Learning effect of isokinetic measurements in healthy subjects, and reliability and comparability of Biodex and Lido dynamometers
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Summary: The aim of this study was to examine the learning effect during a set of isokinetic measurements, to evaluate the reliability of the Biodex System 3 PRO dynamometer, and to compare the Biodex System 3 PRO and the Lido Active dynamometers on both extension and flexion over the elbow and the knee at 60° s−1. Thirteen (nine women, four men) healthy participants were measured five times using the Biodex and once using the Lido dynamometer. The intervals between the first four tests were 20 min, and 1 week between tests 4 and 5. Between Biodex and Lido measurements there was a 20 min time interval. When comparing the first five measurements (Biodex), no systematic effect over time and an excellent reliability were found with respect to elbow and knee flexion and extension. No difference in muscle strength (Nm) between the Biodex and Lido was observed for knee flexion (P = 0·59), knee extension (P = 0·18) and elbow extension (P = 0·63). However, elbow flexion showed a 14·8% (95% CI: 11·2–18·4%; P = 0·0001) higher peak torque on Biodex. In conclusion, no learning effect was observed and the Biodex proved to be a highly reliable isokinetic dynamometer. A difference was observed when comparing Biodex and Lido on elbow flexion, but the difference did not outrange the expected variation found with a typical isokinetic measurement, which is why both sets of equipment seem applicable in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
The Design and Analysis of Clinical Experiments
Fleiss, J. L. (1999) · Wiley eBooks · doi:10.1002/9781118032923 · Cited by 4,819
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779 · cited 1×
“In this way, the statistics are unaffected by variation in the measured data (Stratford & Goldsmith, 1997; Atkinson & Nevill, 1998).”
MethodThe Design and Analysis of Clinical Experiments.
Hills, M., & Fleiss, J. L. (1987) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2982050 · Cited by 3,261
Statistics Notes: Measurement error
Bland, J. M., & Altman, D. G. (1996) · BMJ · doi:10.1136/bmj.313.7059.744 · Cited by 1,070
Valovich-mcLeod, T. C., Shultz, S. J., Gansneder, B. M., Perrin, D. H., & Drouin, J. M. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0933-0 · Cited by 839 · cited 3×
“One device that is often applied, the Biodex, is shown in two earlier studies to give a very good reliability, thus fulfilling the first criteria for reliability, i.e. a reliable device (Taylor et al., 1991; Drouin et al., 2004).”
MethodResultAn Approach to the Analysis of Repeated Measurements
Diggle, P. J. (1988) · Biometrics · doi:10.2307/2531727 · Cited by 490 · cited 1×
“…correlation between measurements on the same subject, we used the model proposed by P.J. Diggle, in which you extend the random intercept model (splitplot model) to incorporate correlation between pairs of measurements according to the distance in time between the measurements (Diggle, 1988).”
MethodStratford, P. W., & Goldsmith, C. H. (1997) · Physical Therapy · doi:10.1093/ptj/77.7.745 · Cited by 455 · cited 1×
“In this way, the statistics are unaffected by variation in the measured data (Stratford & Goldsmith, 1997; Atkinson & Nevill, 1998).”
MethodAssessing intrarater, interrater, and test-retest reliability of continuous measurements
Rousson, V., Gasser, T., & Seifert, B. (2002) · Statistics in Medicine · doi:10.1002/sim.1253 · Cited by 415 · cited 1×
“If one suspects a learning effect, a poor reliability following only one or very few sets of measurements in the procedure might be found (Rousson et al., 2002).”
BackgroundInfluentialTest-Retest Reliability of the Biodex Isokinetic Dynamometer
Feiring, D. C., Ellenbecker, T. S., & Derscheid, G. L. (1990) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.1990.11.7.298 · Cited by 359 · cited 3×
“In this case the apparatus was used for measuring healthy subjects performing a test similar to the procedure applied when measuring patients (Montgomery et al., 1989; Feiring et al., 1990; Gross et al., 1991).”
BackgroundMethodResultKnee extensor strength, activation, and size in very elderly people following strength training
Harridge, S. D. R., Kryger, A., & Stensgaard, A. (1999) · Muscle & Nerve · doi:10.1002/(sici)1097-4598(199907)22:7<831::aid-mus4>3.0.co;2-3 · Cited by 322 · cited 1×
“A study of very old people (85–97 years old) showed a muscle strength improvement of between 17 and 100% or more (Harridge et al., 1999), and this improvement might be more than 100% for younger subjects.”
BackgroundIsokinetic Dynamometry: Applications and Limitations
Baltzopoulos, V., & Brodie, D. A. (1989) · Sports Medicine · doi:10.2165/00007256-198908020-00003 · Cited by 283
The effects of a physical training program on patients with osteoarthritis of the knees
Røgind, H., Bibow-Nielsen, B., Jensen, B., Møller, H. C., Frimodt-Møller, H., & Bliddal, H. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90238-6 · Cited by 270 · cited 1×
“To avoid possible confusion with the apparatus per se, an initial measurement was performed, as indicated in studies of both normal subjects and patients with osteoarthritis of the knee (Rogind et al., 1998).”
MethodSelf-citationDostal, W. F., Soderberg, G. L., & Andrews, J. G. (1986) · Physical Therapy · doi:10.1093/ptj/66.3.351 · Cited by 234 · cited 4×
“The following two dynamometers were applied in this study: For testing learning effect and reliability a Biodex System 3 PRO (Biodex Medical System, New York, NY, USA) was applied.”
MethodInfluentialPincivero, D., Lephart, S., & Karunakara, R. (1997) · International Journal of Sports Medicine · doi:10.1055/s-2007-972605 · Cited by 229 · cited 2×
“, 2004) and the reliability of isokinetic measurements in clinical settings (Montgomery et al., 1989; Feiring et al., 1990; Gross et al., 1991; Pincivero et al., 1997).”
BackgroundResultStatic and dynamic assessment of the Biodex dynamometer
Taylor, N. A. S., Sanders, R. H., Howick, E. I., & Stanley, S. N. (1991) · European Journal of Applied Physiology · doi:10.1007/bf00643739 · Cited by 159 · cited 2×
“One device that is often applied, the Biodex, is shown in two earlier studies to give a very good reliability, thus fulfilling the first criteria for reliability, i.e. a reliable device (Taylor et al., 1991; Drouin et al., 2004).”
MethodReliability of Measurements of Concentric and Eccentric Isokinetic Loading
Tredinnick, T. J., & Duncan, P. W. (1988) · Physical Therapy · doi:10.1093/ptj/68.5.656 · Cited by 136 · cited 1×
“Earlier studies indicate acceptable reliability for various kinds of isokinetic devices, such as Cybex (Bandy & McLaughlin, 1993), KinCom (Tredinnick & Duncan, 1988), MERAC (Capranica et al., 1998).”
MethodReliability of an Isokinetic Test of Muscle Strength and Endurance
Montgomery, L. C., Douglass, L. W., & Deuster, P. A. (1989) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1989.10.8.315 · Cited by 127 · cited 2×
“In this case the apparatus was used for measuring healthy subjects performing a test similar to the procedure applied when measuring patients (Montgomery et al., 1989; Feiring et al., 1990; Gross et al., 1991).”
BackgroundMethodDomholdt, E. (1993) · Cited by 95
Gross, M. T., Huffman, G. M., Phillips, C. N., et al. (1991) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1991.13.6.329 · Cited by 82 · cited 6×
“The highest reproducibility for measured isokinetic muscle strength is achieved at velocities below 100 s)1 (Baltzopoulos & Brodie, 1989; Thompson et al., 1989; Gross et al., 1991).”
BackgroundMethodResultInfluentialKremer, J. N., & Nixon, S. W. (1978) · Ecological studies · doi:10.1007/978-3-642-66717-6_12 · Cited by 81
Madsen, O. R. (1996) · European Journal of Applied Physiology · doi:10.1007/bf00377442 · Cited by 62 · cited 4×
“Earlier studies of the reliability of isokinetic measurements on patients and healthy subjects showed a low reliability, as indicated by a high critical difference (CD ¼ z0Æ05 · 2 · CV, z0Æ05 ¼ 1Æ96, CV ¼ coefficient of variance) (Madsen & Lauridsen, 1995; Madsen, 1996; Madsen & Brot, 1996).”
BackgroundResultInfluentialIntramachine and Intermachine Reliability for Selected Dynamic Muscle Performance Tests
Bandy, W. D., & McLaughlin, S. (1993) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1993.18.5.609 · Cited by 58 · cited 1×
“Earlier studies indicate acceptable reliability for various kinds of isokinetic devices, such as Cybex (Bandy & McLaughlin, 1993), KinCom (Tredinnick & Duncan, 1988), MERAC (Capranica et al., 1998).”
MethodMadsen, O. R., & Lauridsen, U. B. (1995) · Journal of Rehabilitation Medicine · doi:10.2340/165019771995219226 · Cited by 24
The Reliability of Two Different Cybex Isokinetic Systems
Thigpen, L. K., Blanke, D., & Lang, P. (1990) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1990.12.4.157 · Cited by 24 · cited 1×
“Earlier studies of the variation show CV% from 6% (Francis & Hoobler, 1987) up to 30% (Thigpen et al., 1990).”
BackgroundMadsen, O. R., & Brot, C. (1996) · Clinical Rheumatology · doi:10.1007/bf02230333 · Cited by 22 · cited 2×
“Earlier studies of the reliability of isokinetic measurements on patients and healthy subjects showed a low reliability, as indicated by a high critical difference (CD ¼ z0Æ05 · 2 · CV, z0Æ05 ¼ 1Æ96, CV ¼ coefficient of variance) (Madsen & Lauridsen, 1995; Madsen, 1996; Madsen & Brot, 1996).”
BackgroundResult
Cited by
Danneskiold‐Samsøe, B., Bartels, E. M., Bülow, P. M., Lund, H., Stockmarr, A., Holm, C. C., Wätjen, I., Appleyard, M., & Bliddal, H. (2009) · Acta Physiologica · doi:10.1111/j.1748-1716.2009.02022.x · Cited by 280
Self-citationReliability of isokinetic strength imbalance ratios measured using the Cybex NORM dynamometer
Impellizzeri, F. M., Bizzini, M., Rampinini, E., Cereda, F., & Maffiuletti, N. A. (2008) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2007.00786.x · Cited by 279
Lund, H., Weile, U., Christensen, R., Rostock, B., Downey, A., Bartels, E., Danneskiold-Samsøe, B., & Bliddal, H. (2008) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0134 · Cited by 218
Self-citationTrans, T., Aaboe, J., Henriksen, M., Christensen, R., Bliddal, H., & Lund, H. (2009) · The Knee · doi:10.1016/j.knee.2008.11.014 · Cited by 193
“Muscle strength Maximal voluntary muscle strength of hamstrings and the quadriceps muscles was measured by isokinetic dynamometry at 30°/s, 60°/s, and 90°/s (Biodex System 3 PRO, Biodex Medical System, NY, USA) as previously described [22].”
MethodSelf-citationde Araujo Ribeiro Alvares, J. B., Rodrigues, R., de Azevedo Franke, R., da Silva, B. G. C., Pinto, R. S., Vaz, M. A., & Baroni, B. M. (2015) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2014.04.004 · Cited by 190
Metadata
- Authors
- Lund, H., Søndergaard, K., Zachariassen, T., Christensen, R., Bülow, P., Henriksen, M., Bartels, E. M., Danneskiold‐Samsøe, B., & Bliddal, H.
- Venue
- Clinical Physiology and Functional Imaging
- Publisher
- Wiley
- Published
- 2005-02-23
- Volume
- 25
- Issue
- 2
- Pages
- 75-82
- ISSN
- 1475-0961 (ISSN-L)
- 1475-097X
- OpenAlex
- W2023715489
- Cited by
- 173
- References
- 27
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.