Study of Flow-Induced Hemolysis Using Novel Couette-Type Blood-Shearing Devices: THOUGHTS AND PROGRESS
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
To assist the development and application of blood-contacting medical devices, two novel flow-through Couette-type blood-shearing devices have been developed to study the quantitative relationship between blood damage indexes and flow-dependent parameters. One device is an axial flow-through Couette-type device supported by a pair of pin bearings adapted from the adult Jarvik 2000 blood pump. The other is a centrifugal flow-through Couette-type device supported with magnetic bearings adapted from the CentriMag blood pump. In both devices, a rotor spindle was used to replace the original impeller blades so that a small gap was created between the housing and the rotating spindle surface. Computational fluid dynamics simulations have shown that a uniform, high shear stress region can be generated inside the small gap while the shear stresses elsewhere are relatively low. The possibility of secondary blood damage caused by mechanical seals was eliminated due to the use of a magnetic rotor system. Blood flow through the gap was driven by an externally pressurized reservoir. By adjusting the rotational speed and blood flow rate, shear-induced hemolysis was quantified at a matrix of exposure time (0.039 to 1.48 s) and shear stress (50 to 320 Pa). All of the experiments were conducted at room temperature using heparinized ovine blood with a hematocrit value of 30%. The measured hemolysis levels were much lower than those published in the literature, and the overestimation of those earlier studies may be attributable to device-related secondary blood-damaging effects. A new set of coefficients for the power law model was derived from the regression of the experimental data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
VIII. Stability of a viscous liquid contained between two rotating cylinders
Taylor, G. I. (1923) · Philosophical Transactions of the Royal Society of London. Series A, Containing Papers of a Mathematical or Physical Character · doi:10.1098/rsta.1923.0008 · Cited by 2,502
Giersiepen, M., Wurzinger, L. J., Opitz, R., & Reul, H. (1990) · The International Journal of Artificial Organs · doi:10.1177/039139889001300507 · Cited by 594
Computational Fluid Dynamics Prediction of Blood Damage in a Centrifugal Pump
Song, X., Throckmorton, A. L., Wood, H. G., Antaki, J. F., & Olsen, D. B. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.00026.x · Cited by 160
Malinauskas, R. A. (1997) · Artificial Organs · doi:10.1111/j.1525-1594.1997.tb00486.x · Cited by 138
Tan, M., Fang, H., Tian, G., & Houghton, P. J. (2003) · Statistics in Medicine · doi:10.1002/sim.1467 · Cited by 59
Self-citationFreshwater, I. J., Morsi, Y., & LAI, T. C. (2006) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim126 · Cited by 51
Cited by
Fraser, K. H., Zhang, T., Taskin, M. E., Griffith, B. P., & Wu, Z. J. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4007092 · Cited by 384
Self-citationMorrison, T. M., Hariharan, P., Funkhouser, C. M., Afshari, P., Goodin, M., & Horner, M. (2019) · ASAIO Journal · doi:10.1097/mat.0000000000000996 · Cited by 68
Metadata
- Authors
- Zhang, T., Taskin, M. E., Fang, H.-B., Pampori, A., Jarvik, R., Griffith, B. P., & Wu, Z. J.
- Venue
- Artificial Organs
- Publisher
- Wiley
- Published
- 2011-08-02
- Volume
- 35
- Issue
- 12
- Pages
- 1180-1186
- ISSN
- 0160-564X (ISSN-L)
- OpenAlex
- W1739365082
- Cited by
- 192
- References
- 6
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.