Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 271

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Detergent Decellularization of Heart Valves for Tissue Engineering: Toxicological Effects of Residual Detergents on Human Endothelial Cells

Cebotari, Serghei, Tudorache, Igor, Jaekel, Thomas, Hilfiker, Andres, Dorfman, Suzanne, Ternes, Waldemar, Haverich, Axel, Lichtenberg, Artur · 2010 · Artificial Organs

Abstract

Detergents are powerful agents for tissue decellularization. Despite this, the high toxicity of detergent residua can be a major limitation. This study evaluated the efficacy of detergent removal from decellularized pulmonary valves (PVs) and the consequences of repopulation with human endothelial cells (HECs). Porcine PVs were treated with 1% sodium deoxycholate (SDC), group A; 1% sodium dodecyl sulfate (SDS), group B; and a mixture of 0.5% SDC/0.5% SDS, group C (n = 5 each). After each of 10 succeeding wash cycles (WCs), samples of the washing solution (WS) were analyzed by solid phase extraction and high performance liquid chromatography for the presence of detergents. Metabolic activity of HEC was also assessed in the WS samples (cytotoxicity and MTS assays). Decellularized and washed PVs were reseeded with HEC. Histological analysis demonstrated efficient tissue decellularization in all groups. Detergents' concentration in all WSs decreased exponentially and was below 50 mg/L after 6, 8, and 4 WCs in groups A, B, and C, respectively. This concentration resulted in no significant toxic influence on cell cultures, and scaffolds could be efficiently reseeded with HEC. In conclusion, intensive washing of detergent decellularized valvular scaffolds lowers the residual contamination below a hazardous threshold and allows their successful repopulation with HEC for tissue engineering purposes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1525-1594.2009.00796.x

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 271

Metadata

Authors
Cebotari, S., Tudorache, I., Jaekel, T., Hilfiker, A., Dorfman, S., Ternes, W., Haverich, A., & Lichtenberg, A.
Venue
Artificial Organs
Publisher
Wiley
Published
2010-03
Volume
34
Issue
3
Pages
206-210
ISSN
  • 0160-564X (ISSN-L)
  • 1525-1594
OpenAlex
W2115296454
Cited by
271
References
7
FWCI
7.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detergent Decellularization of Heart Valves for Tissue Engineering: Toxicological Effects of Residual Detergents on Human Endothelial Cells. https://app.cochat.ai/papers/10.1111/j.1525-1594.2009.00796.x
The paper
Cebotari, S., Tudorache, I., Jaekel, T., Hilfiker, A., Dorfman, S., Ternes, W., Haverich, A., & Lichtenberg, A. (2010). Detergent Decellularization of Heart Valves for Tissue Engineering: Toxicological Effects of Residual Detergents on Human Endothelial Cells. Artificial Organs. https://doi.org/10.1111/j.1525-1594.2009.00796.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.