The Effect of Haematocrit on Reagent Strip Tests for Glucose

Wiener, K. · 1991 · Diabetic Medicine
Cited by 56

The DOI matches its Crossref record.

Abstract

Four blood glucose reagent strips (BM‐Test 1–44, Glucostix, Hypoguard GA, and Exactech), used in conjunction with measuring devices produced by the same manufacturer, were investigated with respect to the influence of haematocrit. The erythrocytes and plasma of fresh blood samples were separated, then remixed in different proportions to achieve a range of haematocrit values and the resulting specimens subjected to glucose assay. All the strip tests showed some influence of haematocrit, low haematocrits producing higher glucose results and vice versa, but some were much more affected than others. The Hypoguard GA was most affected and the BM‐Test 1–44 least. In the worst case, glucose results differed by 49% from one end of the normal adult haematocrit range to the other.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1464-5491.1991.tb01566.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 56

Metadata

Authors
Wiener, K.
Venue
Diabetic Medicine
Publisher
Wiley
Published
1991-02-03
Volume
8
Issue
2
Pages
172-175
ISSN
  • 0742-3071 (ISSN-L)
  • 1464-5491
OpenAlex
W2104270102
Cited by
56
References
0
FWCI
2.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Effect of Haematocrit on Reagent Strip Tests for Glucose. https://app.cochat.ai/papers/10.1111/j.1464-5491.1991.tb01566.x
The paper
Wiener, K. (1991). The Effect of Haematocrit on Reagent Strip Tests for Glucose. Diabetic Medicine. https://doi.org/10.1111/j.1464-5491.1991.tb01566.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.