Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 295

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Double balloon enteroscopy and capsule endoscopy for obscure gastrointestinal bleeding: An updated meta‐analysis

Teshima, Christopher W, Kuipers, Ernst J, van Zanten, Sander Veldhuyzen, Mensink, Peter B F·2011·Journal of Gastroenterology and Hepatology

Abstract

Background and Aim: Uncertainty remains about the best test to evaluate patients with obscure gastrointestinal bleeding (OGIB). Previous meta‐analyses demonstrated similar diagnostic yields with capsule endoscopy (CE) and double balloon enteroscopy (DBE) but relied primarily on data from abstracts and were not limited to bleeding patients. Many studies have since been published. Therefore, we performed a new meta‐analysis comparing CE and DBE focused specifically on OGIB. Methods: A comprehensive literature search was performed of comparative studies using both CE and DBE in patients with OGIB. Data were extracted and analyzed to determine the weighted pooled diagnostic yields of each method and the odds ratio for the successful localization of a bleeding source. Results: Ten eligible studies were identified. The pooled diagnostic yield for CE was 62% (95% confidence interval [CI] 47.3–76.1) and for DBE was 56% (95% CI 48.9–62.1), with an odds ratio for CE compared with DBE of 1.39 (95% CI 0.88–2.20; P = 0.16). Subgroup analysis demonstrated the yield for DBE performed after a previously positive CE was 75.0% (95% CI 60.1–90.0), with the odds ratio for successful diagnosis with DBE after a positive CE compared with DBE in all patients of 1.79 (95% CI 1.09–2.96; P = 0.02). In contrast, the yield for DBE after a previously negative CE was only 27.5% (95% CI 16.7–37.8). Conclusions: Capsule endoscopy and double balloon enteroscopy provide similar diagnostic yields in patients with OGIB. However, the diagnostic yield of DBE is significantly higher when performed in patients with a positive CE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1440-1746.2010.06530.x

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 295

Metadata

Authors
Teshima, C. W., Kuipers, E. J., van Zanten, S. V., & Mensink, P. B. F.
Venue
Journal of Gastroenterology and Hepatology
Publisher
Wiley
Published
2011-04-13
Volume
26
Issue
5
Pages
796-801
ISSN
  • 0815-9319 (ISSN-L)
  • 1440-1746
OpenAlex
W2168130757
Cited by
295
References
13
FWCI
11.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Double balloon enteroscopy and capsule endoscopy for obscure gastrointestinal bleeding: An updated meta‐analysis. https://app.cochat.ai/papers/10.1111/j.1440-1746.2010.06530.x
The paper
Teshima, C. W., Kuipers, E. J., van Zanten, S. V., & Mensink, P. B. F. (2011). Double balloon enteroscopy and capsule endoscopy for obscure gastrointestinal bleeding: An updated meta‐analysis. Journal of Gastroenterology and Hepatology. https://doi.org/10.1111/j.1440-1746.2010.06530.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.