The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Double balloon enteroscopy and capsule endoscopy for obscure gastrointestinal bleeding: An updated meta‐analysis
Abstract
Background and Aim: Uncertainty remains about the best test to evaluate patients with obscure gastrointestinal bleeding (OGIB). Previous meta‐analyses demonstrated similar diagnostic yields with capsule endoscopy (CE) and double balloon enteroscopy (DBE) but relied primarily on data from abstracts and were not limited to bleeding patients. Many studies have since been published. Therefore, we performed a new meta‐analysis comparing CE and DBE focused specifically on OGIB. Methods: A comprehensive literature search was performed of comparative studies using both CE and DBE in patients with OGIB. Data were extracted and analyzed to determine the weighted pooled diagnostic yields of each method and the odds ratio for the successful localization of a bleeding source. Results: Ten eligible studies were identified. The pooled diagnostic yield for CE was 62% (95% confidence interval [CI] 47.3–76.1) and for DBE was 56% (95% CI 48.9–62.1), with an odds ratio for CE compared with DBE of 1.39 (95% CI 0.88–2.20; P = 0.16). Subgroup analysis demonstrated the yield for DBE performed after a previously positive CE was 75.0% (95% CI 60.1–90.0), with the odds ratio for successful diagnosis with DBE after a positive CE compared with DBE in all patients of 1.79 (95% CI 1.09–2.96; P = 0.02). In contrast, the yield for DBE after a previously negative CE was only 27.5% (95% CI 16.7–37.8). Conclusions: Capsule endoscopy and double balloon enteroscopy provide similar diagnostic yields in patients with OGIB. However, the diagnostic yield of DBE is significantly higher when performed in patients with a positive CE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066
Total enteroscopy with a nonsurgical steerable double-balloon method
Yamamoto, H., Sekine, Y., Sato, Y., Higashizawa, T., Miyata, T., Iino, S., Ido, K., & Sugano, K. (2001) · Gastrointestinal Endoscopy · doi:10.1067/mge.2001.112181 · Cited by 1,289
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
Pennazio, M., Santucci, R., Rondonotti, E., Abbiati, C., Beccari, G., Rossini, F. P., & De Franchis, R. (2004) · Gastroenterology · doi:10.1053/j.gastro.2003.11.057 · Cited by 918
Raju, G. S., Gerson, L., Das, A., & Lewis, B. (2007) · Gastroenterology · doi:10.1053/j.gastro.2007.06.007 · Cited by 528
Kameda, N., Higuchi, K., Shiba, M., et al. (2008) · Journal of Gastroenterology · doi:10.1007/s00535-008-2182-9 · Cited by 124
Cost-effectiveness analysis of management strategies for obscure GI bleeding
Gerson, L. B., & Kamal, A. (2008) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2008.01.035 · Cited by 122
Cited by
Pennazio, M., Spada, C., Eliakim, R., Keuchel, M., May, A., Mulder, C., Rondonotti, E., Adler, S., Albert, J., Baltes, P., et al. (2015) · Endoscopy · doi:10.1055/s-0034-1391855 · Cited by 894
ACG Clinical Guideline: Diagnosis and Management of Small Bowel Bleeding
Gerson, L. B., Fidler, J. L., Cave, D. R., & Leighton, J. A. (2015) · American Journal of Gastroenterology · doi:10.1038/ajg.2015.246 · Cited by 719
Panes, J., Bouhnik, Y., Reinisch, W., Stoker, J., Taylor, S. A., Baumgart, D. C., Danese, S., Halligan, S., Marincek, B., Matos, C., et al. (2013) · Journal of Crohn's and Colitis · doi:10.1016/j.crohns.2013.02.020 · Cited by 668
Clinical Practice Guidelines for the Use of Video Capsule Endoscopy
Enns, R. A., Hookey, L., Armstrong, D., Bernstein, C. N., Heitman, S. J., Teshima, C., Leontiadis, G. I., Tse, F., & Sadowski, D. (2017) · Gastroenterology · doi:10.1053/j.gastro.2016.12.032 · Cited by 400
Self-citationPennazio, M., Rondonotti, E., Despott, E. J., Dray, X., Keuchel, M., Moreels, T., Sanders, D. S., Spada, C., Carretero, C., Cortegoso Valdivia, P., et al. (2023) · Endoscopy · doi:10.1055/a-1973-3796 · Cited by 331
Metadata
- Authors
- Teshima, C. W., Kuipers, E. J., van Zanten, S. V., & Mensink, P. B. F.
- Venue
- Journal of Gastroenterology and Hepatology
- Publisher
- Wiley
- Published
- 2011-04-13
- Volume
- 26
- Issue
- 5
- Pages
- 796-801
- ISSN
- 0815-9319 (ISSN-L)
- 1440-1746
- OpenAlex
- W2168130757
- Cited by
- 295
- References
- 13
- FWCI
- 11.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Double balloon enteroscopy and capsule endoscopy for obscure gastrointestinal bleeding: An updated meta‐analysis. https://app.cochat.ai/papers/10.1111/j.1440-1746.2010.06530.x
- The paper
- Teshima, C. W., Kuipers, E. J., van Zanten, S. V., & Mensink, P. B. F. (2011). Double balloon enteroscopy and capsule endoscopy for obscure gastrointestinal bleeding: An updated meta‐analysis. Journal of Gastroenterology and Hepatology. https://doi.org/10.1111/j.1440-1746.2010.06530.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.