CoChat

Stability of haemoglobin A1c (HbA1c) measurements from frozen whole blood samples stored for over a decade

Selvin, E., Coresh, J., Jordahl, J., Boland, L., Steffes, M. W. · 2005 · Diabetic Medicine
Cited by 57

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objective Haemoglobin A 1c (HbA 1c), a measure of long‐term glycaemic control, is at the centre of the clinical management of diabetes mellitus. However, the reproducibility of HbA 1c measurements from whole blood samples which have been in long‐term storage is unknown. We undertook this study to assess the reproducibility of HbA 1c measurements from whole blood samples that had been in storage at −70°C for over a decade. Research design and methods Three hundred and thirty‐six samples of frozen whole blood from the Atherosclerosis Risk in Communities (ARIC) Study, stored at −70°C for 11–14 years assayed for HbA 1c using a dedicated ion‐exchange HPLC assay (Tosoh A 1c 2.2 Plus HPLC) were compared with measurements on these same samples conducted prior to storage (in 1990–92) using a Diamat (Bio‐Rad) HPLC instrument. Results HbA 1c measurements from long‐term stored samples were strongly correlated with values obtained prior to long‐term storage (r = 0.97). The difference between HbA 1c from long‐ and short‐term stored samples had a mean of 0.35% HbA 1c (sd = 0.35) and a CV of 5.8%, which was approximately three times that of duplicate assays (CV 1.3 to 2.5%). Conclusions These data demonstrate that highly correlated but more variable and slightly higher HbA 1c results were obtained from frozen whole blood samples that have been in storage for more than a decade. This highly reproducible assay performance would lead to comparable ranking of individuals and unbiased estimates of relative risks and odds ratios in epidemiological studies (case‐control and cohort designs), but results should be realigned when the absolute value is of interest. These results have important implications for epidemiological studies and clinical trials which have stored whole blood specimens.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1464-5491.2005.01705.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 57

Metadata

Authors
Selvin, E., Coresh, J., Jordahl, J., Boland, L., & Steffes, M. W.
Venue
Diabetic Medicine
Publisher
Wiley
Published
2005-06-28
Volume
22
Issue
12
Pages
1726-1730
ISSN
  • 0742-3071 (ISSN-L)
  • 1464-5491
OpenAlex
W2063612255
Cited by
57
References
3
FWCI
1.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stability of haemoglobin A1c (HbA1c) measurements from frozen whole blood samples stored for over a decade. https://app.cochat.ai/papers/10.1111/j.1464-5491.2005.01705.x
The paper
Selvin, E., Coresh, J., Jordahl, J., Boland, L., & Steffes, M. W. (2005). Stability of haemoglobin A1c (HbA1c) measurements from frozen whole blood samples stored for over a decade. Diabetic Medicine. https://doi.org/10.1111/j.1464-5491.2005.01705.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.