Benefits of a bolus calculator in pre‐ and postprandial glycaemic control and meal flexibility of paediatric patients using continuous subcutaneous insulin infusion (CSII)
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Aims To assess the efficacy in pre‐ and postprandial glycaemic control and the impact on treatment satisfaction of a bolus calculator (Bolus Wizard) incorporated into the insulin pump in Type 1 diabetic (T1D) paediatric patients using continuous subcutaneous insulin infusion (CSII) treatment at various stages of pubertal development. Methods Thirty‐six T1D patients on CSII treatment (19 males; mean age 13.9 ± 3.5 years; range 4.9–17.8 years), were prospectively enrolled into this two‐period crossover study. Eighteen patients were randomized to begin phase A using the Bolus Wizard, followed by phase B, using their current conventional insulin dosing method to determine pre‐meal boluses. The remaining subjects were randomized to begin with phase B followed by phase A. Each study period lasted 2 weeks. A questionnaire assessing treatment satisfaction with the Bolus Wizard was compiled. Results There was a significant reduction in blood glucose levels before and 2 h after meals and in the number of correction boluses during phase A with respect to phase B of the study. The lower frequency of hypoglycaemic events during phase A did not reach statistical significance. There were no differences between the two phases: insulin requirement, daily bolus rate (%) and meal bolus quantity. Conclusions When paediatric patients used CSII, the bolus insulin dose calculated using the Bolus Wizard was more effective in improving pre‐ and postprandial glycaemic control with fewer correction boluses, without differences in the prandial insulin requirements and without restriction in the carbohydrate content of meals. The use of the Bolus Wizard was easy and was associated with a high level of satisfaction in these patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rabasa-Lhoret, R., Garon, J., Langelier, H., Poisson, D., & Chiasson, J. L. (1999) · Diabetes Care · doi:10.2337/diacare.22.5.667 · Cited by 210
Cited by
Insulin-pump therapy for type 1 diabetes mellitus
Pickup, J. C. (2012) · New England Journal of Medicine · doi:10.1056/nejmct1113948 · Cited by 270
Evolution of Insulin Delivery Devices: From Syringes, Pens, and Pumps to DIY Artificial Pancreas
Kesavadev, J., Saboo, B., Krishna, M. B., & Krishnan, G. (2020) · Diabetes Therapy · doi:10.1007/s13300-020-00831-z · Cited by 221
Schmidt, S., & Nørgaard, K. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814532906 · Cited by 170
Improved A1C Levels in Type 1 Diabetes with Smartphone App Use
Ryan, E. A., Holland, J., Stroulia, E., Bazelli, B., Babwik, S. A., Li, H., Senior, P., & Greiner, R. (2017) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2016.06.001 · Cited by 63
“Shasaj (21) showed that a bolus calculator used by the pediatric population lowered the pre- and post-meal glucose levels but not the A1C levels.”
BackgroundChoudhary, P., & Amiel, S. A. (2018) · Diabetologia · doi:10.1007/s00125-018-4566-6 · Cited by 52
Metadata
- Authors
- Shashaj, B., Busetto, E., & Sulli, N.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2008-08-29
- Volume
- 25
- Issue
- 9
- Pages
- 1036-1042
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W1983849099
- Cited by
- 96
- References
- 1
- FWCI
- 2.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Benefits of a bolus calculator in pre‐ and postprandial glycaemic control and meal flexibility of paediatric patients using continuous subcutaneous insulin infusion (CSII). https://app.cochat.ai/papers/10.1111/j.1464-5491.2008.02549.x
- The paper
- Shashaj, B., Busetto, E., & Sulli, N. (2008). Benefits of a bolus calculator in pre‐ and postprandial glycaemic control and meal flexibility of paediatric patients using continuous subcutaneous insulin infusion (CSII). Diabetic Medicine. https://doi.org/10.1111/j.1464-5491.2008.02549.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.