Reproducibility of the Short Insulin Tolerance Test
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The short insulin tolerance test is a simple method of estimating insulin resistance by measuring the rate of fall of blood glucose following the intravenous administration of insulin. To determine its reproducibility, 18 healthy subjects underwent duplicate insulin tolerance tests separated by at least 1 week. Intravenous insulin (0.05 units kg−1) was administered into an antecubital vein and arterialized venous samples were obtained from a retrogradely cannulated vein on the dorsum of the hand on the same side. The test was terminated with an intravenous glucose injection 15 min after the administration of insulin. The mean whole blood glucose concentration fell from 4.6 mmol l−1 to 2.8 mmol l−1 while plasma insulin concentrations rose to supraphysiological levels and declined exponentially. The glucose disappearance rate (Kitt) calculated from the slope of the fall in log transformed blood glucose between 3 and 15 min after insulin injection ranged from 2.1 to 6.5 (mean 4.4) % min−1 during the first visit and 1.7 to 7.4 (mean 4.4) % min−1 during the second. The ratio of the within‐subject to between‐subject variance of the test was 0.24, the within‐subject coefficient of variation was 13 % and the between‐subject coefficient of variation 26 %. The short insulin tolerance test is reproducible and could be used to measure insulin resistance in large‐scale epidemiological studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robinson, S., Chan, S., Spacey, S., Anyaoku, V., Johnston, D. G., & Franks, S. (1992) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1992.tb02262.x · Cited by 141
Cited by
WATER MEDIATION IN PROTEIN FOLDING AND MOLECULAR RECOGNITION
Levy, Y., & Onuchic, J. N. (2006) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.35.040405.102134 · Cited by 1,048
Thinness at birth and insulin resistance in adult life
Phillips, D. I. W., Barker, D. J. P., Hales, C. N., Hirst, S., & Osmond, C. (1994) · Diabetologia · doi:10.1007/s001250050086 · Cited by 697
Self-citationThe assessment of insulin resistance in man
Wallace, T. M., & Matthews, D. R. (2002) · Diabetic Medicine · doi:10.1046/j.1464-5491.2002.00745.x · Cited by 677
Phillips, D. I. W., Clark, P. M., Hales, C. N., & Osmond, C. (1994) · Diabetic Medicine · doi:10.1111/j.1464-5491.1994.tb00273.x · Cited by 631
Self-citationThörne, A., Lönnqvist, F., Apelman, J., Hellers, G., & Arner, P. (2002) · International Journal of Obesity · doi:10.1038/sj.ijo.0801871 · Cited by 463
Phillips, D. I. W., Caddy, S., Ilic, V., Fielding, B. A., Frayn, K. N., Borthwick, A. C., & Taylor, R. (1996) · Metabolism · doi:10.1016/s0026-0495(96)90260-7 · Cited by 390
Self-citationComparison of insulin sensitivity tests across a range of glucose tolerance from normal to diabetes
Hermans, M. P., Levy, J. C., Morris, R. J., & Turner, R. C. (1999) · Diabetologia · doi:10.1007/s001250051215 · Cited by 260
Evaluation of insulin sensitivity in clinical practice and in research settings
Monzillo, L. U., & Hamdy, O. (2003) · Nutrition Reviews · doi:10.1301/nr.2003.dec.397-412 · Cited by 259
Validation of HOMA-IR in a model of insulin-resistance induced by a high-fat diet in Wistar rats
Antunes, L. C., Elkfury, J. L., Jornada, M. N., Foletto, K. C., & Bertoluci, M. C. (2016) · Archives of Endocrinology and Metabolism · doi:10.1590/2359-3997000000169 · Cited by 247
Insulin sensitivity in women at risk of coronary heart disease and the effect of a low glycemic diet
Frost, G., Leeds, A., Trew, G., Margara, R., & Dornhorst, A. (1998) · Metabolism · doi:10.1016/s0026-0495(98)90331-6 · Cited by 243
Forouhi, N. G., Jenkinson, G., Thomas, E. L., Mullick, S., Mierisova, S., Bhonsle, U., McKeigue, P. M., & Bell, J. D. (1999) · Diabetologia · doi:10.1007/s001250051250 · Cited by 242
“Insulin sensitivity was measured by the short insulin tolerance test [8], during which the insulin sensitivity index (ISI, %/min) is”
MethodLam, J. C. M., Lam, B., Yao, T. J., Lai, A. Y. K., Ooi, C. G., Tam, S., Lam, K. S. L., & Ip, M. S. M. (2010) · European Respiratory Journal · doi:10.1183/09031936.00047709 · Cited by 170
Nam, J. H., Mun, J. I., Kim, S. I., Kang, S. W., Choi, K. H., Park, K., Ahn, C. W., Cha, B. S., Song, Y. D., Lim, S. K., et al. (2001) · Transplantation · doi:10.1097/00007890-200105270-00011 · Cited by 163
Trence, D. L., Kelly, J. L., & Hirsch, I. B. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030347 · Cited by 162
“The within-subject coefficient of variance (CV) for iv insulin is only 13%, whereas the between-subject CV is 26% (54).”
BackgroundMoberg, E., Kollind, M., Lins, P., & Adamson, U. (1995) · Diabetic Medicine · doi:10.1111/j.1464-5491.1995.tb00462.x · Cited by 40
Borghouts, L. (2021) · doi:10.26481/dis.20000211lb · Cited by 2
Metadata
- Authors
- Hirst, S., Phillips, D. I. W., Vines, S. K., Clark, P. M., & Hales, C. N.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 1993-11
- Volume
- 10
- Issue
- 9
- Pages
- 839-842
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W1966097054
- Cited by
- 65
- References
- 1
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.