Automatic removal of eye movement and blink artifacts from EEG data using blind component separation
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Signals from eye movements and blinks can be orders of magnitude larger than brain‐generated electrical potentials and are one of the main sources of artifacts in electroencephalographic (EEG) data. Rejecting contaminated trials causes substantial data loss, and restricting eye movements/blinks limits the experimental designs possible and may impact the cognitive processes under investigation. This article presents a method based on blind source separation (BSS) for automatic removal of electroocular artifacts from EEG data. BBS is a signal‐processing methodology that includes independent component analysis (ICA). In contrast to previously explored ICA‐based methods for artifact removal, this method is automated. Moreover, the BSS algorithm described herein can isolate correlated electroocular components with a high degree of accuracy. Although the focus is on eliminating ocular artifacts in EEG data, the approach can be extended to other sources of EEG contamination such as cardiac signals, environmental noise, and electrode drift, and adapted for use with magnetoencephalographic (MEG) data, a magnetic correlate of EEG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Fast Fixed-Point Algorithm for Independent Component Analysis
Hyvärinen, A., & Oja, E. (1997) · Neural Computation · doi:10.1162/neco.1997.9.7.1483 · Cited by 3,391
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
A blind source separation technique using second-order statistics
Belouchrani, A., Abed-Meraim, K., Cardoso, J.-F., & Moulines, E. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.554307 · Cited by 2,775
Blind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Lee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967
A multiple source approach to the correction of eye artifacts
Berg, P., & Scherg, M. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90094-9 · Cited by 696 · cited 2×
“A more advanced method ( Berg & Scherg, 1994 ) that combines source modeling, PCA, and artifact averaging provides an improvement on the individual techniques above but requires a substantial amount of calibration data and prior modeling of artifact production and event-related activities.”
MethodExtraction of ocular artefacts from EEG using independent component analysis
Vigário, R. N. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00042-8 · Cited by 639
Ocular artifacts in EEG and event-related potentials I: Scalp topography
Lins, O. G., Picton, T. W., Berg, P., & Scherg, M. (1993) · Brain Topography · doi:10.1007/bf01234127 · Cited by 323
Lins, O. G., Picton, T. W., Berg, P., & Scherg, M. (1993) · Brain Topography · doi:10.1007/bf01234128 · Cited by 225
Dipole models of eye movements and blinks
Berg, P., & Scherg, M. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90154-v · Cited by 200
Berg, P., & Scherg, M. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/a/010 · Cited by 169
Arnaud Delorme, A., Makeig, S., B, T. J. S. A., & Pines, N. T. (2001) · Cited by 154
Dealing with artifacts: The EOG contamination of the event-related brain potential
Gratton, G. (1998) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03209415 · Cited by 142 · cited 2×
“Other methods seek to correct for ocular artifacts in the data; these include subtraction or regression in the time or frequency domain (see Gratton, 1998, for a review) and methods that model the electrooculogram (EOG) components to isolate them from the I.F.G. was supported by a grant from NSF…”
MethodIndependent Components of Magnetoencephalography: Localization
Tang, A. C., Pearlmutter, B. A., Malaszenko, N. A., Phung, D. B., & Reeb, B. C. (2002) · Neural Computation · doi:10.1162/089976602760128036 · Cited by 123
SVD based technique for noise reduction in electroencephalographic signals
Puthusserypady, S. K., & Dutt, D. N. (1996) · Signal Processing · doi:10.1016/s0165-1684(96)00129-6 · Cited by 95
Methodological considerations for the evaluation of spatio-temporal source models
Achim, A., Richer, F., & Saint-Hilaire, J. M. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90140-y · Cited by 77
Distribution of eye movement and eyeblink potentials over the scalp.
Overton, D. A., & Shagass, C. (1969) · PubMed · Cited by 70
Cited by
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759
“…for separating distinct artifactual processes including eye blink, muscle and electrical artifacts (Barbati et al., 2004; Delorme et al., 2001; Iriarte et al., 2003; James and Gibson, 2003; Joyce et al., 2004; Jung et al., 2000b; Tran et al., 2004; Urrestarazu et al., 2004; Zhukov et al., 2000).”
BackgroundMethodADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Chaumon, M., Bishop, D. V. M., & Busch, N. A. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.02.025 · Cited by 833
Removal of Artifacts from EEG Signals: A Review
Jiang, X., Bian, G.-B., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 826
Metadata
- Authors
- Joyce, C. A., Gorodnitsky, I. F., & Kutas, M.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 2003-12
- Volume
- 41
- Issue
- 2
- Pages
- 313-325
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2169064120
- Cited by
- 596
- References
- 17
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.