Point-of-Care Glucose Testing

Louie, Richard F., Tang, Zuping, Sutton, Demetria V., Lee, Judith H., Kost, Gerald J. · 2000 · Archives of Pathology & Laboratory Medicine

Abstract

Objective.—To assess the clinical performance of glucose meter systems when used with critically ill patients. Design.—Two glucose meter systems (SureStepPro and Precision G) and a modular adaptation (Immediate Response Mobile Analysis-SureStepPro) were assessed clinically using arterial samples from critically ill patients. A biosensor-based analyzer (YSI 2700) and a hospital chemistry analyzer (Synchron CX-7) were the primary and secondary reference instruments, respectively. Patients and Setting.—Two hundred forty-seven critical care patients at the University of California, Davis, Medical Center participated in this study. Outcome Measures.—Error tolerances of ±15 mg/dL for glucose levels ≤100 mg/dL and ±15% for glucose levels >100 mg/dL were used to evaluate glucose meter performance; 95% of glucose meter measurements should fall within these tolerances. Results.—Compared to the primary reference method, 98% to 100% of SureStepPro and 91% to 95% of Precision G measurements fell within the error tolerances. Paired differences of glucose measurements versus critical care variables (Po2, pH, Pco2, and hematocrit) were analyzed to determine the effects of these variables on meter measurements. Po2 and Pco2 decreased Precision G and SureStepPro measurements, respectively, but not enough to be clinically significant based on the error tolerance criteria. Hematocrit levels affected glucose measurements on both meter systems. Modular adaptation did not affect test strip performance. Conclusions.—Glucose meter measurements correlated best with primary reference instrument measurements. Overall, both glucose meter systems showed acceptable performance for point-of-care testing. However, the effects of some critical care variables, especially low and high hematocrit values, could cause overestimated or underestimated glucose measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5858/2000-124-0257-pocgt

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 180

Metadata

Authors
Louie, R. F., Tang, Z., Sutton, D. V., Lee, J. H., & Kost, G. J.
Venue
Archives of Pathology & Laboratory Medicine
Published
2000-02-01
Volume
124
Issue
2
Pages
257-266
ISSN
  • 0003-9985 (ISSN-L)
  • 1543-2165
OpenAlex
W2138905008
Cited by
180
References
3
FWCI
4.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Point-of-Care Glucose Testing. https://app.cochat.ai/papers/10.5858/2000-124-0257-pocgt
The paper
Louie, R. F., Tang, Z., Sutton, D. V., Lee, J. H., & Kost, G. J. (2000). Point-of-Care Glucose Testing. Archives of Pathology & Laboratory Medicine. https://doi.org/10.5858/2000-124-0257-pocgt

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.