Controlled trial of fundal height measurement plotted on customised antenatal growth charts

Gardosi, Jason, Francis, Andre·1999·BJOG: An International Journal of Obstetrics & Gynaecology

Abstract

Objective The purpose of this study was to evaluate the effect of a policy of standard antenatal care which included plotting fundal height measurements on customised antenatal charts in the community. Design Prospective, non‐randomised, controlled, population‐based study. Population Two defined and separate referral areas from community to teaching hospital, with similar delivery rates and socioeconomic characteristics. A total of 1272 consecutively booked women with singleton pregnancies and dating ultrasound scans before 22 weeks of gestation. Intervention In the study area customised fundal height charts were issued to each mother at the routine hospital booking scan, on which regular fundal height measurements were to be plotted by community midwives. The charts adjusted limits according to maternal characteristics including height, weight, parity and ethnic group. Usual management in the control area included fundal height assessment by abdominal palpation and recording on a standard co‐operation card. Outcome measures Antenatal detection of small and large for gestational age babies; number of antenatal investigations for fetal growth in each group. Results The study group had a significantly higher antenatal detection rate of small for gestational age babies (48%vs 29%, odds ratio 2.2, 95% confidence interval 1.145) and large for gestational age babies (46%vs 24%, OR 2.6, CI 1.3–5.5). There was no increase in the study group in the overall number of scans per pregnancy done in the ultrasound department (1.2 vs 1.3, P= 0.14), but a slight decrease in repeat (two or more) third trimester scans (OR 0.8, CI 0.6–11.0, P= 0.08). Women in the study group had significantly fewer referrals for investigation in a pregnancy assessment centre (OR 0.7, CI 0.5–0.9; P= 0.01) and fewer admissions to the antenatal ward (OR 0.6, CI 0.4–0.7, P= 0.001). There were no differences in perinatal outcome. Conclusions Serial measurement of fundal height plotted on customised charts leads to increased antenatal detection of small and large babies. This is accompanied by fewer investigations, which is likely to represent increased confidence in the community to recognise normal fetal growth. With adjustments for physiological variables, fundal height measurements appear to be a cost effective screening method which can result in substantial improvements in the antenatal assessment of fetal growth.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1471-0528.1999.tb08267.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 172

Metadata

Authors
Gardosi, J., & Francis, A.
Venue
BJOG: An International Journal of Obstetrics & Gynaecology
Publisher
Wiley
Published
1999-04
Volume
106
Issue
4
Pages
309-317
ISSN
  • 0306-5456 (ISSN-L)
  • 1470-0328
  • 1471-0528
OpenAlex
W2168599832
Cited by
172
References
3
FWCI
4.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Controlled trial of fundal height measurement plotted on customised antenatal growth charts. https://app.cochat.ai/papers/10.1111/j.1471-0528.1999.tb08267.x
The paper
Gardosi, J., & Francis, A. (1999). Controlled trial of fundal height measurement plotted on customised antenatal growth charts. BJOG: An International Journal of Obstetrics & Gynaecology. https://doi.org/10.1111/j.1471-0528.1999.tb08267.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.