Restoration of Lateral Hand Grasp Using Natural Sensors
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A closed‐loop control system for controlling the key grip of a C6tetraplegic patient was developed. Natural sensors served as the source of thefeedbacksignal. The neural signals from cutaneous receptors were picked up by animplanted cuff electrode placed around the radial branch of the median nerveinnervating the lateral partof the index finger. Mechanical stress applied to the skin, like pressure andslips, resulted in an increase in amplitude of the recorded neural signal. Thegoal of the study wasto determine whether the recorded neural signals were able to indicate the slipof an object during lateral grasp and whether the slip could be stopped byincreasing the graspforce through functional electrical stimulation of the thumb adductor andflexor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168
Self-citation
Research works printed but not linked: 4
- 10.1109/86.296345 · DOI · Paper page
- 10.1109/86.242426 · DOI · Paper page
- Sinkjær T, 1994, Natural neural sensing and artificial muscle control in man., Exp Brain Res, 21, 542
- 10.1385/0-89603-185-3:65 · DOI · Paper page
Cited by
Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227
Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168
Self-citationCuff electrodes for long-term recording of natural sensory information
Struijk, J. J., Thomsen, M., Larsen, J. O., & Sinkjaer, T. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765194 · Cited by 97
Micera, S., Jensen, W., Sepulveda, F., Riso, R. R., & Sinkjaer, T. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930903 · Cited by 58
Jensen, W., Sinkjaer, T., & Sepulveda, F. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.802851 · Cited by 26
“Closed-loop controlled functional electrical stimulation (FES) systems have demonstrated to be a useful technique to restore motor function if the peripheral nerves and muscles have remained intact [ 1 ]‐[5] below the level of lesion.”
Method
Metadata
- Authors
- Haugland, M., Lickel, A., Riso, R., Adamczyk, M. M., Keith, M., Jensen, I. L., Haase, J., & Sinkjær, T.
- Venue
- Artificial Organs
- Publisher
- Wiley
- Published
- 1997-03
- Volume
- 21
- Issue
- 3
- Pages
- 250-253
- ISSN
- 0160-564X (ISSN-L)
- 1525-1594
- OpenAlex
- W2147548785
- Cited by
- 52
- References
- 1
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Restoration of Lateral Hand Grasp Using Natural Sensors. https://app.cochat.ai/papers/10.1111/j.1525-1594.1997.tb04661.x
- The paper
- Haugland, M., Lickel, A., Riso, R., Adamczyk, M. M., Keith, M., Jensen, I. L., Haase, J., & Sinkjær, T. (1997). Restoration of Lateral Hand Grasp Using Natural Sensors. Artificial Organs. https://doi.org/10.1111/j.1525-1594.1997.tb04661.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.