Comparison of electrical velocimetry and transpulmonary thermodilution for measuring cardiac output in piglets
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Summary: Background: Monitoring of cardiovascular function is essential during major pediatric and pediatric cardiac surgery. Invasive monitoring of cardiac output (CO) and oxygen delivery is expensive and sometimes associated with adverse events. Therefore, we investigated the accuracy of a new noninvasive CO monitoring device using electrical velocimetry (EV) in comparison with the more invasive transpulmonary thermodilution (TPTD) method. Methods: In five fasted, anesthetized and mechanically ventilated piglets, CO was measured simultaneously using EV and TPTD under normal conditions, volume loading, inotropic support and exsanguination. Results: In five piglets, 169 measurements could be performed. The correlations between EV–CO and TPTD–CO were significant for absolute values (P < 0.0001, r = 0.82) and relative changes from baseline (P < 0.0001, r = 0.93). The receiver operating characteristic (ROC) curve analysis of the relative changes of the EV–CO values in relation to the first EV–CO measurement showed a sensitivity of 91% and specificity of 94% (AUC 0.974, 95% CI 0.96–0.99). Changes in TPTD–CO greater than 15% lead to a change of EV–CO in the same direction in 93%. Bland–Altman analysis showed a mean difference between the two methods of −0.63 l·min−1 with an sd of 0.64 l·min−1. The lower and upper limits of agreement were −1.88 and 0.62 l·min−1, percentage limit of agreement was ±82.8%. Conclusions: The results show that EV is a safe, simple, noninvasive and cost‐effective method for continuous trend monitoring of CO in piglets. The agreement of the EV–CO with TPTD–CO is not good enough to replace the standard method in our animal model. A correction factor for body habitus in piglets may be beneficial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Cited by
Critchley, L. A., Lee, A., & Ho, A. M.-H. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181f08a5b · Cited by 512
Noori, S., Drabu, B., Soleymani, S., & Seri, I. (2012) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/fetalneonatal-2011-301090 · Cited by 146
Neonatal hemodynamics: Monitoring, data acquisition and analysis
Soleymani, S., Borzage, M., Noori, S., & Seri, I. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.32 · Cited by 23
Effect of hemodialysis on impedance cardiography (electrical velocimetry) parameters in children
Wilken, M., Oh, J., Pinnschmidt, H. O., Singer, D., & Blohm, M. E. (2020) · Pediatric Nephrology · doi:10.1007/s00467-019-04409-1 · Cited by 8
“Trend-following characteristics of EV have been assessed in very few studies [12, 16–19, 21–23] including studies on animal models [24, 25].”
MethodInfluential
Metadata
- Authors
- ALEXANDER OSTHAUS, W., HUBER, D., BECK, C., WINTERHALTER, M., BOETHIG, D., WESSEL, A., & SÜMPELMANN, R.
- Venue
- Pediatric Anesthesia
- Publisher
- Wiley
- Published
- 2007-06-26
- Volume
- 17
- Issue
- 8
- Pages
- 749-755
- ISSN
- 1155-5645 (ISSN-L)
- 1460-9592
- OpenAlex
- W2062179767
- Cited by
- 70
- References
- 3
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.