CoChat

Enhancement of long‐range EEG coherence by synchronous bifocal transcranial magnetic stimulation

Open access
Plewnia, Christian, Rilk, Albrecht J., Soekadar, Surjo R., Arfeller, Carola, Huber, Heiko S., Sauseng, Paul, Hummel, Friedhelm, Gerloff, Christian · 2008 · European Journal of Neuroscience
Cited by 56

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Interregional coupling of distant brain regions can be measured by electroencephalographic (EEG) coherence reflecting the spatial–temporal correlation between two oscillatory signals. It has been suggested that this coherence in activity is a signature of functional integration of multimodal neuronal networks. Repetitive transcranial magnetic stimulation (rTMS) is a well‐established technique for non‐invasive cortical stimulation. Its modulating effects outlast the train of stimulation and affect behavior. In the present study, we tested the hypothesis that cortico‐cortical coherence between distant brain areas can be selectively enhanced by synchronous bifocal rTMS. Cortico‐cortical coherence was assessed in 16 healthy human subjects before and after three trains of synchronous high‐frequency (10 Hz) rTMS to the left primary motor cortex and the visual cortex at the occipital pole simultaneously. Stimulation of the left M1 alone served as the control condition. Coherence and spectral power were measured between these areas on the stimulated and the homologue contralateral side. Synchronous bifocal rTMS induced an increase of interregional coupling in the alpha and lower beta band on the stimulated side without effects on spectral power. These data indicate that synchronous bifocal rTMS is a feasible technique for selective modulation of interregional EEG coherence. Furthermore, they raise the hypothesis that interventional enhancement of long‐range coherence may effectively modulate interregional integration with behavioral consequences.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1460-9568.2008.06124.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 56

Metadata

Authors
Plewnia, C., Rilk, A. J., Soekadar, S. R., Arfeller, C., Huber, H. S., Sauseng, P., Hummel, F., & Gerloff, C.
Venue
European Journal of Neuroscience
Publisher
Wiley
Published
2008-03
Volume
27
Issue
6
Pages
1577-1583
ISSN
  • 0953-816X (ISSN-L)
  • 1460-9568
OpenAlex
W2002231386
Cited by
56
References
4
FWCI
2.06
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enhancement of long‐range EEG coherence by synchronous bifocal transcranial magnetic stimulation. https://app.cochat.ai/papers/10.1111/j.1460-9568.2008.06124.x
The paper
Plewnia, C., Rilk, A. J., Soekadar, S. R., Arfeller, C., Huber, H. S., Sauseng, P., Hummel, F., & Gerloff, C. (2008). Enhancement of long‐range EEG coherence by synchronous bifocal transcranial magnetic stimulation. European Journal of Neuroscience. https://doi.org/10.1111/j.1460-9568.2008.06124.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.