The DOI matches its Crossref record; 53 of the 56 references it cites were found in a registry or an index.
Point-of-care tests for diagnosing infections in the developing world
Open accessAbstract
Infectious diseases continue to cause an enormous burden of death and disability in developing countries. Increasing access to appropriate treatment for infectious diseases could have a major impact on disease burden. Some common infections can be managed syndromically without the need for diagnostic tests, but this is not appropriate for many infectious diseases, in which a positive diagnostic test is needed before treatment can be given. Since many people in developing countries do not have access to laboratory services, diagnosis depends on the availability of point of care (POC) tests. Historically there has been little investment in POC tests for diseases that are common in developing countries, but that is now changing. Lack of regulation of diagnostic tests in many countries has resulted in the widespread use of sub-standard POC tests, especially for malaria, making it difficult for manufacturers of reliable POC tests to compete. In recent years increased investment, technological advances, and greater awareness about the importance of reliable diagnostic tests has resulted in rapid progress. Rapid, reliable and affordable POC tests, requiring no equipment and minimal training, are now available for HIV infection, syphilis and malaria, but POC tests for other infections are urgently needed. Many countries do not have established criteria for licensing and introducing new diagnostic tests, and many clinicians in developing countries have become disillusioned with diagnostic tests and prefer to rely on clinical judgment. Continuing advocacy and training in the use of POC tests are needed, and systems for quality control of POC tests need to be developed if they are to achieve their maximum potential.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Distance to care, lack of connectivity, and poor laboratory infrastructure in many resource-poor areas precludes the widespread adoption of resource-heavy diagnostic techniques, such as skin biopsy reads by dermatopathologists”
From Global Burden of Skin Disease: Inequities and Innovations (2017) · cites this paper as [42]
Citations
Cites
DNA Detection Using Recombination Proteins
Piepenburg, O., Williams, C. H., Stemple, D. L., & Armes, N. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040204 · Cited by 2,503
WHO estimates of the causes of death in children
Bryce, J., Boschi-Pinto, C., Shibuya, K., & Black, R. E. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71877-8 · Cited by 2,108
World Development Report 2004 : making services work for poor people
Pritchett, L. H., Gauthier, B., Devarajan, S., Filmer, D. P., Commins, S. K., Hammer, J. S., Shah, S., Soucat, A. L. B., & Aḥmad, J. (2003) · Cited by 1,517
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Diagnostics for the developing world
Mabey, D., Peeling, R. W., Ustianowski, A., & Perkins, M. D. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro841 · Cited by 1,054
Self-citationBacteremia among Children Admitted to a Rural Hospital in Kenya
Berkley, J. A., Lowe, B. S., Mwangi, I., Williams, T., Bauni, E., Mwarumba, S., Ngetsa, C., Slack, M. P. E., Njenga, S., Hart, C. A., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa040275 · Cited by 851
Laboratory medicine in Africa: a barrier to effective health care
Petti, C. A., Polage, C. R., Quinn, T. C., Ronald, A. R., & Sande, M. A. (2006) · Clinical Infectious Diseases · doi:10.1086/499363 · Cited by 749
Overdiagnosis of malaria in patients with severe febrile illness in Tanzania: a prospective study
Reyburn, H., Mbatia, R., DRAKELEY, C. J., Carneiro, I. A., Mwakasungula, E., Mwerinde, O., Saganda, K., Shao, J. F., Kitua, A. Y., Olomi, R. M., et al. (2004) · BMJ · doi:10.1136/bmj.38251.658229.55 · Cited by 675
Rapid tests for sexually transmitted infections (STIs): the way forward
Peeling, R. W. W., Holmes, K. K., Mabey, D. C. W., & Ronald, A. (2006) · Sexually Transmitted Infections · doi:10.1136/sti.2006.024265 · Cited by 601
Self-citationRequirements for high impact diagnostics in the developing world
Urdea, M. S., Penny, L., Olmsted, S. S., Giovanni, M. Y., Kaspar, P., Shepherd, A., Wilson, P. L., Dahl, C. A., Buchsbaum, S., Moeller, G., et al. (2006) · Nature · doi:10.1038/nature05448 · Cited by 589
Cited by
Sorted by citations
Items 101–200 of 497
Vaca, D. J., Dobler, G., Fischer, S. F., Keller, C. A., Konrad, M., von Loewenich, F. D., Orenga, S., Sapre, S. U., van Belkum, A., & Kempf, V. A. J. (2022) · FEMS Microbiology Reviews · doi:10.1093/femsre/fuac013 · Cited by 50
Continuous-flow, microfluidic, qRT-PCR system for RNA virus detection
Fernández-Carballo, B. L., McBeth, C., McGuiness, I., Kalashnikov, M., Baum, C., Borrós, S., Sharon, A., & Sauer-Budge, A. F. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-017-0689-8 · Cited by 49
Advances in Directly Amplifying Nucleic Acids from Complex Samples
Walker, F. M., & Hsieh, K. (2019) · Biosensors · doi:10.3390/bios9040117 · Cited by 51
Yotsu, R. R., Fuller, L. C., Murdoch, M. E., van Brakel, W. H., Revankar, C. R., Barogui, M. Y. T., Ruiz-Postigo, J. A., Dagne, D. A., Asiedu, K. B., & Hay, R. J. (2023) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0011357 · Cited by 50
Haney, K. E., Tandon, P., Divi, R. L., Ossandon, M. R., Baker, H., & Pearlman, P. C. (2017) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2017.2761764 · Cited by 48
Semiquantitative Nucleic Acid Test with Simultaneous Isotachophoretic Extraction and Amplification
Bender, A. T., Borysiak, M. D., Levenson, A. M., Lillis, L. L., Boyle, D. S., & Posner, J. D. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00185 · Cited by 48
Toward Paper-Based Sensors: Turning Electrical Signals into an Optical Readout System
Liana, D. D., Raguse, B., Gooding, J. J., & Chow, E. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b04941 · Cited by 47
Improving access to new diagnostics through harmonised regulation: priorities for action
McNerney, R., Sollis, K. A., & Peeling, R. W. W. (2014) · African Journal of Laboratory Medicine · doi:10.4102/ajlm.v3i1.123 · Cited by 46
Self-citationElectrochemical Paper‐Based Microfluidics: Harnessing Capillary Flow for Advanced Diagnostics
Bezinge, L., Shih, C., Richards, D. A., & deMello, A. J. (2024) · Small · doi:10.1002/smll.202401148 · Cited by 46
Anderson, D. A., Crowe, S. M., & Garcia, M. L. (2010) · Current HIV/AIDS Reports · doi:10.1007/s11904-010-0067-z · Cited by 46
Ferguson, W., Kemp, K. K., & Kost, G. J. (2016) · International Journal of Health Geographics · doi:10.1186/s12942-016-0037-9 · Cited by 46
Novel versatile smart phone based Microplate readers for on-site diagnoses
Fu, Q., Wu, Z., Li, X., Yao, C., Yu, S., Xiao, W., & Tang, Y. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.03.049 · Cited by 46
Development of a rapid antibody test for point-of-care diagnosis of animal African trypanosomosis
Boulangé, A. F., Pillay, D., Chevtzoff, C., Biteau, N., de Graça, V. C., Rempeters, L., Theodoridis, D., & Baltz, T. (2016) · Veterinary Parasitology · doi:10.1016/j.vetpar.2016.11.017 · Cited by 46
Lin, C.-T., Kuo, S.-H., Lin, P.-H., Chiang, P.-H., Lin, W.-H., Chang, C.-H., Tsou, P., & Li, B. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128003 · Cited by 45
Wadhwa, A., Hickling, G. J., & Eda, S. (2012) · Veterinary Medicine International · doi:10.1155/2012/674238 · Cited by 44
Rasti, R., Nanjebe, D., Karlström, J., Muchunguzi, C., Mwanga‐Amumpaire, J., Gantelius, J., Mårtensson, A., Rivas, L., Galban, F., Reuterswärd, P., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0182005 · Cited by 43
Ciftci, S., Cánovas, R., Neumann, F., Paulraj, T., Nilsson, M. F., Crespo, G. A., & Madaboosi, N. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.112002 · Cited by 43
Erber, A. C., Sandler, P. J., de Avelar, D. M., Swoboda, I., Cota, G., & Walochnik, J. (2022) · Parasites & Vectors · doi:10.1186/s13071-021-05133-2 · Cited by 46
State of diagnosing infectious pathogens using colloidal nanomaterials
Kim, J., Mohamed, M. A. A., Zagorovsky, K., & Chan, W. C. W. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.08.013 · Cited by 44
Ultrarobust Biochips with Metal–Organic Framework Coating for Point-of-Care Diagnosis
Wang, C., Wang, L., Tadepalli, S., Morrissey, J. J., Kharasch, E. D., Naik, R. R., & Singamaneni, S. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00762 · Cited by 42
Evaluation of the Diagnostic Accuracy of Prototype Rapid Tests for Human African Trypanosomiasis
Sternberg, J. M., Gierliński, M., Biéler, S., Ferguson, M. A. J., & Ndung’u, J. M. (2014) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0003373 · Cited by 41
Gilmore, J., Islam, M., & Martínez‐Duarte, R. (2016) · Micromachines · doi:10.3390/mi7040052 · Cited by 41
White blood cell counting at point‐of‐care testing: A review
Luo, J., Chen, C., & Li, Q. (2020) · Electrophoresis · doi:10.1002/elps.202000029 · Cited by 41
Sadiq, S. T., Mazzaferri, F., & Unemo, M. (2017) · Sexually Transmitted Infections · doi:10.1136/sextrans-2016-053072 · Cited by 40
Radolf, J. D., Tramont, E. C., & Salazar, J. C. (2015) · Elsevier eBooks · doi:10.1016/b978-1-4557-4801-3.00239-3 · Cited by 40
Young, N., Taegtmeyer, M., Aol, G., Bigogo, G., Phillips‐Howard, P. A., Hill, J., Laserson, K. F., ter Kuile, F. O., & Desai, M. R. (2018) · PLoS ONE · doi:10.1371/journal.pone.0198784 · Cited by 41
Rees, C. A., Lim, J. K., Westbrook, A. L., Helou, R. E., Schmid, A. M., Rubin-Smith, J. E., Shreeve, K. M., Rotman, C., Govindapillai, S., Dorney, K., et al. (2023) · BMJ Paediatrics Open · doi:10.1136/bmjpo-2022-001627 · Cited by 41
Rapid and sensitive colorimetric detection of pathogens based on silver–urease interactions
Singh, P., Kakkar, S., Bharti, B., Kumar, R., & Bhalla, V. (2019) · Chemical Communications · doi:10.1039/c9cc00225a · Cited by 39
The Value of Clinical Needs Assessments for Point-of-Care Diagnostics
Weigl, B. H., Gaydos, C. A., Kost, G. J., Beyette, F. R., Sabourin, S., Rompalo, A. M., Santos, T. D. L., McMullan, J. T., & Haller, J. (2012) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/poc.0b013e31825a241e · Cited by 39
Point-of-care tests for sexually transmissible infections: what do ‘end users’ want?
Rompalo, A. M., Hsieh, Y., Hogan, T., Barnes, M., Jett‐Goheen, M., Huppert, J. S., & Gaydos, C. A. (2013) · Sexual Health · doi:10.1071/sh13047 · Cited by 39
Rapid Analytical Methods for On-Site Triage for Traumatic Brain Injury
North, S. H., Shriver‐Lake, L. C., Taitt, C. R., & Ligler, F. S. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143105 · Cited by 40
Madimenos, F. C., Gildner, T. E., Eick, G. N., Sugiyama, L. S., & Snodgrass, J. J. (2022) · American Journal of Human Biology · doi:10.1002/ajhb.23808 · Cited by 37
Trends in ready-to-use portable electrochemical sensing devices for healthcare diagnosis
Sajeevan, A., Sukumaran, R. A., Panicker, L. R., & Goud, K. Y. (2025) · Microchimica Acta · doi:10.1007/s00604-024-06916-x · Cited by 39
Peeling, R. W. W. (2015) · International Health · doi:10.1093/inthealth/ihv062 · Cited by 36
Self-citationA laminar-flow based microbial fuel cell array
Yang, W., Lee, K. K., & Choi, S. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.11.155 · Cited by 36
Wei, M., Li, X., & Serpe, M. J. (2019) · ACS Applied Polymer Materials · doi:10.1021/acsapm.8b00207 · Cited by 36
Freiman, J. M., Wang, J., Easterbrook, P., Horsburgh, C. R., Marinucci, F., White, L. F., Kamkamidze, G., Krajden, M., Loarec, A., Njouom, R., et al. (2019) · Journal of Hepatology · doi:10.1016/j.jhep.2019.02.011 · Cited by 36
The use of Nanotrap particles for biodefense and emerging infectious disease diagnostics
Shafagati, N., Patanarut, A., Luchini, A., Lundberg, L., Bailey, C., Petricoin, E. F., Liotta, L. A., Narayanan, A., Lepene, B. S., & Kehn‐Hall, K. (2014) · Pathogens and Disease · doi:10.1111/2049-632x.12136 · Cited by 36
Nanofluidics in point of care applications
Segerink, L. I., & Eijkel, J. C. T. (2014) · Lab on a Chip · doi:10.1039/c4lc00298a · Cited by 39
Rylance, J., Gordon, S. B., Naeher, L. P., Patel, A., Balmes, J. R., Adetona, O., Rogalsky, D. K., & Martin, W. J. (2013) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00416.2012 · Cited by 35
Gosselin, D., Gougis, M., Baque, M., Navarro, F. P., Belgacem, M. N., Chaussy, D., Bourdat, A.-G., Mailley, P., & Berthier, J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02394 · Cited by 35
Evaluation of PIMA™® Point of Care Technology for CD4 T Cell Enumeration in Kenya
Mwau, M., Adungo, F., Kadima, S., Njagi, E., Kirwaye, C., Abubakr, N. S., Okubi, L., Waihenya, M., Lusike, J., & Hungu, J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0067612 · Cited by 34
Park, Y. M., Lim, S., Shin, S. J., Kim, C. H., Jeong, S. W., Shin, S. Y., Bae, N. H., Lee, S. J., Na, J., Jung, G. Y., et al. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.03.061 · Cited by 34
Ryu, J. H., Kwon, M., Moon, J.-D., Hwang, M.-W., Lee, J.-M., Park, K., Yun, S. J., Bae, H. J., Choi, A., Lee, H., et al. (2018) · Annals of Laboratory Medicine · doi:10.3343/alm.2018.38.6.578 · Cited by 34
Developments in the Diagnostic Techniques of Infectious Diseases: Rural and Urban Prospective
Srivastava, S., Singh, P. K., Vatsalya, V., & Karch, R. C. (2018) · Advances in Infectious Diseases · doi:10.4236/aid.2018.83012 · Cited by 34
The introduction of syphilis point of care tests in resource limited settings
Marks, M., & Mabey, D. C. W. (2017) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2017.1303379 · Cited by 34
Self-citationDNA Methylation-Based Point-of-Care Cancer Detection: Challenges and Possibilities
Sina, A. A. I., Carrascosa, L. G., & Trau, M. (2019) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2019.05.014 · Cited by 33
Efficient Error Recovery in Cyberphysical Digital-Microfluidic Biochips
Ibrahim, M., & Chakrabarty, K. (2015) · IEEE Transactions on Multi-Scale Computing Systems · doi:10.1109/tmscs.2015.2478457 · Cited by 32
Multiplex Nucleic Acid Amplification Test for Diagnosis of Dengue Fever, Malaria, and Leptospirosis
Waggoner, J. J., Abeynayake, J. I., Balassiano, I. T., Lefterova, M. I., Sahoo, M. K., Liu, Y., Vital-Brazil, J. M., Gresh, L., Balmaseda, Á., Harris, E., et al. (2014) · Journal of Clinical Microbiology · doi:10.1128/jcm.00341-14 · Cited by 32
Lam, M., Gadzikwa, T. L., Nguyen, T., Kausar, A., Alladin‐Mustan, B. S., Sikder, M. D. H., & Gibbs, J. M. (2015) · Langmuir · doi:10.1021/acs.langmuir.5b03777 · Cited by 32
Gómez, C. A., Budvytyte, L., Press, C., Zhou, L., McLeod, R. L., Maldonado, Y., Montoya, J. G., & Contopoulos‐Ioannidis, D. G. (2018) · Open Forum Infectious Diseases · doi:10.1093/ofid/ofy215 · Cited by 32
Point-of-Care Testing in Microbiology: A Mechanism for Improving Patient Outcomes
Hansen, G. T. (2019) · Clinical Chemistry · doi:10.1373/clinchem.2019.304782 · Cited by 32
Evaluation of a new point-of-care oral anti-HCV test for screening of hepatitis C virus infection
Liu, L., Zhang, M., Hang, L., Kong, F., Yan, H., Zhang, Y., Feng, X., Gao, Y., Wang, C., Ma, H., et al. (2020) · Virology Journal · doi:10.1186/s12985-020-1293-7 · Cited by 32
Nicholson, A. M., Tennant, I. A., White, L. A., Thoms-Rodriguez, C.-A., Cook, L. D., Johnson, S., Thompson, T. K., Barnett, J., & Richards, L. R. (2018) · Antimicrobial Resistance and Infection Control · doi:10.1186/s13756-018-0315-3 · Cited by 35
Röltgen, K., & Pluschke, G. (2019) · Springer eBooks · doi:10.1007/978-3-030-11114-4 · Cited by 32
Buzdugan, S. N., Vergne, T., Grosbois, V., Delahay, R. J., & Drewe, J. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-00806-4 · Cited by 31
Park, Y. M., Kim, C. H., Lee, S. J., & Lee, M. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111415 · Cited by 31
Paper-based chemiresistor for detection of ultralow concentrations of protein
Pozuelo, M., Blondeau, P., Novell, M., Andrade, F. J., Rius, F. X., & Riu, J. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.06.007 · Cited by 31
A glass fiber sheet-based electroosmotic lateral flow immunoassay for point-of-care testing
Oyama, Y., Osaki, T., Kamiya, K., Kawano, R., Honjoh, T., Shibata, H., Ide, T., & Takeuchi, S. (2012) · Lab on a Chip · doi:10.1039/c2lc40994a · Cited by 31
Value of routine dengue diagnosis in endemic countries
Ayukekbong, J. A., Oyero, O. G., Nnukwu, S. E., Mesumbe, H. N., & Fobisong, C. (2017) · World Journal of Virology · doi:10.5501/wjv.v6.i1.9 · Cited by 31
Gomez, E. G., Igunza, K. A., Madewell, Z. J., Akelo, V., Onyango, D., Arifeen, S. E., Gurley, E. S., Hossain, M. Z., Chowdhury, M. A. I., Islam, K. M., et al. (2024) · PLOS Global Public Health · doi:10.1371/journal.pgph.0002494 · Cited by 30
Diagnostic tools for tackling febrile illness and enhancing patient management
Mitsakakis, K., D’Acremont, V., Hin, S., von Stetten, F., & Zengerle, R. (2018) · Microelectronic Engineering · doi:10.1016/j.mee.2018.10.001 · Cited by 32
Ghodake, G. S., Shinde, S. K., Kadam, A. A., Saratale, R. G., Saratale, G. D., Syed, A., Elgorban, A. M., Marraiki, N., & Kim, D.-Y. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.112969 · Cited by 31
Kumar, S., Sharma, S., Bhardwaj, N., Pande, V., Savargaonkar, D., & Anvikar, A. R. (2021) · Journal of Virological Methods · doi:10.1016/j.jviromet.2021.114168 · Cited by 29
Evaluating Operational Specifications of Point-of-Care Diagnostic Tests: A Standardized Scorecard
Lehe, J. D., Sitoe, N. E., Tobaiwa, O., Loquiha, O., Quevedo, J. I., PETER, T. F., & Jani, I. V. (2012) · PLoS ONE · doi:10.1371/journal.pone.0047459 · Cited by 29
Zhu, A. Y., & Cubukcu, E. (2015) · 2D Materials · doi:10.1088/2053-1583/2/3/032005 · Cited by 30
Aborode, A. T., Adesola, R. O., Scott, G. Y., Hayford, E. A., Otorkpa, O. J., Kwaku, S. D., Elebesunu, E. E., Nibokun, E. O., Aruorivwooghene, I. J., Bakre, A. A., et al. (2025) · Advances in Biomarker Sciences and Technology · doi:10.1016/j.abst.2025.01.001 · Cited by 28
Kubota, R., LaBarre, P., Singleton, J., Beddoe, A., & Weigl, B. H. (2011) · Biological Engineering Transactions · doi:10.13031/2013.38508 · Cited by 28
HIV-1 Tat biosensor: Current development and trends for early detection strategies
Fatin, M. F., Ruslinda, A. R., Arshad, M. K. M., Tee, K. K., Ayub, R. M., Hashim, U., Kamarulzaman, A., & Gopinath, S. C. B. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.067 · Cited by 28
Baiden, F., Malm, K., Bart-Plange, C., Hodgson, A., Chandramohan, D., Webster, J., & Owusu‐Agyei, S. (2014) · Ghana Medical Journal · doi:10.4314/gmj.v48i2.10 · Cited by 27
Ultrastable Plasmonic Bioink for Printable Point-Of-Care Biosensors
Yin, Z., Guo, H., Li, Y., Chiu, J., & Tian, L. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c11799 · Cited by 27
Maluleke, K., Musekiwa, A., Kgarosi, K., Gregor, E. M., Dlangalala, T., Nkambule, S. J., & Mashamba-Thompson, T. P. (2021) · Diagnostics · doi:10.3390/diagnostics11122299 · Cited by 27
Punjabi, K., Adhikary, R. R., Patnaik, A., Bendale, P., Saxena, S., & Banerjee, R. (2022) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.2c00299 · Cited by 27
Aqueous two-phase systems as multipurpose tools to improve biomarker analysis
Mendes, M. S. M., Rosa, M. E., Ramalho, F., Freire, M. G., & Silva, F. A. E. (2023) · Separation and Purification Technology · doi:10.1016/j.seppur.2023.123875 · Cited by 30
Rhedin, S., Eklundh, A., Rinder, M. R., Peltola, V. T., Waris, M. E., Gantelius, J., Lindh, M., Andersson, M., Gaudenzi, G., Mårtensson, A., et al. (2022) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2022.05.008 · Cited by 26
Hutchinson, E., Reyburn, H., Hamlyn, E., Long, K., Meta, J., Mbakilwa, H., & Chandler, C. (2015) · Global Public Health · doi:10.1080/17441692.2015.1091025 · Cited by 26
Sensing parasites: Proteomic and advanced bio-detection alternatives
Sánchez-Ovejero, C., Benito‐Lopez, F., Díez, P., Casulli, A., Siles‐Lucas, M., Fuentes, M., & Manzano-Román, R. (2016) · Journal of Proteomics · doi:10.1016/j.jprot.2015.12.030 · Cited by 26
Stevens, W. S., Gous, N. M., MacLeod, W., Long, L. C., Variava, E., Martinson, N. A., Sanne, I., Osih, R. B., & Scott, L. E. (2017) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0000000000001456 · Cited by 26
Yu, C. Y., Ang, G. Y., Chan, K., Singh, K. K. B., & Yean, C. Y. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.048 · Cited by 25
Drugs and Diagnostic Innovations to Improve Global Health
Peeling, R. W. W., & Nwaka, S. (2011) · Infectious Disease Clinics of North America · doi:10.1016/j.idc.2011.06.002 · Cited by 24
Self-citationKosack, C., & Nick, S. (2016) · Tropical Medicine & International Health · doi:10.1111/tmi.12688 · Cited by 24
Valuing Simplicity: Developing a Good Point of Care Diagnostic
Engel, N., & Krumeich, A. J. S. M. (2020) · Frontiers in Sociology · doi:10.3389/fsoc.2020.00037 · Cited by 24
Mitra, P., & Sharma, P. (2021) · PubMed Central · Cited by 24
Laboratory Diagnosis of Buruli Ulcer: Challenges and Future Perspectives
Röltgen, K., Cruz, I., Ndung’u, J. M., & Pluschke, G. (2019) · Springer eBooks · doi:10.1007/978-3-030-11114-4_10 · Cited by 24
Li, R., Chen, J., Zhang, X., Cui, J., Tao, S., & Yang, L. (2019) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.9b06979 · Cited by 24
Electrical Chips for Biological Point-of-Care Detection
Reddy, B., Salm, E. M., & Bashir, R. (2016) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104643 · Cited by 27
Saweri, O. P., Batura, N., Adawiyah, R. A., Causer, L. M., Pomat, W. S., Vallely, A. J., & Wiseman, V. L. (2021) · PLoS ONE · doi:10.1371/journal.pone.0253135 · Cited by 23
Self-powered switch-controlled nucleic acid extraction system
Han, K., Yoon, Y.-J., Shin, Y. M., & Park, M. K. (2015) · Lab on a Chip · doi:10.1039/c5lc00891c · Cited by 23
Bauer, M., & Kulinsky, L. (2018) · Micromachines · doi:10.3390/mi9010027 · Cited by 23
Mubanga, C. M., Mwape, K. E., Phiri, I. K., Trevisan, C., Zulu, G., Chabala, C., Damme, I. V., Schmidt, V., Dorny, P., & Gabriël, S. (2019) · Acta Tropica · doi:10.1016/j.actatropica.2019.03.030 · Cited by 23
Upaassana, V. T., Ghosh, S., Chakraborty, A., Birch, M. E., Joseph, P., Han, J., Ku, B. K., & Ahn, C. H. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00582 · Cited by 23
State of the art syphilis diagnostics: rapid point-of-care tests
Kay, N., Peeling, R. W. W., & Mabey, D. C. W. (2013) · Expert Review of Anti-infective Therapy · doi:10.1586/14787210.2014.860356 · Cited by 22
Self-citationOriero, E. C., Geertruyden, J. V., Nwakanma, D. C., D’Alessandro, U., & Jacobs, J. A. (2015) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2015.1090878 · Cited by 22
Osório, L., Luna, J. A. G., Parra‐Lara, L. G., Garcia, V., Torres, L., Degroote, S., & Ridde, V. (2018) · Infectious Diseases of Poverty · doi:10.1186/s40249-018-0474-8 · Cited by 24
Paquin, P., Durmort, C., Paulus, C., Vernet, T., Marcoux, P. R., & Morales, S. (2022) · PLOS Digital Health · doi:10.1371/journal.pdig.0000122 · Cited by 22
Meulah, B., Bengtson, M., van Lieshout, L., Hokke, C. H., Kreidenweiss, A., Diehl, J. C., Adégnika, A. A., & Agbana, T. (2022) · Parasitology · doi:10.1017/s0031182022001664 · Cited by 22
Galli, R. A., Green, K. F., Marca, A. L., Waldman, L. F., Powers, R. E., Daly, A. C., & Shackleton, C. R. (2013) · Journal of Clinical Virology · doi:10.1016/j.jcv.2013.08.024 · Cited by 21
Implementation and Operational Research
Gous, N. M., Scott, L. E., Potgieter, J., Ntabeni, L., Sanne, I., & Stevens, W. S. (2015) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0000000000000872 · Cited by 20
Chakma, B., Jain, P., Singh, N. K., & Goswami, P. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03315 · Cited by 20
Schary, W., Paskali, F., Rentschler, S., Ruppert, C., Wagner, G. E., Steinmetz, I., Deigner, H., & Kohl, M. (2022) · Diagnostics · doi:10.3390/diagnostics12030589 · Cited by 22
Metadata
- Authors
- Peeling, R. W., & Mabey, D.
- Affiliations
- London School of Hygiene & Tropical Medicine (GB)
- Corresponding author
- Peeling, R.W.
- Venue
- Clinical Microbiology and Infection
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 16
- Issue
- 8
- Pages
- 1062-1069
- ISSN
- 1198-743X (ISSN-L)
- OpenAlex
- W1748737970
- Cited by
- 500
- References
- 56
- Citations by year
- 2026: 31 · 2025: 19 · 2024: 30 · 2023: 20 · 2022: 23 · 2021: 27 · 2020: 45 · 2019: 37 · 2018: 47 · 2017: 36 · 2016: 44 · 2015: 45 · 2014: 29 · 2013: 32 · 2012: 18
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Clinical Microbiology and Infection (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Wellcome Trust
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Keywords
- point-of-care testing, infectious disease diagnosis, developing countries, malaria diagnosis, HIV testing, syphilis testing, diagnostic test regulation, syndromic management
- MeSH terms
- Developing Countries, Education, Medical, Continuing, Humans, Malaria, Quality Control, Syphilis, HIV Infections, Point-of-Care Systems, Molecular Diagnostic Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review