectively. The lower and upper limits of agreement for the comparison of EV‐CO with PA‐CO were −1.47 and 1.37 l/min (95% CI, ± 0.25 l/min), respectively. In the comparison of EV‐CO and PiCCO‐CO, lower and upper limits of –1.34 and 1.78 l/min (95% CI, ± 0.27 l/min) were found. The percentage errors between EV‐CO and PA‐CO or PiCCO‐CO were 26.5% and 26.4%, respectively. Conclusions: The values of cardiac output were statistically comparable between the groups. Therefore, electrical velocimetry is a suitable method to evaluate haemodynamic variables with clinically acceptable accuracy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1399-6576.2007.01445.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 105

Metadata

Authors
Zoremba, N., Bickenbach, J., Krauss, B., Rossaint, R., Kuhlen, R., & Schälte, G.
Venue
Acta Anaesthesiologica Scandinavica
Publisher
Wiley
Published
2007-10-18
Volume
51
Issue
10
Pages
1314-1319
ISSN
  • 0001-5172 (ISSN-L)
  • 1399-6576
OpenAlex
W2149297659
Cited by
105
References
1
FWCI
3.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output. https://app.cochat.ai/papers/10.1111/j.1399-6576.2007.01445.x
The paper
Zoremba, N., Bickenbach, J., Krauss, B., Rossaint, R., Kuhlen, R., & Schälte, G. (2007). Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output. Acta Anaesthesiologica Scandinavica. https://doi.org/10.1111/j.1399-6576.2007.01445.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.