Video‐laryngoscopes in the adult airway management: a topical review of the literature
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
The aim of the present paper is to review the literature regarding video‐laryngoscopes (Storz V‐Mac and C‐Mac, Glidescope, McGrath, Pentax‐Airway Scope, Airtraq and Bullard) and discuss their clinical role in airway management. Video‐laryngoscopes are new intubation devices, which provide an indirect view of the upper airway. In difficult airway management, they improve Cormack–Lehane grade and achieve the same or a higher intubation success rate in less time, compared with direct laryngoscopes. Despite the very good visualization of the glottis, the insertion and advancement of the endotracheal tube with video‐laryngoscopes may occasionally fail. Each particular device's features may offer advantages or disadvantages, depending on the situation the anaesthesiologist has to deal with. So far, there is inconclusive evidence indicating that video‐laryngoscopy should replace direct laryngoscopy in patients with normal or difficult airways.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adverse Respiratory Events in Anesthesia: A Closed Claims Analysis
Caplan, R. A., Posner, K. L., Ward, R. J., & Cheney, F. W. (1990) · Anesthesiology · doi:10.1097/00000542-199005000-00010 · Cited by 1,060
Shiga, T., Wajima, Z., Inoue, T., & Sakamoto, A. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00027 · Cited by 902
The airway: problems and predictions in 18,500 patients
Rose, D. K., & Cohen, M. M. (1994) · Canadian Journal of Anaesthesia · doi:10.1007/bf03009858 · Cited by 645
The unanticipated difficult airway with recommendations for management
Crosby, E. T., Cooper, R. M., Douglas, M. J., Doyle, D. J., Hung, O. R., Labrecque, P., Muir, H., Murphy, M. F., Preston, R. P., Rose, D. K., et al. (1998) · Canadian Journal of Anaesthesia · doi:10.1007/bf03012147 · Cited by 615
Early clinical experience with a new videolaryngoscope (GlideScope®) in 728 patients
Cooper, R. M., Pacey, J. A., Bishop, M. J., & McCluskey, S. A. (2005) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03027728 · Cited by 562
Konrad, C., Schupfer, G., Wietlisbach, M., & Gerber, H. (1998) · Anesthesia & Analgesia · doi:10.1213/00000539-199803000-00037 · Cited by 545
The GlideScope® Video Laryngoscope: randomized clinical trial in 200 patients
Sun, D. A., Warriner, C. B., Parsons, D. G., Klein, R., Umedaly, H. S., & Moult, M. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei041 · Cited by 359
Lee, A., Fan, L. T. Y., Gin, T., Karmakar, M. K., & Ngan Kee, W. D. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000217211.12232.55 · Cited by 319
A new practical classification of laryngeal view
Cook, T. M. (2000) · Anaesthesia · doi:10.1046/j.1365-2044.2000.01270.x · Cited by 252
Complications associated with the use of the GlideScope® videolaryngoscope
Cooper, R. M. (2007) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03021900 · Cited by 238
Turkstra, T. P., Craen, R. A., Pelz, D. M., & Gelb, A. W. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000166975.38649.27 · Cited by 238
Nouruzi-Sedeh, P., Schumann, M., & Groeben, H. (2009) · Anesthesiology · doi:10.1097/aln.0b013e318190b6a7 · Cited by 238
Malik, M. A., Maharaj, C. H., Harte, B. H., & Laffey, J. G. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen231 · Cited by 229
Jungbauer, A., Schumann, M., Brunkhorst, V., Börgers, A., & Groeben, H. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep013 · Cited by 209
Comparison of direct and video-assisted views of the larynx during routine intubation
Kaplan, M. B., Hagberg, C. A., Ward, D. S., Brambrink, A., Chhibber, A. K., Heidegger, T., Lozada, L., Ovassapian, A., Parsons, D., Ramsay, J., et al. (2006) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2006.01.002 · Cited by 203
Maharaj, C. H., Buckley, E., Harte, B. H., & Laffey, J. G. (2007) · Anesthesiology · doi:10.1097/01.anes.0000267529.71756.f0 · Cited by 192
Robitaille, A., Williams, S. R., Tremblay, M.-H., Guilbert, F., Thériault, M., & Drolet, P. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318161769e · Cited by 191
Enomoto, Y., Asai, T., Arai, T., Kamishima, K., & Okuda, Y. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen002 · Cited by 189
Use of the Pentax-AWS® in 293 Patients with Difficult Airways
Asai, T., Liu, E. H., Matsumoto, S., Hirabayashi, Y., Seo, N., Suzuki, A., Toi, T., Yasumoto, K., & Okuda, Y. (2009) · Anesthesiology · doi:10.1097/aln.0b013e31819c45e5 · Cited by 186
Mihai, R., Blair, E., Kay, H., & Cook, T. M. (2008) · Anaesthesia · doi:10.1111/j.1365-2044.2008.05489.x · Cited by 179
A new video laryngoscope—an aid to intubation and teaching
Kaplan, M. B., Ward, D. S., & Berci, G. (2002) · Journal of Clinical Anesthesia · doi:10.1016/s0952-8180(02)00457-9 · Cited by 164
Malik, M. A., Subramaniam, R., Maharaj, C. H., Harte, B. H., & Laffey, J. G. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep266 · Cited by 163
Ndoko, S. K., Amathieu, R., Tual, L., Polliand, C., Kamoun, W., El Housseini, L., Champault, G., & Dhonneur, G. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aem346 · Cited by 162
Maassen, R. L. J. G., Lee, R. A., Hermans, B. J. E., Marcus, M. A. E., & van Zundert, A. A. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181b7303a · Cited by 158
Video-assisted instruction improves the success rate for tracheal intubation by novices
Howard-Quijano, K. J., Huang, Y. M., Matevosian, R., Kaplan, M. B., & Steadman, R. H. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen211 · Cited by 157
Lim, T. J., Lim, Y., & Liu, E. H. C. (2005) · Anaesthesia · doi:10.1111/j.1365-2044.2004.04038.x · Cited by 152
The use of the GlideScope ® for tracheal intubation in patients with ankylosing spondylitis
Lai, H. Y., Chen, I. H., Chen, A., Hwang, F. Y., & Lee, Y. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael133 · Cited by 146
van Zundert, A. A. J., Maassen, R. L. J. G., Lee, R. A., Willems, R., Timmerman, M., Siemonsma, M. A., Buise, M. P., & Wiepking, M. E. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181ae39db · Cited by 140
Malik, M. A., O’Donoghue, C., Carney, J., Maharaj, C. H., Harte, B. H., & Laffey, J. G. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen342 · Cited by 124
The Pentax‐AWS ® rigid indirect video laryngoscope: clinical assessment of performance in 320 cases*
Suzuki, A., Toyama, Y., Katsumi, N., Kunisawa, T., Sasaki, R., Hirota, K., Henderson, J. J., & Iwasaki, H. (2008) · Anaesthesia · doi:10.1111/j.1365-2044.2008.05452.x · Cited by 119
Turkstra, T. P., Pelz, D. M., & Jones, P. M. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181a8649f · Cited by 103
Review of video laryngoscopy and rigid fiberoptic laryngoscopy
Pott, L. M., & Murray, W. B. (2008) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e3283184227 · Cited by 102
Burkle, C. M., Walsh, M. T., Harrison, B. A., Curry, T. B., & Rose, S. H. (2005) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03015776 · Cited by 100
Maruyama, K., Yamada, T., Kawakami, R., Kamata, T., Yokochi, M., & Hara, K. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem313 · Cited by 99
Walker, L., Brampton, W., Halai, M., HOY, C. J., Lee, E., Scott, I., & McLernon, D. J. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep191 · Cited by 93
Turkstra, T. P., Harle, C. C., Armstrong, K., Armstrong, P. M., Cherry, R. A., Hoogstra, J., & Jones, P. M. (2007) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03026792 · Cited by 91
Videolaryngoscopy in the management of the difficult airway: a comparison with the Macintosh blade
Stroumpoulis, K., Pagoulatou, A., Βιολάρη, Μ., Ikonomou, I., Kalantzi, N., Kastrinaki, K., Xanthos, T. T., & Michaloliakou, C. (2009) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32831c84d1 · Cited by 89
Self-citationMaruyama, K., Yamada, T., Kawakami, R., & Hara, K. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen207 · Cited by 87
Forces Applied to the Maxillary Incisors During Video-Assisted Intubation
Lee, R. A., van Zundert, A. A. J., Maassen, R. L. J. G., Willems, R., Beeke, L. P., Schaaper, J. N., van Dobbelsteen, J., & Wieringa, P. A. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31818d1904 · Cited by 78
Cohn, A. I., & Zornow, M. H. (1995) · Anesthesia & Analgesia · doi:10.1097/00000539-199512000-00027 · Cited by 77
Liu, E. H. C., Goy, R., Tan, B. H., & Asai, T. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep164 · Cited by 74
Xue, F., Zhang, G. H., Li, X. Y., et al. (2007) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2006.11.004 · Cited by 72
The clinical assessment of Glidescope in orotracheal intubation under general anesthesia.
Xue, F., ZHANG, G. H., Liu, J., Li, X. Y., Yang, Q., Xu, Y., & Li, C. W. (2007) · PubMed · Cited by 71
Perforation of the soft palate using the GlideScope® videolaryngoscope
Cross, P., Cytryn, J., & Cheng, K. K. (2007) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03022329 · Cited by 67
Nasim, S., Maharaj, C. H., Malik, M. A., Donnell, J. O., Higgins, B. D., & Laffey, J. G. (2009) · BMC Emergency Medicine · doi:10.1186/1471-227x-9-9 · Cited by 64
Malik, M. A., Subramaniam, R., Churasia, S., Maharaj, C. H., Harte, B. H., & Laffey, J. G. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep056 · Cited by 61
An evaluation of the GlideScope®, a new video laryngoscope for difficult airways: a manikin study
Benjamin, F., Boon, D., & French, R. A. (2006) · European Journal of Anaesthesiology · doi:10.1017/s0265021506000147 · Cited by 60
Takenaka, I., Aoyama, K., Iwagaki, T., Ishimura, H., Takenaka, Y., & Kadoya, T. (2009) · Anesthesiology · doi:10.1097/aln.0b013e31819fb44a · Cited by 52
Airway Scope: early clinical experience in 405 patients
Hirabayashi, Y., & Seo, N. (2008) · Journal of Anesthesia · doi:10.1007/s00540-007-0580-4 · Cited by 51
Tan, B. H., Liu, E. H. C., Lim, R. T. C., Liow, M. H. L., & Goy, R. (2009) · Anaesthesia · doi:10.1111/j.1365-2044.2008.05753.x · Cited by 46
Lim, H. C., & Goh, S. H. (2008) · European Journal of Emergency Medicine · doi:10.1097/mej.0b013e328303e1c6 · Cited by 45
Nasim, S., Maharaj, C. H., Butt, I., Malik, M. A., Donnell, J. O., Higgins, B. D., Harte, B. H., & Laffey, J. G. (2009) · BMC Emergency Medicine · doi:10.1186/1471-227x-9-2 · Cited by 43
Voluntary reporting system in anaesthesia: is there a link between undesirable and critical events?
Boëlle, P., Garnerin, P., Clergue, F., Sicard, J.-F., & Bonnet, F. J. (2000) · BMJ Quality & Safety · doi:10.1136/qhc.9.4.203 · Cited by 43
O’Leary, A. M., Sandison, M. R., Myneni, N., Cirilla, D. J., Roberts, K. W. S., & Deane, G. (2008) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2008.02.004 · Cited by 41
Komatsu, R., Kamata, K., Hoshi, I., Sessler, D. I., & Ozaki, M. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen288 · Cited by 40
The GlideScope Ranger® video laryngoscope can be useful in airway management of entrapped patients
Nakstad, A. R., & Sandberg, M. (2009) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2009.02094.x · Cited by 37
(2006) · Survey of Anesthesiology · doi:10.1097/01.sa.0000203214.49672.a6 · Cited by 3
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., & Smith, A. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011136.pub2 · Cited by 374
Myatra, S. N., Shah, A., Kundra, P., Patwa, A., Ramkumar, V., Divatia, J. V., Raveendra, U. S., Shetty, S. R., Ahmed, S. M., Doctor, J. R., et al. (2016) · Indian Journal of Anaesthesia · doi:10.4103/0019-5049.195481 · Cited by 294
Failed tracheal intubation in obstetric anaesthesia: 2 yr national case–control study in the UK
Quinn, A. C., Milne, D., Columb, M., Gorton, H., & Knight, M. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aes320 · Cited by 267
Sakles, J. C., Mosier, J., Chiu, S., Cosentino, M., & Kalin, L. (2012) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2012.03.031 · Cited by 192
Metadata
- Authors
- NIFOROPOULOU, P., PANTAZOPOULOS, I., DEMESTIHA, T., KOUDOUNA, E., & XANTHOS, T.
- Venue
- Acta Anaesthesiologica Scandinavica
- Publisher
- Wiley
- Published
- 2010-07-28
- Volume
- 54
- Issue
- 9
- Pages
- 1050-1061
- ISSN
- 0001-5172 (ISSN-L)
- 1399-6576
- OpenAlex
- W2133167770
- Cited by
- 316
- References
- 58
- FWCI
- 27.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.