Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology
Open accessAbstract
Citation information : McAlinden C, Khadka J & Pesudovs K. Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology. Ophthalmic Physiol Opt 2011, 31 , 330–338. doi: 10.1111/j.1475‐1313.2011.00851.x The ever‐expanding choice of ocular metrology and imaging equipment has driven research into the validity of their measurements. Consequently, studies of the agreement between two instruments or clinical tests have proliferated in the ophthalmic literature. It is important that researchers apply the appropriate statistical tests in agreement studies. Correlation coefficients are hazardous and should be avoided. The ‘limits of agreement’ method originally proposed by Altman and Bland in 1983 is the statistical procedure of choice. Its step‐by‐step use and practical considerations in relation to optometry and ophthalmology are detailed in addition to sample size considerations and statistical approaches to precision (repeatability or reproducibility) estimates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“This was consistent with recommendations from McAlinden et al that sample sizes for agreement studies should include at least 100 subjects(McAlinden et al., 2011).”
From Acceptability and Concordance of Self- Versus Clinician- Sampling for HPV Testing among Rural South Indian Women (2021) · cites this paper as McAlinden et al., 2011
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Scheffé, H. (1960) · Soil Science · doi:10.1097/00010694-196006000-00016 · Cited by 5,625
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Comprehensive Textbook of Psychiatry
Schwab, J. J. (1968) · Psychosomatics · doi:10.1016/s0033-3182(68)71813-2 · Cited by 1,291
Measurement reliability and agreement in psychiatry
Shrout, P. E. (1998) · Statistical Methods in Medical Research · doi:10.1177/096228029800700306 · Cited by 1,211
Clinical biostatistics: LIV. The biostatistics of concordance
Kramer, M. S., & Feinstein, A. R. (1981) · Clinical Pharmacology & Therapeutics · doi:10.1038/clpt.1981.18 · Cited by 1,087
Improving the Reliability of the Pelli-Robson Contrast Sensitivity Test
Bullimore, M. A., Elliott, D. B., & Bailey, I. L. (1991) · Noninvasive Assessment of the Visual System · doi:10.1364/navs.1991.md12 · Cited by 257
Cited by
Sorted by citations
Items 301–400 of 433
Şahinoğlu, E., Ergin, G., Bakırhan, S., & Ünver, B. (2023) · Clinical and Experimental Health Sciences · doi:10.33808/clinexphealthsci.1038122 · Cited by 4
Chirapapaisan, C., Eiamsamarng, A., Chirapapaisan, N., Raksong, W., Sakiyalak, D., Koodkaew, S., & Subunnasenee, A. (2024) · PLoS ONE · doi:10.1371/journal.pone.0304169 · Cited by 4
Comparison of two visual-verbal tests of ocular motility using an eye-tracker
FUENTE, C. L. D. L., Saz-Onrubia, E., & Sánchez-Cano, A. I. (2024) · Journal of Optometry · doi:10.1016/j.optom.2024.100517 · Cited by 4
Zhou, Y., He, X., Liu, Z., Xu, L., Li, L., Chen, J., Zhao, J., Li, R., Yan, C., Yu, C., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-66540-w · Cited by 4
Ma, S., Sun, J., Yang, J. S., Wen, K., Chen, X., Zhao, F., Gao, R.-Y., Zhengda Guangming Eye Group, W. 2., & Tian, F. (2024) · International Journal of Ophthalmology · doi:10.18240/ijo.2024.08.08 · Cited by 4
Ali, S., Maddipatla, D., Bazuin, B. J., & Atashbar, M. Z. (2024) · IEEE Journal on Flexible Electronics · doi:10.1109/jflex.2024.3515919 · Cited by 4
Validation of a New Software Application for Tear Breakup Measurement
Pena‐Verdeal, H., Ramos, L., García-Queiruga, J., García‐Resúa, C., Giraldez, M. J., & Yebra‐Pimentel, E. (2021) · Optometry and Vision Science · doi:10.1097/opx.0000000000001852 · Cited by 4
Enders, C., Baeurle, F., Lang, G. E., Dreyhaupt, J., Trick, S., Lang, G. K., & Werner, J. U. (2019) · Klinische Monatsblätter für Augenheilkunde · doi:10.1055/a-1002-0045 · Cited by 4
Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT
Tañá‐Rivero, P., Ruíz-Mesa, R., Aguilar-Córcoles, S., Tello-Elordi, C., Ramos-Alzamora, M., & Montés‐Micó, R. (2021) · Journal of Optometry · doi:10.1016/j.optom.2021.04.001 · Cited by 4
Bafna, R. K., Mahalingam, K., Rakheja, V., Sharma, N., Gupta, S., Daniel, R. A., & Gupta, V. (2021) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_930_21 · Cited by 4
Refractive Lens Exchange Surgery in Early-Onset High Myopia Patients With Partial Cataract
Zhang, X.-F., Li, X., Chen, X., Kline, B., Kang, M., Li, M., Ying, H., & Wang, N. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.739197 · Cited by 4
Gaurisankar, Z. S., van Rijn, G. A., Luyten, G. P. M., & Beenakker, J. M. (2020) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-020-04874-7 · Cited by 4
Software-dependent processing variability in SPECT functional parameters: Clinical implications
Malhotra, S., & Soman, P. (2016) · Journal of Nuclear Cardiology · doi:10.1007/s12350-016-0438-y · Cited by 4
Comparison of venous and calculated blood gas values to arterial values in critically ill patients
Lumholdt, M., Andreasen, J. B., Damgaard, K. A., Christensen, E. F., Leutscher, P. D. C., & Rasmussen, B. S. (2024) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.14555 · Cited by 3
Xu, Q., Li, Y., Li, X., Wen, Y., Tang, T., Qu, J., Zhao, M., & Wang, K. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102337 · Cited by 3
Martínez-Albert, N., Nieto-Fernández, J. C., & García‐Marqués, J. V. (2025) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-025-06893-8 · Cited by 3
Montés‐Micó, R., Nilsson, M., Brautaset, R., Venkataraman, A. P., & Domínguez‐Vicent, A. (2025) · Journal of Refractive Surgery · doi:10.3928/1081597x-20241230-03 · Cited by 3
Yokoyama, H., Shibagaki, K., Arai, S., Williams, H. E., Vette, A. H., Nomura, T., & Milosevic, M. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108154 · Cited by 3
Mustafa, M. M. S. M., Mutalib, H. A., Halim, N. A., & Hilmi, M. R. (2020) · Sains Malaysiana · doi:10.17576/jsm-2020-4906-21 · Cited by 3
Özcan, Y., Talıpınar, S., Kayıran, A., & Türe, U. (2021) · European Journal of Ophthalmology · doi:10.1177/11206721211028035 · Cited by 3
Toric Intraocular Lenses for the Management of Corneal Astigmatism at the Time of Cataract Surgery
McAlinden, C., & Janicek, D. (2021) · Journal of Ophthalmology · doi:10.1155/2021/3286043 · Cited by 3
Self-citationAssessing the reliability of web-based measurements of visual function
Leadbeater, R. J., McGraw, P. V., & Ledgeway, T. (2023) · Behavior Research Methods · doi:10.3758/s13428-022-02057-2 · Cited by 3
Foveal neural adaptation to optically induced contrast reduction
Roth, A., Breher, K., Domdei, N., & Wahl, S. (2024) · Journal of Vision · doi:10.1167/jov.24.9.13 · Cited by 3
Hydrogels Innovation: A Review on Recent Development, Characterization and Applications
Ahirwar, V., & Jain, D. (2024) · Drug Delivery Letters · doi:10.2174/0122103031318362241015062649 · Cited by 3
Razeghinejad, R., Tajbakhsh, Z., & Nowroozzadeh, M. H. (2017) · Eye · doi:10.1038/eye.2017.103 · Cited by 3
Domínguez‐Vicent, A., & Brautaset, R. (2018) · Medical Science Monitor · doi:10.12659/msm.907683 · Cited by 3
Mustafa, M. M. S. M., Mutalib, H. A., Kaur, S., & Mk, K. (2016) · IIUM Medical Journal Malaysia · doi:10.31436/imjm.v15i1.409 · Cited by 3
Campbell, P., Edgar, D. F., & Shah, R. (2021) · Clinical and Experimental Optometry · doi:10.1080/08164622.2021.1878831 · Cited by 3
Sander, B. P. (2021) · Journal of Ocular Pharmacology and Therapeutics · doi:10.1089/jop.2021.0006 · Cited by 3
Zhou, W.-Y., Lou, Y., Pan, B., & Huang, J. (2015) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-16672 · Cited by 3
Carkeet, A. (2015) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12205 · Cited by 3
Piedrahita‐Alonso, E., López-Redondo, E., Valverde-Megías, A., Felipe-Márquez, G., Martin‐García, B., & de Liaño, R. G. (2024) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2024.08.004 · Cited by 2
Albero‐Ros, E., Lorente‐Velázquez, A., Madrid‐Costa, D., & González‐Pérez, M. (2025) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2025.102378 · Cited by 2
González‐Pérez, M., Barrio, A. R., García, R. S., Pérez‐Garmendia, C., & Antona, B. (2025) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13540 · Cited by 2
Akagün, N., & Altıparmak, U. E. (2026) · Vision · doi:10.3390/vision10020019 · Cited by 2
Evaluation of a three-axial acceleromyography monitor in dogs compared with mechanomyography
Tseng, C. T., Sakai, D. M., Lorenzutti, A. M., & Martin‐Flores, M. (2023) · Veterinary Anaesthesia and Analgesia · doi:10.1016/j.vaa.2023.06.002 · Cited by 2
Validation of a low intrusiveness heart rate sensor for stress assessment
Pereira, T., Almeida, P. R., Cunha, J. P. S., & Aguiar, A. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/3/1/017004 · Cited by 2
Quality control of test iodine in urine by spectrophotometry UV–Vis
Huda, T., Nafisah, D., Kumorowulan, S., & Lestari, S. (2017) · AIP conference proceedings · doi:10.1063/1.5016017 · Cited by 2
Makateb, A., Nabavi, A., Tabrizi, M. N., Hashemian, H., & Shirzadi, K. (2021) · Journal of Current Ophthalmology · doi:10.4103/joco.joco_56_21 · Cited by 2
Venkataraman, A. P., Al‐Soboh, L., Hedström, J., & Domínguez‐Vicent, A. (2024) · Scientific Reports · doi:10.1038/s41598-024-53293-9 · Cited by 2
Agreement studies: clarification
McAlinden, C., Khadka, J., & Pesudovs, K. (2012) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2012.00929.x · Cited by 2
Self-citationElliott, D. B. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2011.00874.x · Cited by 2
Ali, S., Byanyima, R. K., Ononge, S., Ictho, J., Nyamwiza, J., Loro, E. L. E., Mukisa, J., Musewa, A., Nalutaaya, A., Ssenyonga, R., et al. (2018) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-018-1769-2 · Cited by 2
Test‐retest Reliability of the qReading Method in Normally Sighted Young Adults
Shepard, T. G., Lu, Z., & Yu, D. (2021) · Optometry and Vision Science · doi:10.1097/opx.0000000000001754 · Cited by 2
Werner, J. U., Dreyhaupt, J., & Enders, C. (2023) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/23258160-20230707-01 · Cited by 2
Multivariate analysis of refractive state in eyes with keratoconus
Chetty, E. (2023) · BMJ Open Ophthalmology · doi:10.1136/bmjophth-2023-001344 · Cited by 2
Rohim, R. A. A., Ahmad, W. M. A. W., Ismail, N. H., Yaqoob, M. A., Alam, M. K., & Ghazali, F. M. M. (2020) · Bangladesh Journal of Medical Science · doi:10.3329/bjms.v19i3.45874 · Cited by 2
Accuracy and Precision of a Novel Photogate System to Measure Toe Clearance on Stairs
Skervin, T. K., Thomas, N. M., Schofield, A. J., Hollands, M. A., Maganaris, C. N., O’Brien, T. D., Baltzopoulos, V., & Foster, R. J. (2023) · Sensors · doi:10.3390/s23052429 · Cited by 1
Lawrenson, J. G., Gill, S., Masuid, I., & Rashid, F. (2023) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13199 · Cited by 1
Stodtmeister, R., Menzel, A., Klimová, A., Herber, R., Pillunat, L. E., & Pillunat, L. E. (2024) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-023-06326-4 · Cited by 1
Evaluating Airflow Sensor Methods: Precision in Indirect Calorimetry
Titheradge, P. J., & Robergs, R. A. (2024) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.14674 · Cited by 1
McConnell, E. L., Woods, C., Doyle, L. A., Fulton, J. M., Saunders, K. J., & McCullough, S. J. (2025) · Children · doi:10.3390/children12020121 · Cited by 1
Quantifying Grating Acuity in Children With Developmental Delays Using Newborn Acuity Cards
Sumalini, R., Ampolu, B., & Satgunam, P. (2025) · Journal of Visual Impairment & Blindness · doi:10.1177/0145482x251320107 · Cited by 1
Lei, C. S., Yang, X., Ning, R., Xiahou, J., Jiang, X., Savini, G., Schiano‐Lomoriello, D., Zhou, X., Li, K., & Huang, J. (2025) · Ophthalmology and Therapy · doi:10.1007/s40123-025-01120-3 · Cited by 1
Fulton, J. M., Leighton, R. E., Uwacu, T. D. F., MOORE, B. D., & Little, J. (2025) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13557 · Cited by 1
Exploring the do-it-yourself approach in subjective refraction
Salvador‐Roger, R., Esteve-Taboada, J. J., Ferrer-Altabás, S., Micó, V., Domínguez‐Vicent, A., & Venkataraman, A. P. (2025) · PLoS ONE · doi:10.1371/journal.pone.0334644 · Cited by 1
Muzyka−Woźniak, M., Kaminska, I., Piwowarczyk, P., & Szczęsna-Iskander, D. H. (2026) · Clinical ophthalmology · doi:10.2147/opth.s571059 · Cited by 1
Montaña, H. A. S., Cely, L. M. R., & Solarte, Y. C. D. (2016) · Ciencia y Tecnología para la Salud Visual y Ocular · doi:10.19052/sv.3838 · Cited by 1
Gupta, N., Maharjan, S., & Sapkota, S. (2023) · Nepalese Journal of Ophthalmology · doi:10.3126/nepjoph.v15i2.57044 · Cited by 1
Sossou, I. S., Oliveira, C., da Encarnação, I. G. A., Oliveira, R. R. D. M., Cerqueira, M. S., & Moreira, O. (2026) · Nutrition Clinique et Métabolisme · doi:10.1016/j.nupar.2026.103045 · Cited by 1
Chen, Y., Yang, X., Li, Z., Tan, B., Li, K., Savini, G., Schiano‐Lomoriello, D., Zhou, X. Y., Lei, C. S., & Huang, J. (2026) · Eye and Vision · doi:10.1186/s40662-026-00492-2 · Cited by 1
Álvarez, A. L., Álvarez, J. M. E., & Giraldo, A. L. (2013) · Ciencia y Tecnología para la Salud Visual y Ocular · doi:10.19052/sv.2315 · Cited by 1
Olaleye, O. A., Olatunji, O. O., Jimoh, K. O., & Olaleye, A. O. (2022) · Journal of West African College of Surgeons · doi:10.4103/jwas.jwas_165_22 · Cited by 1
Detecting True Change in Keratoconus after Intracorneal Ring Segment Implantation
Arnalich‐Montiel, F., Fuente, C., Auladell, C., & Ortiz-Toquero, S. (2023) · Life · doi:10.3390/life13040978 · Cited by 1
Reliability and Agreement of an Integrated Platform for Intelligent Visual Function Measurement
Cai, W.-J., Lin, S., Chen, R., Zhuo, R., Li, X., Yu, J., Huang, J., Chen, Z., Xu, C., & Huang, X. (2023) · Ophthalmology and Therapy · doi:10.1007/s40123-023-00718-9 · Cited by 1
Multivariate analysis of repeatability for the Near Eye Tool for Refractive Assessment (NETRA)
Hasrod, N., & RUBIN, A. M. (2023) · BMJ Open Ophthalmology · doi:10.1136/bmjophth-2023-001458 · Cited by 1
Barrio, A. R., Antona, B., Morago-Villanueva, S., Martínez-Arribas, V., & González‐Pérez, M. (2024) · Clinical and Experimental Optometry · doi:10.1080/08164622.2024.2324978 · Cited by 1
Ortiz-Toquero, S., Sánchez, I., Gurrea, C., Recio, A., Balsa, D., & Martín, R. (2024) · Life · doi:10.3390/life14030407 · Cited by 1
Mechó‐García, M., Arcas‐Carbonell, M., Orduna, E., Sánchez-Cano, A. I., & González‐Méijome, J. M. (2024) · Current Eye Research · doi:10.1080/02713683.2024.2378009 · Cited by 1
Martínez‐Alberquilla, I., Rico‐del‐Viejo, L., Venkataraman, A. P., & Domínguez‐Vicent, A. (2025) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13507 · Cited by 1
The validity and reliability of the handheld SW-100 autokeratometer
Iyamu, E., & Amiebenomo, O. M.-A. (2015) · African vision and eye health · doi:10.4102/aveh.v74i1.26 · Cited by 1
Keratoconic Bi-aspheric Contact Lenses
Gordon‐Shaag, A., Fine, P., Gantz, L., Said, A. G. A., & Serero, G. (2016) · International Journal of Keratoconus and Ectatic Corneal Diseases · doi:10.5005/jp-journals-10025-1134 · Cited by 1
Ctori, I., Mahroo, O. A., Williams, K. M., Hammond, C. J., & Huntjens, B. (2018) · Acta Ophthalmologica · doi:10.1111/aos.13725 · Cited by 1
Ferrer‐Blasco, T., Domínguez‐Vicent, A., García‐Lázaro, S., Dı́ez-Ajenjo, M. A., Alfonso, J. F., & Esteve-Taboada, J. J. (2018) · International Journal of Ophthalmology · doi:10.18240/ijo.2018.07.11 · Cited by 1
Clinical Reliability of IOL Master 700 in Measurement of Pupil Diameter and Corneal Curvature
Ryu, H. K., & Shin, S. Y. (2021) · Journal of the Korean Ophthalmological Society · doi:10.3341/jkos.2021.62.8.1022 · Cited by 1
Jung, Y.-R., Park, H.-M., & Chu, B. S. (2021) · Journal of Korean Ophthalmic Optics Society · doi:10.14479/jkoos.2021.26.4.307 · Cited by 1
Reliability and agreement of apparent chord mu measurements between static and dynamic evaluations
Plaza, E. M., Marcos, M., la Rosa, A. L., López‐Miguel, A., & Maldonado, M. J. (2022) · Journal of Cataract & Refractive Surgery · doi:10.1097/j.jcrs.0000000000001036 · Cited by 1
Design, reliability and validity of a paediatric rate of reading (PRR) chart.
Nirghin, U. (2012) · ResearchSpace (University of KwaZulu-Natal) · Cited by 1
Hiscox, R. (2013) · ORCA Online Research @Cardiff (Cardiff University) · Cited by 1
Editorial Board Changes at OPO
Elliott, D. B. (2013) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12085 · Cited by 1
The clinical skills of optometrists in assessing the anterior chamber angle
Campbell, P. (2014) · Cited by 1
Visual acuity in normal and diseased eyes using high-pass filtered optotypes
Shah, N. (2018) · UCL Discovery (University College London) · Cited by 1
Xu, Q., Wang, K., Li, Y., Qu, J., & Zhao, M. (2021) · Research Square · doi:10.21203/rs.3.rs-535008/v1 · Cited by 1
Liu, A., Xu, Z., Wang, J., Liu, F., Jiang, Y., Yang, M., Mei, L., Ge, M., Yang, Q., Huang, Y., et al. (2019) · Research Square · doi:10.21203/rs.2.508/v1 · Cited by 1
Reliability of corneal topographic analysis with anterior segment optical coherence tomography
Huang, J., Wang, Q., & Pesudovs, K. (2012) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2011.12.019
Self-citationPrecision of anterior and posterior corneal curvature measurements taken with the Oculus Pentacam
Chetty, E. (2016) · African vision and eye health · doi:10.4102/aveh.v75i1.329
Higher-order aberrations in keratoconus
Jinabhai, A. N., Donnell, C. O., Radhakrishnan, H., & Charman, W. N. (2012) · Research Explorer (The University of Manchester)
Test–retest reliability of contrast visual acuities in a clinical population
Sukha, A. Y., & RUBIN, A. M. (2017) · African vision and eye health · doi:10.4102/aveh.v76i1.376
Evaluation of computerised programs for the diagnosis and treatment of binocular anomalies
Lin, W. Y. (2016) · Research Explorer (The University of Manchester)
Spatial Characteristics of the Response of the Human Choroid to Imposed Defocus
Hoseini-Yazdi, S. H. (2018) · Queensland University of Technology · doi:10.5204/thesis.eprints.120362
Lafosse, E. (2019) · Aston Publications Explorer (Aston University) · doi:10.48780/publications.aston.ac.uk.00041160
Validation of Mahajan's formula for scaling ocular higher-order aberrations by pupil size
McKelvie, J., Wallace, H., & Misra, S. L. (2020) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_773_19
Evaluation of Reading Performance and Visual Acuity Tests
Baashen, M. (2020) · Aston Publications Explorer (Aston University) · doi:10.48780/publications.aston.ac.uk.00042451
Design and validation of a prototype to calibrate the pressure variable in tonometry
Zapata, U. F. P., & Daza-Fernández, J. F. (2021) · DYNA · doi:10.15446/dyna.v88n218.91715
Tairi, A. I., Ogbuehi, K. C., Zafar, H., King, M. D., Obinwanne, C. J., Mashige, K. P., & Osuagwu, U. L. (2022) · African vision and eye health · doi:10.4102/aveh.v81i1.691
Evidence-based eye examinations
Elliott, D. B. (2014) · Elsevier eBooks · doi:10.1016/b978-0-7020-5194-4.00001-8
Thorud, H.-M. S., Helland, M., Aarås, A., Kvikstad, T. M., Lindberg, L. G., & Horgen, G. (2014) · Optometry and Vision Science · doi:10.1097/opx.0000000000000457
Erratum for “Pyramidal Aberrometry in Wavefront-Guided Myopic LASIK”
Фрингс, А., Hassan, H., & Allan, B. (2021) · Journal of Refractive Surgery · doi:10.3928/1081597x-20210511-01
Metadata
- Authors
- McAlinden, C., Khadka, J., & Pesudovs, K.
- Affiliations
- Flinders University (AU)
- Corresponding author
- McAlinden, Colm
- Venue
- Ophthalmic and Physiological Optics
- Published
- 2011-05-26
- Volume
- 31
- Issue
- 4
- Pages
- 330-338
- ISSN
- 0275-5408 (ISSN-L)
- 1475-1313
- OpenAlex
- W2126376404
- Cited by
- 436
- References
- 49
- Citations by year
- 2026: 22 · 2025: 24 · 2024: 33 · 2023: 30 · 2022: 37 · 2021: 42 · 2020: 47 · 2019: 33 · 2018: 22 · 2017: 28 · 2016: 27 · 2015: 27 · 2014: 20 · 2013: 15 · 2012: 22
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Ophthalmic and Physiological Optics (publishedVersion)
- PubMed (publishedVersion)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
- Keywords
- repeatability, reproducibility, limits of agreement, correlation coefficient, ophthalmic instruments, sample size, measurement precision, optometry
- MeSH terms
- Humans, Ophthalmology, Optometry, Vision, Ocular, Reproducibility of Results, Qualitative Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review