The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Pilocarpine iontophoresis test: an index of physiological sweat secretion?
Abstract
Pilocarpine iontophoresis test: an index of physiological sweat secretion? Summary. The pilocarpine iontophoresis test (P‐test) is used as a predictor of the capacity to produce sweat. Therefore, we studied the reproducibility of this test in 12 normal subjects on 10 consecutive days. Furthermore, we determined whether the P‐test reflects whole‐body and regional sweat secretion during exercise in the heat. Finally, we determined whether the P‐test stimulates the eccrine sweat glands to maximal sweat secretion. Six growth hormone‐deficient (GHD) patients who are known to have decreased sweating, and 11 healthy control subjects were studied. To induce maximal sweat secretion, the patients exercised on a bicycle ergometer at a workload corresponding to 40% of their maximal aerobic power (VO 2 max). The 11 healthy subjects exercised at a workload of 150 W. All subjects exercised for 60 min in ambient air at 35°C, with 50% relative humidity. The P‐test showed a mean day‐to‐day variation of 20‐8% between individual subjects. There was a significant positive correlation between the P‐test and regional sweat secretion (r 2 =0.74). The correlation coefficient (r 2 ) was 0.50 for the correlation between the P‐test and whole‐body sweat secretion, and 0.52 for the correlation between regional sweat secretion and whole‐body sweat secretion. We conclude that the pilocarpine iontophoresis test reflects heat‐ and exercise‐induced sweating capacity. However, this test does not induce maximal sweating, and it cannot be used as a single reliable predictor of whole‐body sweating, due to considerable day‐to‐day variation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Forearm sweating rate is higher with exercise and/or thermal stress compared with pilocarpine iontophoresis.
“Forearm sweating rate has been reported to be higher with exercise and/or thermal stress compared with pilocarpine iontophoresis (Hjortskov et al. 1995; Vimieiro-Gomes et al. 2005).”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Hjortskov et al. 1995
Citations
Cites
Gibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434
Impaired thermoregulation in adults with growth hormone deficiency during heat exposure and exercise
Juul, A., Behrenscheer, A., Tims, T., Nielsen, B., Halkjær-Kristensen, J., & Skakkebæk, N. E. (1993) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1993.tb01001.x · Cited by 53
Self-citationREDUCED SWEATING IN ADULTS WITH GROWTH HORMONE DEFICIENCY
Pedersen, S., Welling, K., Michaelsen, K. F., Gensen, J., Christiansen, J. S., & Skakkebæk, N. E. (1989) · The Lancet · doi:10.1016/s0140-6736(89)90930-6 · Cited by 48
Self-citationInfluence of sex and growth hormone deficiency on sweating
Main, K. M., NILSSON, K. O., & Skakkebæk, N. E. (1991) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519109091642 · Cited by 30
Self-citation
Flagged first, then by citations
Research works printed but not linked: 1
- Kuno Y., 1956, Human Perspiration.
Cited by
Sorted by citations
Baker, L. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0691-5 · Cited by 403
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
Barnes, K. A., Anderson, M. L., Stofan, J. R., Dalrymple, K. J., Reimel, A. J., Roberts, T. J., Randell, R. K., Ungaro, C. T., & Baker, L. B. (2019) · Journal of Sports Sciences · doi:10.1080/02640414.2019.1633159 · Cited by 132
Comparison of sweat rate during graded exercise and the local rate induced by pilocarpine
Vimieiro-Gomes, A. C., Magalhães, F. C., Amorim, F. T., Machado-Moreira, C. A., Rosa, M. S., Lima, N. R. V., & Rodrigues, L. O. C. (2005) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2005000700017 · Cited by 49
Metadata
- Authors
- Hjortskov, N., Jepsen, L. T., Nielsen, B., Juul, A., & Skakkebæk, N. E.
- Affiliations
- University of Copenhagen (DK)
- ORCID
- Venue
- Clinical Physiology
- Publisher
- Wiley
- Published
- 1995-07
- Volume
- 15
- Issue
- 4
- Pages
- 409-414
- ISSN
- 0144-5979 (ISSN-L)
- 1365-2281
- OpenAlex
- W2051819643
- Cited by
- 19
- References
- 4
- Citations by year
- 2025: 1 · 2024: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 2 · 2018: 1 · 2017: 2 · 2015: 1 · 2013: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Physiology (publishedVersion)
- PubMed (publishedVersion)
- Research at the University of Copenhagen (University of Copenhagen) (publishedVersion)
- Research at the University of Copenhagen (University of Copenhagen) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Dermatology › Sympathectomy and Hyperhidrosis Treatments
- Keywords
- sweat secretion, eccrine sweat glands, growth hormone deficiency, heat stress, exercise-induced sweating, test reproducibility, day-to-day variability
- MeSH terms
- Adult, Exercise Test, Female, Hot Temperature, Humans, Humidity, Iontophoresis, Male, Oxygen Consumption, Pilocarpine, Sweating, Exercise, Muscarinic Agonists
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›