The DOI matches its Crossref record; 53 of the 56 references it cites were found in a registry or an index.
Point-of-care tests for diagnosing infections in the developing world
Open accessAbstract
Infectious diseases continue to cause an enormous burden of death and disability in developing countries. Increasing access to appropriate treatment for infectious diseases could have a major impact on disease burden. Some common infections can be managed syndromically without the need for diagnostic tests, but this is not appropriate for many infectious diseases, in which a positive diagnostic test is needed before treatment can be given. Since many people in developing countries do not have access to laboratory services, diagnosis depends on the availability of point of care (POC) tests. Historically there has been little investment in POC tests for diseases that are common in developing countries, but that is now changing. Lack of regulation of diagnostic tests in many countries has resulted in the widespread use of sub-standard POC tests, especially for malaria, making it difficult for manufacturers of reliable POC tests to compete. In recent years increased investment, technological advances, and greater awareness about the importance of reliable diagnostic tests has resulted in rapid progress. Rapid, reliable and affordable POC tests, requiring no equipment and minimal training, are now available for HIV infection, syphilis and malaria, but POC tests for other infections are urgently needed. Many countries do not have established criteria for licensing and introducing new diagnostic tests, and many clinicians in developing countries have become disillusioned with diagnostic tests and prefer to rely on clinical judgment. Continuing advocacy and training in the use of POC tests are needed, and systems for quality control of POC tests need to be developed if they are to achieve their maximum potential.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Distance to care, lack of connectivity, and poor laboratory infrastructure in many resource-poor areas precludes the widespread adoption of resource-heavy diagnostic techniques, such as skin biopsy reads by dermatopathologists”
From Global Burden of Skin Disease: Inequities and Innovations (2017) · cites this paper as [42]
Citations
Cites
DNA Detection Using Recombination Proteins
Piepenburg, O., Williams, C. H., Stemple, D. L., & Armes, N. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040204 · Cited by 2,503
WHO estimates of the causes of death in children
Bryce, J., Boschi-Pinto, C., Shibuya, K., & Black, R. E. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71877-8 · Cited by 2,108
World Development Report 2004 : making services work for poor people
Pritchett, L. H., Gauthier, B., Devarajan, S., Filmer, D. P., Commins, S. K., Hammer, J. S., Shah, S., Soucat, A. L. B., & Aḥmad, J. (2003) · Cited by 1,517
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Diagnostics for the developing world
Mabey, D., Peeling, R. W., Ustianowski, A., & Perkins, M. D. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro841 · Cited by 1,054
Self-citationBacteremia among Children Admitted to a Rural Hospital in Kenya
Berkley, J. A., Lowe, B. S., Mwangi, I., Williams, T., Bauni, E., Mwarumba, S., Ngetsa, C., Slack, M. P. E., Njenga, S., Hart, C. A., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa040275 · Cited by 851
Laboratory medicine in Africa: a barrier to effective health care
Petti, C. A., Polage, C. R., Quinn, T. C., Ronald, A. R., & Sande, M. A. (2006) · Clinical Infectious Diseases · doi:10.1086/499363 · Cited by 749
Overdiagnosis of malaria in patients with severe febrile illness in Tanzania: a prospective study
Reyburn, H., Mbatia, R., DRAKELEY, C. J., Carneiro, I. A., Mwakasungula, E., Mwerinde, O., Saganda, K., Shao, J. F., Kitua, A. Y., Olomi, R. M., et al. (2004) · BMJ · doi:10.1136/bmj.38251.658229.55 · Cited by 675
Rapid tests for sexually transmitted infections (STIs): the way forward
Peeling, R. W. W., Holmes, K. K., Mabey, D. C. W., & Ronald, A. (2006) · Sexually Transmitted Infections · doi:10.1136/sti.2006.024265 · Cited by 601
Self-citationRequirements for high impact diagnostics in the developing world
Urdea, M. S., Penny, L., Olmsted, S. S., Giovanni, M. Y., Kaspar, P., Shepherd, A., Wilson, P. L., Dahl, C. A., Buchsbaum, S., Moeller, G., et al. (2006) · Nature · doi:10.1038/nature05448 · Cited by 589
Cited by
Sorted by citations
Items 401–497 of 497
Rapid Point-of-Care Diagnosis of Malaria and Dengue Infection
(2016) · Molecular Microbiology · doi:10.1128/9781555819071.ch42 · Cited by 1
Raqeema, S., Hashim, U., & Parmin, N. A. (2016) · AIP conference proceedings · doi:10.1063/1.4948899 · Cited by 1
Chemiplasmonics for high-throughput biosensors
Raghavendra, A. J., Zhu, J., Gregory, W. E., Case, F., Mulpur, P., Khan, S. A., Srivastava, A., & Podila, R. (2018) · International Journal of Nanomedicine · doi:10.2147/ijn.s186644 · Cited by 1
Paper-based isothermal DNA amplification and real-time analysis
Liu, M., Monshat, H., Zhao, Y., & Lu, M. (2019) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors43011.2019.8956819 · Cited by 1
Fernandes, F. (2020) · Biomedical Journal of Scientific & Technical Research · doi:10.26717/bjstr.2020.32.005182 · Cited by 1
Biosensors for Early Disease Diagnosis
Topal, A. E., Özkan, A. D., Dâna, A., Tekinay, A. B., & Guler, M. O. (2016) · Wiley eBooks · doi:10.1002/9781118987483.ch10 · Cited by 1
Diagnosis of acute and chronic enteric fever using metabolomics
Näsström, E. (2017) · DiVA at Umeå University (Umeå University) · Cited by 1
Design of an Impedance-based, Gold Nanoparticle Enhanced Biosensor System
MacKay, S. (2017) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r3cj88061 · Cited by 1
Optical micro-manipulation in HIV-1 infected cells for improved HIV-1 treatment and diagnosis
Lugongolo, M. Y. (2020) · Unisa Institutional Repository (University of South Africa) · Cited by 1
Mahmoudi, M., Albalawi, M., Stanley, C., Berry, J. D., & Aljewari, H. (2026) · Preprints.org · doi:10.20944/preprints202603.1630.v1 · Cited by 1
ADVANCES IN DETECTING AND RESPONDING TO THREATS FROM BIOTERRORISM AND EMERGING VIRAL INFECTIONS
Morse, S., & Weber, A. M. (2013) · Wiley eBooks · doi:10.1002/9781118297469.ch15
DEVELOPMENTS AND CHALLENGES IN DIAGNOSTIC VIROLOGY
Barzon, L., Squarzon, L., Pacenti, M., & Palù, G. (2013) · Wiley eBooks · doi:10.1002/9781118297469.ch14
Rapid diagnostic tests used in first-step health services?
Güdücüoğlu, H. (2015) · Medical Science and Discovery · doi:10.17546/msd.46267
Sharma, R. K., Kumar, R., Sharma, N. B. B., Chhabra, R., Soni, G. R. ;. N. I. O. B. (. O. H. &. F. W., & Singh, S. (2015) · International Journal of Biomedical and Advance Research · doi:10.7439/ijbar.v6i10.2541
Real-time PCR and the ultimate quest for real-time results
Persing, D. H., & Baron, E. J. (2013) · Clinical Practice · doi:10.2217/cpr.13.89
Kong, N., Robinson, J. P., & Yang, F. (2013) · Purdue e-Pubs (Purdue University System)
Gottheil, R., & Mokwa, W. (2014) · RWTH Publications (RWTH Aachen)
Introduction to In Vitro Diagnostic Devices
Cheng, C., Kuan, C.-M., & Chen, C. (2015) · Springer eBooks · doi:10.1007/978-3-319-19737-1_1
The Role of Point-of-Care Test to Control Highly Pathogenic Avian Influenza in Indonesia
Tarigan, S. (2016) · Indonesian Bulletin of Animal and Veterinary Sciences · doi:10.14334/wartazoa.v26i1.1272
Antibiotic resistance among the AIDS-immunocompromised
DeNegre, A. A. (2016) · doi:10.7282/t3r49st0
The Role of Point-of-Care Testing in Travel Medicine
Martin, R., Perrone, L. A., & Noble, M. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-37506-1.00030-1
Microfluidic-based Point-of-Care Testing for Global Health
Laksanasopin, T. (2015) · doi:10.7916/d8tx3dfq
Vakkai, R. J. Y., Harris, K., & Crabbe, J. J. (2017) · International Journal of Noncommunicable Diseases · doi:10.4103/jncd.jncd_6_17
Technologies for a user-friendly microfluidic system for portable applications.
Kunota, T. T. R. (2015) · ResearchSpace (University of KwaZulu-Natal)
Chun, H. J., Han, Y. D., Kim, K. R., Lee, K. W., & Yoon, H. C. (2017) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2017.7994385
Su, P. (2016) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign)
Brazilian Program For HIV Point-Of-Care Test Evaluation: A Decade’s Experience
Ferreira, O. D. C., Véras, N. M. C., Pires, A. F., Bazzo, M. L., da Motta, L. R., Costa, D. A., Ribeiro, L. D. J., Benzaken, A. S., Mesquita, F., & Franchini, M. (2017) · International Archives of Medicine · doi:10.3823/2532
Advances in Point-of-Care Diagnostics for Infectious Disease
Natoli, M. E., Schwarz, R. A., Bond, M. M., Majors, C. E., Rohrman, B. A., Smith, C. A., & Richards-Kortum, R. R. (2018) · Springer eBooks · doi:10.1007/978-3-319-66647-1_1
Tuberculosis among Adults and the Determinants of Health
Khan, A. D., & Dean, H. D. (2017) · Oxford University Press eBooks · doi:10.1093/obo/9780199756797-0170
Perspective from Industry: AROMICS
Plasencia, C. (2018) · Springer eBooks · doi:10.1007/978-3-319-66647-1_5
Cenci, A. M. (2018) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.1007/s13631-018-0191-0
Colorimetric Detection of ssDNA using DNA-functionalized Gold Nanoparticles
Lam, M. (2016) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r32z1345z
Diagnosing and Treating Infectious Diseases and Antimicrobial Resistance Using Gold Nanoparticles
Mohamed, M. A. A. (2017) · TSpace (University of Toronto)
Rapid Diagnostic Tests for Syphilis
Mabey, D. C. W., Marks, M., & Peeling, R. W. W. (2019) · Wiley eBooks · doi:10.1002/9781119282686.ch6
Self-citationTrends in point-of-care microscopy
Bohidar, P., Gupta, S. S., & Banerjee, I. (2019) · Elsevier eBooks · doi:10.1016/b978-0-08-102420-1.00024-8
Minz, R., Singh, P., Tyagi, R., Singh, S., Sharma, A., & Aggarwal, R. (2019) · Indian Journal of Sexually Transmitted Diseases and AIDS · doi:10.4103/ijstd.ijstd_55_17
Thermally Enhanced Paper Microfluidics for Photonic Crystal Biosensors in Amorphous Silicon
Male, J. S. (2019) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York)
Micro- and Nanopore Technologies for Single-Cell Analysis
Tsutsui, M., Yanagida, T., Washio, T., & Kawai, T. (2020) · Springer eBooks · doi:10.1007/978-981-10-4857-9_36-1 · Cited by 1
Naville, R., Subtil, F., Sy, M., Marquis, M., Costes, P., & Letrilliart, L. (2020) · Family Practice · doi:10.1093/fampra/cmaa035
Responsive and Responsible Science, Technology, and Innovation for Global Health
Engel, N., Meershoek, A., & Krumeich, A. J. S. M. (2020) · Oxford University Press eBooks · doi:10.1093/oso/9780190949501.003.0015
Rashmi, K. S. (2016)
Love, F., Leopold, J. L., McMillin, B., & Su, F. (2021) · IEEE Annual International Computer Software and Applications Conference (COMPSAC) · doi:10.1109/compsac51774.2021.00145
Paper-based immunoassays for mobile healthcare: strategies, challenges, and future applications
Tsai, Y.-H., Yang, T., Shen, C., & Cheng, C. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-820534-1.00007-4
Mukuka, L., Theo, A., Zambwe, M., & Chipimo, P. J. (2021) · medRxiv · doi:10.1101/2021.12.20.21267838
Laboratory Techniques and Procedures
Fernández, F. Á. N. (2021) · Elsevier eBooks · doi:10.1016/b978-0-323-79412-1.00004-7
A Disposable DNA Analysis Chip with a Powerless ActuatorPreprint
Han, K., Kim, I., Chan, W. X., Kim, S., Kim, J.-H., Noh, J., Kim, N., & Yoon, Y. (2022) · Research Square · doi:10.21203/rs.3.rs-1122713/v1
Micro- and Nanopore Technologies for Single-Cell Analysis
Tsutsui, M., Yanagida, T., Washio, T., & Kawai, T. (2021) · Springer eBooks · doi:10.1007/978-981-10-8953-4_36
Salma Mahaboob, R., Obulesu, G., Srivastava, R. K., Murthy, R., Agarwal, P., & C, A. R. (2022) · Asian Journal of Medical Sciences · doi:10.3126/ajms.v13i3.40886
Bhargava, A., Nagia, S., Verma, P., Bansal, S., Khnuger, N., & Saxena, A. (2022) · Indian Journal of Sexually Transmitted Diseases and AIDS · doi:10.4103/ijstd.ijstd_30_22
New-Generation Molecular Techniques in POC Biosensors for Detection of Infectious Diseases
Vinayaka, A. C., Quyen, T. L., Golabi, M., Nguyen, T. B., Huynh, V. N., Bang, D. D., & Wolff, A. (2022) · Springer eBooks · doi:10.1007/978-981-19-5141-1_4
Nicolela, N. C. S. (2022) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.60.2022.tde-02032023-141856
Coonahan, E. S., Amaratunga, C., Long, C. A., & Tärning, J. (2023) · PLOS Global Public Health · doi:10.1371/journal.pgph.0002087
Nanomaterials-based biosensors for food and feed application
Russo, A., & Narayan, T. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-19146-6.00014-9
Investigating Molecular-based Micro-systems for Point of Care Applications in Food and Medicine
Diva, S. M. M. Z., Gill, P., & Rafati, A. (2023) · Research in Molecular Medicine · doi:10.32598/rmm.11.1.1275.1
Mukuka, L., Theo, A., Simushi, P., Zambwe, M., & Chipimo, P. J. (2025) · BMC Research Notes · doi:10.1186/s13104-024-07041-x
Adhana, S. (2025) · African Journal of Biomedical Research · doi:10.53555/ajbr.v26i3.7432
Wang, H., Yang, H., Li, C., Chen, M., Wang, X., Zhang, X., Gong, P., Zhang, N., Zhang, X., Li, J., et al. (2025) · Pathogens · doi:10.3390/pathogens14090918
Niu, M., Xu, X., Shi, Y., Zhang, X., Guan, P., Wang, Y., Dong, L., Chen, H., Huang, D., & Jin, C. (2025) · Frontiers in Public Health · doi:10.3389/fpubh.2025.1707432
Perkins, J., Nelson, S., Birley, E., McSwiggan, E., Dozier, M., McCarthy, A. R., Atkins, N., Agyei‐Manu, E., Rostron, J., Kameda, K., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26678120
Perkins, J., Nelson, S., Birley, E., McSwiggan, E., Dozier, M., McCarthy, A. R., Atkins, N., Agyei‐Manu, E., Rostron, J., Kameda, K., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26678099
Perkins, J., Nelson, S., Birley, E., McSwiggan, E., Dozier, M., McCarthy, A. R., Atkins, N., Agyei‐Manu, E., Rostron, J., Kameda, K., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26678093
Perkins, J., Nelson, S., Birley, E., McSwiggan, E., Dozier, M., McCarthy, A. R., Atkins, N., Agyei‐Manu, E., Rostron, J., Kameda, K., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26678105
Perkins, J., Nelson, S., Birley, E., McSwiggan, E., Dozier, M., McCarthy, A. R., Atkins, N., Agyei‐Manu, E., Rostron, J., Kameda, K., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26678108
Perkins, J., Nelson, S., Birley, E., McSwiggan, E., Dozier, M., McCarthy, A. R., Atkins, N., Agyei‐Manu, E., Rostron, J., Kameda, K., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26678096
Perkins, J., Nelson, S., Birley, E., McSwiggan, E., Dozier, M., McCarthy, A. R., Atkins, N., Agyei‐Manu, E., Rostron, J., Kameda, K., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26678102
Perkins, J., Nelson, S., Birley, E., McSwiggan, E., Dozier, M., McCarthy, A. R., Atkins, N., Agyei‐Manu, E., Rostron, J., Kameda, K., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26678117
Perkins, J., Nelson, S., Birley, E., McSwiggan, E., Dozier, M., McCarthy, A. R., Atkins, N., Agyei‐Manu, E., Rostron, J., Kameda, K., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26678111
Perkins, J., Nelson, S., Birley, E., McSwiggan, E., Dozier, M., McCarthy, A. R., Atkins, N., Agyei‐Manu, E., Rostron, J., Kameda, K., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26678114
Hydration Reaction-Powered DNA Analysis Kit for Non-Instrumented Point-of-Care Diagnostics
Han, K., Jang, S., Chan, W. X., Noh, J., Kim, N., & Yoon, Y.-J. (2025) · International Journal of Precision Engineering and Manufacturing-Green Technology · doi:10.1007/s40684-025-00811-3
Castro, M. D. M., Ismail, H. M., Montenegro-Quiñonez, C. A., Shilton, S., Denkinger, C. M., & Yerlikaya, S. (2026) · Research Square · doi:10.21203/rs.3.rs-8221943/v1
Quantum biosensing illuminates infected cells for timely disease diagnosis
Mthunzi-Kufa, P. T., & Mpofu, K. T. (2026) · Optics and Biophotonics in Low-Resource Settings · doi:10.1117/12.3081206
Huayanay-Espinoza, C. A., Morán, D., Albitres‐Flores, L., Bernabé‐Ortiz, A., Cahuana-Hurtado, L., Vetter, B., Safary, E., & Lazo-Porras, M. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-104570
Intaramat, A., Binmaeil, H., Bunsong, T., Deekae, S., Chayangsu, S., Fuangthong, M., Nguitragool, W., Burtnick, M. N., Brett, P. J., & Chantratita, N. (2026) · Microbiology Spectrum · doi:10.1128/spectrum.02881-25
Améliorer la prescription médicamenteuse grâce à des mécanismes économiques?
Michel-Lepage, A. (2016) · theses.fr (ABES) · doi:10.70675/13300fa6z3a02z4ae4zaf80z178496882b2d
Reshmi, K. S., Raj, S., Subramanium, R., Nair, V. R., & Mehta, A. A. (2026) · Journal of PACS · doi:10.5005/jpacs-11047-0027
SpiroTact and VIPER technology: a promising rapid point-of-care test for active syphilis
Mdingi, M. M., Gigi, R. M. S., Jung, H., Kalk, M., Burton, M., & Gazendam, J. A. C. (2026) · Sexually Transmitted Infections · doi:10.1136/sextrans-2025-056901
Saleh, K. A., Ali, N. T., Ali, G. S., Ali, H. M., & Alkubati, S. A. (2026) · Scientific Reports · doi:10.21203/rs.3.rs-9145541/v1
Perkins, J. E., Sørensen, J. B., Islam, M. S., Hovda, K. E., Chowdhury, F. R., Ghose, A., Rahman, A. S. M. M., Eddleston, M., & Street, A. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-114864
Hassan, Y. M., El-Tantawi, H. G., Ali, I. H., & Attia, M. S. (2026) · Talanta · doi:10.1016/j.talanta.2026.130103
Oropouche virus: viral evolution, epidemiological trends, and challenges for control
Huits, R. M. H. G., Mileno, M. D., & Norman, F. F. (2026) · Current Opinion in Infectious Diseases · doi:10.1097/qco.0000000000001212
Painter, C., Phommasone, K., Mayxay, M., & Ashley, E. A. (2026) · BMJ Public Health · doi:10.1136/bmjph-2025-003523
Evolving Cosmetic Regulations in the World
Tahir, M., Sohail, A., Khalid, H., & Khan, H. (2026) · International Journal of Innovations in Science and Technology · doi:10.33411/ijist/1738
Martin, C. D., Gummalla, N., Shimazu, K. N., Bender, A. T., & Posner, J. D. (2026) · Sensors & Diagnostics · doi:10.1039/d6sd00044d
Phurijaruyangkun, S., Tangjitrungrot, P., Pongparit, S., Wattanakul, N., Jantrapanukorn, B., Veeramano, R., Augkarawaritsawong, S., Kumkrong, K., Sirothot, T., Jaratsing, P., et al. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27156575
Pari, P., Chellamuthu, L., Krishnakumar, J., & Sivam, R. K. R. (2026) · International Journal of Academic Medicine · doi:10.4103/ijam.ijam_20_26
Olomiekido, D. O.-O. G., Chidubem, D. O. A., Ojeamiren, I., Pajapati, A. K., Azeke, O. D., & Olowo, P. S. S. (2026) · British Journal of Contemporary Research · doi:10.67693/bjcr-jzl5yjc9
Huzaifa, M., & Hassan, S. W. (2026) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2026.117614
Yes/No Quantitative Analysis of Single-Stranded Oligonucleotides with Lateral Flow Assays
Hassandoost, N., Munoz, L., Kotecki, K., & Nesterova, I. V. (2026) · Biosensors · doi:10.3390/bios16090465
Microfluidics devices for viral disease detection
Saha, R., Kumar, S., Vajpayee, M., & Manoharan, K. (2026) · Progress in molecular biology and translational science · doi:10.1016/bs.pmbts.2026.08.016
Gurnani, B., & Kaur, K. (2026) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2026.2733166
A review of portable molecular diagnostics: Paper and smartphone synergy for pathogen detection
Lee, S., Batule, B. S., & Seok, Y. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119238
DNA detection using metal-enhanced fluorescence
Khattab, A., Allam, M., Mouhamed, A. A., Yousry, A., Mahmoud, A. M., & Ewaisha, R. (2026) · RSC Advances · doi:10.1039/d6ra05164b
Gupta, P., Bijalwan, S., Kalita, D., & Mittal, G. (2026) · Cureus · doi:10.7759/cureus.117107
Metadata
- Authors
- Peeling, R. W., & Mabey, D.
- Affiliations
- London School of Hygiene & Tropical Medicine (GB)
- Corresponding author
- Peeling, R.W.
- Venue
- Clinical Microbiology and Infection
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 16
- Issue
- 8
- Pages
- 1062-1069
- ISSN
- 1198-743X (ISSN-L)
- OpenAlex
- W1748737970
- Cited by
- 500
- References
- 56
- Citations by year
- 2026: 31 · 2025: 19 · 2024: 30 · 2023: 20 · 2022: 23 · 2021: 27 · 2020: 45 · 2019: 37 · 2018: 47 · 2017: 36 · 2016: 44 · 2015: 45 · 2014: 29 · 2013: 32 · 2012: 18
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Clinical Microbiology and Infection (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Wellcome Trust
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Keywords
- point-of-care testing, infectious disease diagnosis, developing countries, malaria diagnosis, HIV testing, syphilis testing, diagnostic test regulation, syndromic management
- MeSH terms
- Developing Countries, Education, Medical, Continuing, Humans, Malaria, Quality Control, Syphilis, HIV Infections, Point-of-Care Systems, Molecular Diagnostic Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review