Ambulatory monitoring of the impedance cardiogram
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The wowing need for more advanced ambulatory monitoring has led lo the development of an ambulatory monitor for impedance cardiography (VU‐AMD). This paper presents two studies addressing the validity of the VU‐AMD. In the first study, the cardiovascular responses of 25 subjects during various conditions were simultaneously recorded with the VU‐AMD and a standard laboratory impedance device. Correlations between the responses of the ambulatory and laboratory devices were high, both inter and intraindividually, except lot stroke volume and cardiac output during exercise In the second study, 26 subjects underwent 24‐hr monitoring with the VU‐AMD. The values obtained with the VU‐AMD were realistic and varied in a predictable way over activity and posture. It is concluded that the VU‐AMD is a valid device for the measurement of systolic time intervals in real‐life situations but its applicability for absolute stroke volume and cardiac output determination remains lo he established.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130
Pre‐ejection Period: Measuring Beta‐adrenergic Influences Upon the Heart
Newlin, D. B., & Levenson, R. W. (1979) · Psychophysiology · doi:10.1111/j.1469-8986.1979.tb01519.x · Cited by 275
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“But, in general, the more convenient the waveform measurement is, the more noise contamination can be expected [51]– [62].”
BackgroundInfluentialLicht, C. M. M., de Geus, E. J. C., Zitman, F. G., Hoogendijk, W. J. G., van Dyck, R., & Penninx, B. W. J. H. (2008) · Archives of General Psychiatry · doi:10.1001/archpsyc.65.12.1358 · Cited by 379
Licht, C. M. M., de Geus, E. J. C., Seldenrijk, A., van Hout, H. P. J., Zitman, F. G., van Dyck, R., & Penninx, B. W. J. H. (2009) · Hypertension · doi:10.1161/hypertensionaha.108.126698 · Cited by 319
Ambulatory measurement of respiratory sinus arrhythmia and respiration rate
de Geus, E. J. C., Willemsen, G. H. M., Klaver, C. H. A. M., & van Doornen, L. J. P. (1995) · Biological Psychology · doi:10.1016/0301-0511(95)05137-6 · Cited by 313
Self-citationNelson, B. W., & Allen, N. B. (2019) · JMIR mHealth and uHealth · doi:10.2196/10828 · Cited by 310
Metadata
- Authors
- Willemsen, G. H. M., DeGeus, E. J. C., Klaver, C. H. A. M., VanDoornen, L. J. P., & Carrofl, D.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1996-03
- Volume
- 33
- Issue
- 2
- Pages
- 184-193
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2076878115
- Cited by
- 222
- References
- 2
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ambulatory monitoring of the impedance cardiogram. https://app.cochat.ai/papers/10.1111/j.1469-8986.1996.tb02122.x
- The paper
- Willemsen, G. H. M., DeGeus, E. J. C., Klaver, C. H. A. M., VanDoornen, L. J. P., & Carrofl, D. (1996). Ambulatory monitoring of the impedance cardiogram. Psychophysiology. https://doi.org/10.1111/j.1469-8986.1996.tb02122.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.