Assessing mechanical function of the zygomatic region in macaques: validation and sensitivity testing of finite element models
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Crucial to the interpretation of the results of any finite element analysis of a skeletal system is a test of the validity of the results and an assessment of the sensitivity of the model parameters. We have therefore developed finite element models of two crania of Macaca fascicularis and investigated their sensitivity to variations in bone material properties, the zygomatico‐temporal suture and the loading regimen applied to the zygomatic arch. Maximum principal strains were validated against data derived from ex vivo strain gauge experiments using non‐physiological loads applied to the macaque zygomatic arch. Elastic properties of the zygomatic arch bone and the zygomatico‐temporal suture obtained by nanoindentation resulted in a high degree of congruence between experimental and simulated strains. The findings also indicated that the presence of a zygomatico‐temporal suture in the model produced strains more similar to experimental values than a completely separated or fused arch. Strains were distinctly higher when the load was applied through the modelled superficial masseter compared with loading an array of nodes on the arch. This study demonstrates the importance of the accurate selection of the material properties involved in predicting strains in a finite element model. Furthermore, our findings strongly highlight the influence of the presence of craniofacial sutures on strains experienced in the face. This has implications when investigating craniofacial growth and masticatory function but should generally be taken into account in functional analyses of the craniofacial system of both extant and extinct species.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanoindentation mapping of the mechanical properties of human molar tooth enamel
Cuy, J. L., Mann, A. B., Livi, K. J., Teaford, M. F., & Weihs, T. P. (2002) · Archives of Oral Biology · doi:10.1016/s0003-9969(02)00006-7 · Cited by 721 · cited 1×
“The teeth were assigned an elastic modulus E of 70 GPa based on a mean of published values for enamel and dentine (Cuy et al. 2002; Kinney et al. 2003).”
MethodMechanical Testing of Bone and the Bone-Implant Interface
(1999) · CRC Press eBooks · doi:10.1201/9781420073560 · Cited by 709
Kinney, J. H., Marshall, S. J., & Marshall, G. W. (2003) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/154411130301400103 · Cited by 701 · cited 1×
“The teeth were assigned an elastic modulus E of 70 GPa based on a mean of published values for enamel and dentine (Cuy et al. 2002; Kinney et al. 2003).”
MethodThe Mechanical Properties of Cortical Bone
REILLY, D. T., & BURSTEIN, A. H. (1974) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197456050-00012 · Cited by 653 · cited 1×
“Several studies have suggested that formalin fixation changes, to some extent, the material properties of bone (Reilly & Burstein, 1974; Zioupos et al. 2000).”
BackgroundVariations in cortical material properties throughout the human dentate mandible
Schwartz‐Dabney, C. L., & Dechow, P. C. (2003) · American Journal of Physical Anthropology · doi:10.1002/ajpa.10121 · Cited by 314 · cited 2×
“species and anatomical region) and the preservation should ideally be considered as well (Dechow & Hylander, 2000; Zioupos et al. 2000; Peterson & Dechow, 2003; Schwartz-Dabney & Dechow, 2003; Marinescu et al. 2005; Strait et al. 2005).”
BackgroundMargulies, S. S., & Thibault, K. L. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1287160 · Cited by 306 · cited 3×
“Thus, the cranial sutures of neonate and young rats and pigs have Young’s moduli ranging between 0.64 and 171.5 MPa (Margulies & Thibault, 2000; McLaughlin et al. 2000; Tanaka et al. 2000).”
BackgroundInfluentialMechanical properties of cranial sutures
Jaslow, C. R. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90059-c · Cited by 284 · cited 4×
“Flexible sutures are also said to act as shockabsorbers, being able to absorb more impact energy than bone (Buckland-Wright, 1978; Jaslow, 1990).”
BackgroundInfluentialStrait, D. S., Wang, Q., Dechow, P. C., Ross, C. F., Richmond, B. G., Spencer, M. A., & Patel, B. A. (2005) · The Anatomical Record Part A: Discoveries in Molecular, Cellular, and Evolutionary Biology · doi:10.1002/ar.a.20172 · Cited by 263 · cited 20×
“Moreover, the effect of changes in bone stiffness on the distribution of strains in the zygomatic arch and the circumorbital region are investigated by sequential alteration in the FEA of the experimentally determined Young’s modulus of elasticity ( E , GPa) of bone and these effects are compared with our strain gauge…”
BackgroundMethodResultInfluentialFinite element analysis in functional morphology
Richmond, B. G., Wright, B. W., Grosse, I., Dechow, P. C., Ross, C. F., Spencer, M. A., & Strait, D. S. (2005) · The Anatomical Record Part A: Discoveries in Molecular, Cellular, and Evolutionary Biology · doi:10.1002/ar.a.20169 · Cited by 255 · cited 17×
“Moreover, the effect of changes in bone stiffness on the distribution of strains in the zygomatic arch and the circumorbital region are investigated by sequential alteration in the FEA of the experimentally determined Young’s modulus of elasticity ( E , GPa) of bone and these effects are compared with our strain gauge…”
BackgroundInfluentialHylander, W. L., & Johnson, K. R. (1997) · American Journal of Physical Anthropology · doi:10.1002/(sici)1096-8644(199702)102:2<203::aid-ajpa5>3.0.co;2-z · Cited by 218 · cited 14×
“The zygomatic arch resembles to some extent a beam with fixed ends, to which a uniform but off-centre load has been applied ( Hylander & Johnson, 1997 ).”
BackgroundMethodResultInfluential
Cited by
Rayfield, E. J. (2007) · Annual Review of Earth and Planetary Sciences · doi:10.1146/annurev.earth.35.031306.140104 · Cited by 474
Requirements for comparing the performance of finite element models of biological structures
Dumont, E. R., Grosse, I. R., & Slater, G. J. (2009) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2008.08.017 · Cited by 323
The feeding biomechanics and dietary ecology of Australopithecus africanus
Strait, D. S., Weber, G. W., Neubauer, S., Chalk, J., Richmond, B. G., Lucas, P. W., Spencer, M. A., Schrein, C., Dechow, P. C., Ross, C. F., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0808730106 · Cited by 250
Functional Evolution of the Feeding System in Rodents
Cox, P. G., Rayfield, E. J., Fagan, M. J., Herrel, A., Pataky, T. C., & Jeffery, N. (2012) · PLoS ONE · doi:10.1371/journal.pone.0036299 · Cited by 243
“Although originally developed as an engineering tool, FEA has been widely used in recent years to model stress and strain in complex biological objects, frequently vertebrate skulls [29–33].”
MethodSelf-citationvon Cramon-Taubadel, N. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1113050108 · Cited by 211
The craniomandibular mechanics of being human
Wroe, S., Ferrara, T. L., McHenry, C. R., Curnoe, D., & Chamoli, U. (2010) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.0509 · Cited by 165
“Applying our protocols for FEM generation and previously applied boundary conditions, provides results which are largely in agreement with experimentally derived findings (Kupczik et al. 2007).”
MethodResultInfluentialPolly, P. D., Stayton, C. T., Dumont, E. R., Pierce, S. E., Rayfield, E. J., & Angielczyk, K. D. (2016) · Journal of Vertebrate Paleontology · doi:10.1080/02724634.2016.1111225 · Cited by 164
“Experimental strains may be recorded in vivo (e.g., Strait et al., 2005; Ross et al., 2011) or ex vivo (see Kupczik et al., 2007; Bright and Rayfield, 2011) using strain gauges, digital speckle interferometry, or photoelastic materials (e.g., Anderson and Rayfield, 2012; Gr€oning et al., 2012).”
BackgroundSupraorbital morphology and social dynamics in human evolution
Godinho, R. M., Spikins, P., & O’Higgins, P. (2018) · Nature Ecology & Evolution · doi:10.1038/s41559-018-0528-0 · Cited by 73
Self-citation
Metadata
- Authors
- Kupczik, K., Dobson, C. A., Fagan, M. J., Crompton, R. H., Oxnard, C. E., & O’Higgins, P.
- Venue
- Journal of Anatomy
- Publisher
- Wiley
- Published
- 2006-12-12
- Volume
- 210
- Issue
- 1
- Pages
- 41-53
- ISSN
- 0021-8782 (ISSN-L)
- 1469-7580
- OpenAlex
- W2021388277
- Cited by
- 168
- References
- 35
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.