CoChat

Data‐dependent filter characteristics of peak‐valley respiratory sinus arrhythmia estimation: A cautionary note

BYRNE, EVAN A., PORGES, STEPHEN W. · 1993 · Psychophysiology
Cited by 31

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Filter characteristics of the peak‐valley respiratory sinus arrhythmia estimation method are described. To identify filter characteristics of this method, models were generated that combined signals of different frequencies with trends of varying slopes. These models simulate the influence of trend and changing respiratory frequency on the accuracy of peak‐valley estimates. The transfer function of the peak‐valley method, unlike that of other time domain filters, is not solely dependent upon signal frequency. Two factors interact to determine the relative accuracy of the peak‐valley method: (a) slope of the signal component and (b) slope of the underlying trend. Combinations of these factors may result in significant distortion to the input signal. The direction of error is a function of the direction of the trend (i.e., overestimation with deceleration and underestimation with acceleration). In many situations when respiratory sinus arrhythmia amplitude is low in special populations (e.g., cardiovascular disorders, high‐risk infants, or human fetuses) or under conditions that greatly reduce respiratory sinus arrhythmia amplitude (e.g., exercise, drugs, pharmacological manipulations), use of the peak‐valley method may result in significant measurement error. The use of this method to evaluate respiratory sinus arrhythmia over short epochs (i.e., less than 2 min) or to quantify changes in respiratory sinus arrhythmia due to discrete stimulation (e.g., breath by breath) may result in inconsistent measurement error. Recommendations are made for detrending heart rate data prior to application of the peak‐valley method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1469-8986.1993.tb02061.x

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 31

Metadata

Authors
BYRNE, E. A., & PORGES, S. W.
Venue
Psychophysiology
Publisher
Wiley
Published
1993-07
Volume
30
Issue
4
Pages
397-404
ISSN
  • 0048-5772 (ISSN-L)
  • 1469-8986
OpenAlex
W2132879803
Cited by
31
References
7
FWCI
1.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Data‐dependent filter characteristics of peak‐valley respiratory sinus arrhythmia estimation: A cautionary note. https://app.cochat.ai/papers/10.1111/j.1469-8986.1993.tb02061.x
The paper
BYRNE, E. A., & PORGES, S. W. (1993). Data‐dependent filter characteristics of peak‐valley respiratory sinus arrhythmia estimation: A cautionary note. Psychophysiology. https://doi.org/10.1111/j.1469-8986.1993.tb02061.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.