The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Computer vision syndrome: a review of ocular causes and potential treatments
Abstract
Citation information : Rosenfield M. Computer vision syndrome: a review of ocular causes and potential treatments. Ophthalmic Physiol Opt 2011, 31 , 502–515. doi: 10.1111/j.1475‐1313.2011.00834.x Computer vision syndrome (CVS) is the combination of eye and vision problems associated with the use of computers. In modern western society the use of computers for both vocational and avocational activities is almost universal. However, CVS may have a significant impact not only on visual comfort but also occupational productivity since between 64% and 90% of computer users experience visual symptoms which may include eyestrain, headaches, ocular discomfort, dry eye, diplopia and blurred vision either at near or when looking into the distance after prolonged computer use. This paper reviews the principal ocular causes for this condition, namely oculomotor anomalies and dry eye. Accommodation and vergence responses to electronic screens appear to be similar to those found when viewing printed materials, whereas the prevalence of dry eye symptoms is greater during computer operation. The latter is probably due to a decrease in blink rate and blink amplitude, as well as increased corneal exposure resulting from the monitor frequently being positioned in primary gaze. However, the efficacy of proposed treatments to reduce symptoms of CVS is unproven. A better understanding of the physiology underlying CVS is critical to allow more accurate diagnosis and treatment. This will enable practitioners to optimize visual comfort and efficiency during computer operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2007) · The Ocular Surface · doi:10.1016/s1542-0124(12)70081-2 · Cited by 3,267
Prevalence of dry eye syndrome among US women
Schaumberg, D. A., Sullivan, D. A., Buring, J. E., & Dana, M. R. (2003) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(03)00218-6 · Cited by 1,225
Prevalence of and Risk Factors for Dry Eye Syndrome
Moss, S. E. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.9.1264 · Cited by 1,222
Computer Vision Syndrome: A Review
Blehm, C., Vishnu, S., Khattak, A., Mitra, S., & Yee, R. W. (2005) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2005.02.008 · Cited by 860
Etiology, prevalence, and treatment of dry eye disease
Gayton, J. (2009) · Clinical Ophthalmology · doi:10.2147/opth.s5555 · Cited by 582
Prevalence of Dry Eye Disease Among US Men: Estimates From the Physicians' Health Studies
Schaumberg, D. A. (2009) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2009.103 · Cited by 551
Dry Eyes and Video Display Terminals
Tsubota, K., & Nakamori, K. (1993) · New England Journal of Medicine · doi:10.1056/nejm199302253280817 · Cited by 435
Ergonomics, musculoskeletal disorders and computer work
Wahlström, J. (2005) · Occupational Medicine · doi:10.1093/occmed/kqi083 · Cited by 422
Prevalence of Dry Eye Disease among Japanese Visual Display Terminal Users
Uchino, M., Schaumberg, D. A., Dogru, M., Uchino, Y., Fukagawa, K., Shimmura, S., Satoh, T., Takebayashi, T., & Tsubota, K. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2008.06.022 · Cited by 393
HENNING, R. A., JACQUES, P., KISSEL, G. V., SULLIVAN, A. B., & ALTERAS-WEBB, S. M. (1997) · Ergonomics · doi:10.1080/001401397188396 · Cited by 351
Sheedy, J. E., HAYES, J., & ENGLE, A. J. (2002) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2002.tb04090.x · Cited by 306
Font Size and Viewing Distance of Handheld Smart Phones
Bababekova, Y., Rosenfield, M., Hue, J. E., & Huang, R. R. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e3182198792 · Cited by 277
Self-citationLong‐term Incidence of Dry Eye in an Older Population
Moss, S. E., Klein, R., & Klein, R. (2008) · Optometry and Vision Science · doi:10.1097/opx.0b013e318181a947 · Cited by 266
Computer Use, Symptoms, and Quality of Life
HAYES, J. R., SHEEDY, J. E., STELMACK, J. A., & HEANEY, C. A. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e31812f7546 · Cited by 246
Blinking and Tear Break-Up During Four Visual Tasks
Himebaugh, N. L., Begley, C. G., Bradley, A., & Wilkinson, J. A. (2009) · Optometry and Vision Science · doi:10.1097/opx.0b013e318194e962 · Cited by 228
Schlote, T., Kadner, G., & Freudenthaler, N. (2004) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-003-0845-z · Cited by 210
ACOSTA, M. C., GALLAR, J., & BELMONTE, C. (1999) · Experimental Eye Research · doi:10.1006/exer.1998.0656 · Cited by 182
Video display terminal use and reported health symptoms among Massachusetts clerical workers.
Rossignol, A. M., Ep, M., Vm, S., & Pagnotto, L. D. (1987) · PubMed · Cited by 176
Eye problems and visual display terminals--the facts and the fallacies
Thomson, W. (1998) · Ophthalmic and Physiological Optics · doi:10.1016/s0275-5408(97)00067-7 · Cited by 163
Psychological factors and visual fatigue in working with video display terminals
Mocci, F., Serra, A., & Corrias, G. A. (2001) · Occupational and Environmental Medicine · doi:10.1136/oem.58.4.267 · Cited by 162
Proof-reading texts on screen and paper
WRIGHT, P., & Lickorish, A. (1983) · Behaviour and Information Technology · doi:10.1080/01449298308914479 · Cited by 145
Accommodation response and visual discomfort
Tosha, C., Borsting, E. J., Ridder, W. H., & Chase, C. (2009) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2009.00687.x · Cited by 143
Contact lens correction of presbyopia
Bennett, E. S. (2008) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2007.00242.x · Cited by 142
A comparison of symptoms after viewing text on a computer screen and hardcopy
Chu, C. A., Rosenfield, M., Portello, J. K., Benzoni, J. A., & Collier, J. D. (2010) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2010.00802.x · Cited by 124
Self-citationProof-reading: VDU and paper text compared for speed, accuracy and fatigue
Wilkinson, R. T., & Robinshaw, H. M. (1987) · Behaviour and Information Technology · doi:10.1080/01449298708901822 · Cited by 95
Efficacy of Office Ergonomics Education
Bohr, P. C. (2000) · Journal of Occupational Rehabilitation · doi:10.1023/a:1009464315358 · Cited by 87
Accommodation and convergence during sustained computer work
Collier, J. D., & Rosenfield, M. (2011) · Optometry · doi:10.1016/j.optm.2010.10.013 · Cited by 86
Self-citationThe Mallett Fixation Disparity Test: influence of test instructions and relationship with symptoms
Karania, R., & Evans, B. J. W. (2006) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2006.00385.x · Cited by 74
Blinking Patterns and Corneal Staining
Collins, M. J., Iskander, D. R., Saunders, A., Hook, S., Anthony, E., & Gillon, R. S. (2006) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/01.icl.0000224551.58399.9a · Cited by 69
Diagnosing and Treating Computer-Related Vision Problems
(2003) · Elsevier eBooks · doi:10.1016/b978-0-7506-7404-1.x5001-1 · Cited by 60
Working conditions, visual fatigue, and mental health among systems analysts in São Paulo, Brazil.
Rocha, L. E., & Debert-Ribeiro, M. (2004) · PubMed · Cited by 50
Optometric Management of Nearpoint Vision Disorders
Birnbaum, M. H. (2008) · Cited by 47
[Risk factors for asthenopia among computer terminal operators].
Sánchez‐Román, F. R., Pérez-Lucio, C., Juárez-Ruíz, C., Vélez-Zamora, N. M., & Villarruel, M. J. (1996) · PubMed · Cited by 43
Work with video display terminals among office employees. III. Ophthalmologic factors.
Böös, S., Calissendorff, B., KNAVE, B. G., Nyman, K., & Voss, M. (1985) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.2207 · Cited by 40
Wilkins, A. J. (1986) · Trends in Neurosciences · doi:10.1016/0166-2236(86)90106-2 · Cited by 31
Fixation disparity at different viewing distances of a visual display unit
Jaschinski, W. (1993) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1993.tb00422.x · Cited by 29
Associations between Gender, Ocular Parameters and Diseases: The Beijing Eye Study
Xu, L., You, Q. S., Wang, Y. X., & Jonas, J. B. (2010) · Ophthalmic Research · doi:10.1159/000321522 · Cited by 19
Cited by
Digital eye strain: prevalence, measurement and amelioration
Sheppard, A. L., & Wolffsohn, J. S. (2018) · BMJ Open Ophthalmology · doi:10.1136/bmjophth-2018-000146 · Cited by 731
Seguí, M. D. M., Cabrero-García, J., Crespo, A., Verdú, J., & Ronda, E. (2015) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2015.01.015 · Cited by 398
Digital Pathology: Advantages, Limitations and Emerging Perspectives
Jahn, S. W., Plass, M., & Moinfar, F. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9113697 · Cited by 348
Management of digital eye strain
Coles‐brennan, C., Sulley, A., & Young, G. (2019) · Clinical and Experimental Optometry · doi:10.1111/cxo.12798 · Cited by 324
Digital Eye Strain- A Comprehensive Review
Kaur, K., Gurnani, B., Nayak, S., Deori, N., Kaur, S., Jethani, J., Singh, D., Agarkar, S., Hussaindeen, J. R., Sukhija, J., et al. (2022) · Ophthalmology and Therapy · doi:10.1007/s40123-022-00540-9 · Cited by 313
Metadata
- Authors
- Rosenfield, M.
- Venue
- Ophthalmic and Physiological Optics
- Published
- 2011-04-12
- Volume
- 31
- Issue
- 5
- Pages
- 502-515
- ISSN
- 0275-5408 (ISSN-L)
- 1475-1313
- OpenAlex
- W1490164115
- Cited by
- 726
- References
- 37
- FWCI
- 21.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.