Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 286

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

FLUID MECHANICS OF ARTIFICIAL HEART VALVES

Open access
Dasi, Lakshmi P, Simon, Helene A, Sucosky, Philippe, Yoganathan, Ajit P·2009·Clinical and Experimental Pharmacology and Physiology

Abstract

SUMMARY: Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged‐ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue‐based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non‐physiological blood flow patterns. In the present review, we provide a bird's‐eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life‐long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10–15 years of implantation. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1440-1681.2008.05099.x

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 286

Metadata

Authors
Dasi, L. P., Simon, H. A., Sucosky, P., & Yoganathan, A. P.
Venue
Clinical and Experimental Pharmacology and Physiology
Publisher
Wiley
Published
2009-01-27
Volume
36
Issue
2
Pages
225-237
ISSN
  • 0305-1870 (ISSN-L)
  • 1440-1681
OpenAlex
W2002339668
Cited by
286
References
23
FWCI
8.30
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: FLUID MECHANICS OF ARTIFICIAL HEART VALVES. https://app.cochat.ai/papers/10.1111/j.1440-1681.2008.05099.x
The paper
Dasi, L. P., Simon, H. A., Sucosky, P., & Yoganathan, A. P. (2009). FLUID MECHANICS OF ARTIFICIAL HEART VALVES. Clinical and Experimental Pharmacology and Physiology. https://doi.org/10.1111/j.1440-1681.2008.05099.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.