Pulse Transit Time and Blood Pressure: An Intensive Analysis
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Relationships between pulse transit time (PTT) and intra‐arterial systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP) were examined in 4 subjects under three conditions: rest, paced respiration, and mental arithmetic. PTT was measured from the EKG R‐wave to two peripheral pulses (brachial and radial) and from one pulse to the other. Three points on each pulse wave were used (peak, foot, slope) in the measurements, yielding nine different measures of PTT. The nine PTT measures were not consistently intercorrelated. PTTs initiated by the R‐wave were moderately correlated with SBP, but not with DBP or MAP. Brachial to radial PTTs were not correlated with any measures of BP. Relationships between PTT and BP also varied from subject to subject. The limited magnitude of the correlations and their inconsistency suggest caution in the simple substitution of PTT for beat‐to‐beat measures of BP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pre‐ejection Period: Measuring Beta‐adrenergic Influences Upon the Heart
Newlin, D. B., & Levenson, R. W. (1979) · Psychophysiology · doi:10.1111/j.1469-8986.1979.tb01519.x · Cited by 275
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“The foot location may be strictly defined as the diastolic minimum time [43], [47], [132], [133].”
BackgroundMethodInfluentialPulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418
“The association between pulse transit time and BP was studied extensively in the field of psychophysiology (9, 11, 19, 33, 37) in the 1970s and 1980s, and more recently by Ochiai et al.”
BackgroundMethodInfluentialOscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Wong, M. Y.-M., Poon, C. C.-Y., & Zhang, Y.-T. (2009) · Cardiovascular Engineering · doi:10.1007/s10558-009-9070-7 · Cited by 191
Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera
Jeong, I. C., & Finkelstein, J. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0439-z · Cited by 160
Metadata
- Authors
- Lane, J. D., Greenstadt, L., Shapiro, D., & Rubinstein, E.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1983-01
- Volume
- 20
- Issue
- 1
- Pages
- 45-49
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2054808190
- Cited by
- 107
- References
- 1
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulse Transit Time and Blood Pressure: An Intensive Analysis. https://app.cochat.ai/papers/10.1111/j.1469-8986.1983.tb00899.x
- The paper
- Lane, J. D., Greenstadt, L., Shapiro, D., & Rubinstein, E. (1983). Pulse Transit Time and Blood Pressure: An Intensive Analysis. Psychophysiology. https://doi.org/10.1111/j.1469-8986.1983.tb00899.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.