Ambulatory monitoring of the impedance cardiogram
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The wowing need for more advanced ambulatory monitoring has led lo the development of an ambulatory monitor for impedance cardiography (VU‐AMD). This paper presents two studies addressing the validity of the VU‐AMD. In the first study, the cardiovascular responses of 25 subjects during various conditions were simultaneously recorded with the VU‐AMD and a standard laboratory impedance device. Correlations between the responses of the ambulatory and laboratory devices were high, both inter and intraindividually, except lot stroke volume and cardiac output during exercise In the second study, 26 subjects underwent 24‐hr monitoring with the VU‐AMD. The values obtained with the VU‐AMD were realistic and varied in a predictable way over activity and posture. It is concluded that the VU‐AMD is a valid device for the measurement of systolic time intervals in real‐life situations but its applicability for absolute stroke volume and cardiac output determination remains lo he established.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130
Handbook of stress, reactivity, and cardiovascular disease
Matthews, K. A. (1986) · Wiley eBooks · Cited by 531
The Minnesota impedance cardiograph- theory and applications.
Kubicek, W. G., Kottke, J., Ramos, M. U., PATTERSON, R. P., Witsoe, D. A., LaBree, J. W., Remole, W., Layman, T. E., Schoening, H., & Garamela, J. T. (1974) · PubMed · Cited by 396
Heart rate and muscle sympathetic nerve variability during reflex changes of autonomic activity
Saul, J. P., Rea, R. F., Eckberg, D. L., Berger, R. D., & Cohen, R. J. (1990) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1990.258.3.h713 · Cited by 343
Sherwood, A., Allen, M. T., Obrist, P. A., & Langer, A. W. (1986) · Psychophysiology · doi:10.1111/j.1469-8986.1986.tb00602.x · Cited by 292
Pickering, T. G., & Gerin, W. (1990) · Annals of Behavioral Medicine · doi:10.1207/s15324796abm1201_1 · Cited by 276
Pre‐ejection Period: Measuring Beta‐adrenergic Influences Upon the Heart
Newlin, D. B., & Levenson, R. W. (1979) · Psychophysiology · doi:10.1111/j.1469-8986.1979.tb01519.x · Cited by 275
Harris, W. S., Schoenfeld, C. D., & Weissler, A. M. (1967) · Journal of Clinical Investigation · doi:10.1172/jci105661 · Cited by 266
Estimation of energy expenditure by a portable accelerometer
MONTOYE, H. J., WASHBURN, R., SERVAIS, S., ERTL, A., WEBSTER, J. G., & NAGLE, F. J. (1983) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198315050-00010 · Cited by 225
Thakor, N. V., Webster, J. G., & Tompkins, W. J. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478504 · Cited by 150
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“But, in general, the more convenient the waveform measurement is, the more noise contamination can be expected [51]– [62].”
BackgroundInfluentialLicht, C. M. M., de Geus, E. J. C., Zitman, F. G., Hoogendijk, W. J. G., van Dyck, R., & Penninx, B. W. J. H. (2008) · Archives of General Psychiatry · doi:10.1001/archpsyc.65.12.1358 · Cited by 379
Licht, C. M. M., de Geus, E. J. C., Seldenrijk, A., van Hout, H. P. J., Zitman, F. G., van Dyck, R., & Penninx, B. W. J. H. (2009) · Hypertension · doi:10.1161/hypertensionaha.108.126698 · Cited by 319
Ambulatory measurement of respiratory sinus arrhythmia and respiration rate
de Geus, E. J. C., Willemsen, G. H. M., Klaver, C. H. A. M., & van Doornen, L. J. P. (1995) · Biological Psychology · doi:10.1016/0301-0511(95)05137-6 · Cited by 313
Self-citationNelson, B. W., & Allen, N. B. (2019) · JMIR mHealth and uHealth · doi:10.2196/10828 · Cited by 310
Kunz-Ebrecht, S. R., Mohamed-Ali, V., Feldman, P. J., Kirschbaum, C., & Steptoe, A. (2003) · Brain, Behavior, and Immunity · doi:10.1016/s0889-1591(03)00029-1 · Cited by 288
Bosch, J. A., de Geus, E. J. C., Veerman, E. C. I., Hoogstraten, J., & Nieuw Amerongen, A. V. (2003) · Psychosomatic Medicine · doi:10.1097/01.psy.0000058376.50240.2d · Cited by 248
“Ambulatory Monitoring System (VU-AMS) device (38, 39).”
Self-citationLicht, C. M. M., Vreeburg, S. A., van Reedt Dortland, A. K. B., Giltay, E. J., Hoogendijk, W. J. G., DeRijk, R. H., Vogelzangs, N., Zitman, F. G., de Geus, E. J. C., & Penninx, B. W. J. H. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2009-2801 · Cited by 240
“The PEP was defined as the interval from the B point (upstroke) to the X point (incisura) of the dZ/dt signal, as described in detail elsewhere (31).”
MethodLongitudinal Evidence for Unfavorable Effects of Antidepressants on Heart Rate Variability
Licht, C. M. M., de Geus, E. J. C., van Dyck, R., & Penninx, B. W. J. H. (2010) · Biological Psychiatry · doi:10.1016/j.biopsych.2010.06.032 · Cited by 225
Licht, C. M. M., de Geus, E. J. C., van Dyck, R., & Penninx, B. W. J. H. (2009) · Psychosomatic Medicine · doi:10.1097/psy.0b013e3181a292a6 · Cited by 215
“The VU-AMS is a light-weight ambulatory device that records the ECG and changes in thorax impedance (dZ) from six electrodes placed on the chest and back of the subjects (34,35).”
BackgroundSchuurmans, A. A. T., de Looff, P., Nijhof, K. S., Rosada, C., Scholte, R. H. J., Popma, A., & Otten, R. (2020) · Journal of Medical Systems · doi:10.1007/s10916-020-01648-w · Cited by 210
“Although the reliability and validity of the VU-AMS to obtain HRV parameters has been established [4, 5], there is”
BackgroundInfluentialBakvis, P., Roelofs, K., Kuyk, J., Edelbroek, P. M., Swinkels, W. A. M., & Spinhoven, P. (2009) · Epilepsia · doi:10.1111/j.1528-1167.2008.01862.x · Cited by 195
Ergonomics, user comfort, and performance in standard and robot-assisted laparoscopic surgery
van der Schatte Olivier, R. H., van‘t Hullenaar, C. D. P., Ruurda, J. P., & Broeders, I. A. M. J. (2009) · Surgical Endoscopy · doi:10.1007/s00464-008-0184-6 · Cited by 193
“It could be worn beneath clothing, allowing the subject complete freedom of movement [12, 28, 32].”
BackgroundComparison of time and frequency domain measures of RSA in ambulatory recordings
Goedhart, A. D., Van Der Sluis, S., Houtveen, J. H., Willemsen, G., & De Geus, E. J. C. (2007) · Psychophysiology · doi:10.1111/j.1469-8986.2006.00490.x · Cited by 180
Self-citationLight and Diurnal Cycle Affect Human Heart Rate: Possible Role for the Circadian Pacemaker
Scheer, F. A. J. L., van Doornen, L. J. P., & Buijs, R. M. (1999) · Journal of Biological Rhythms · doi:10.1177/074873099129000614 · Cited by 173
“HR was determined from electrocardiography recordings by an ambulatory measuring system (AMS, Psychonomy, Free University , Amsterdam, the Netherlands) (de Geus and van Doornen, 1996; Willemsen et al., 1996).”
MethodInfluentialSelf-citationImpedance pneumography: Noise as signal in impedance cardiography
Ernst, J. M., Litvack, D. A., Lozano, D. L., Cacioppo, J. T., & Berntson, G. G. (1999) · Psychophysiology · doi:10.1017/s0048577299981003 · Cited by 168
A General Enhancement of Autonomic and Cortisol Responses During Social Evaluative Threat
Bosch, J. A., de Geus, E. J. C., Carroll, D., Goedhart, A. D., Anane, L. A., Veldhuizen van Zanten, J. J., Helmerhorst, E. J., & Edwards, K. M. (2009) · Psychosomatic Medicine · doi:10.1097/psy.0b013e3181baef05 · Cited by 164
Houtveen, J. H., Rietveld, S., & de Geus, E. J. C. (2002) · Psychophysiology · doi:10.1111/1469-8986.3940427 · Cited by 160
Sack, M., Lempa, W., Steinmetz, A., Lamprecht, F., & Hofmann, A. (2008) · Journal of Anxiety Disorders · doi:10.1016/j.janxdis.2008.01.007 · Cited by 123
Self-esteem levels and cardiovascular and inflammatory responses to acute stress.
O’Donnell, K., Brydon, L., Wright, C. E., & Steptoe, A. (2008) · Brain, Behavior, and Immunity · doi:10.1016/j.bbi.2008.06.012 · Cited by 118
“Continuous measurements over 5 min were recorded and the mean taken to provide an average heart rate value (Willemsen et al., 1996).”
Burgess, H. J., Sletten, T., Savic, N., Gilbert, S. S., & Dawson, D. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.3.1214 · Cited by 94
“Reliability and validity of the VU-AMS is described elsewhere (11, 36).”
Cardiovascular activity during laboratory tasks in women with high and low worry
Knepp, M. M., & Friedman, B. H. (2008) · Biological Psychology · doi:10.1016/j.biopsycho.2008.07.002 · Cited by 50
Oosterman, M., Schuengel, C., Forrer, M. L., & De Moor, M. H. M. (2019) · Development and Psychopathology · doi:10.1017/s0954579418001591 · Cited by 38
“In the current study, PEP was included as an indicator of sympathetic reactivity and RSA was included as an indicator of parasympathetic reactivity of the ANS (Sherwood et al., 1990; Willemsen et al., 1996).”
MethodBusscher, B., Spinhoven, P., van Gerwen, L. J., & de Geus, E. J. C. (2013) · Behaviour Research and Therapy · doi:10.1016/j.brat.2012.10.009 · Cited by 34
“The HR, PEP and RSAmeasures are uniquely qualified to meet these demands (Goedhart et al., 2006; Willemsen et al., 1996).”
BackgroundThe time course of the inflammatory response to the Salmonella typhi vaccination
Paine, N. J., Ring, C., Bosch, J. A., Drayson, M. T., & Veldhuijzen van Zanten, J. J. C. S. (2013) · Brain, Behavior, and Immunity · doi:10.1016/j.bbi.2013.01.004 · Cited by 32
The effects of day‐time exogenous melatonin administration on cardiac autonomic activity
Harris, A. S., Burgess, H. J., & Dawson, D. (2001) · Journal of Pineal Research · doi:10.1034/j.1600-079x.2001.310302.x · Cited by 29
Schäflein, E., Sattel, H., Schmidt, U., & Sack, M. (2018) · European Journal of Psychotraumatology · doi:10.1080/20008198.2018.1472991 · Cited by 28
Idiodynamic profiles of cardiovascular activity: A P-technique approach
Friedman, B. H., & Santucci, A. K. (2003) · Integrative Physiological & Behavioral Science · doi:10.1007/bf02688859 · Cited by 15
Metadata
- Authors
- Willemsen, G. H. M., DeGeus, E. J. C., Klaver, C. H. A. M., VanDoornen, L. J. P., & Carrofl, D.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1996-03
- Volume
- 33
- Issue
- 2
- Pages
- 184-193
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2076878115
- Cited by
- 222
- References
- 23
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.