EEG Source Imaging in Pediatric Epilepsy Surgery: A New Perspective in Presurgical Workup
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Summary: Purpose: Epilepsy is a relatively frequent disease in children, with considerable impact on cognitive and social life. Successful epilepsy surgery depends on unambiguous focus identification and requires a comprehensive presurgical workup, including several neuroimaging techniques [magnetic resonance imaging, positron emission tomography (PET), and single‐photon emission computed tomography (SPECT)]. These may be difficult to apply in younger or developmentally delayed children or both, requiring sedation, and hence, a significant workforce. Modern electric source imaging (ESI) provides accurate epileptic source‐localization information in most patients, with minimal patient discomfort or need for cooperation. The purpose of the present study was to determine the usefulness of ESI in pediatric EEG recordings performed with routine electrode arrays. Methods: Preoperative EEGs recorded from 19 to 29 scalp electrodes were reviewed, and interictal epileptiform activity was analyzed by using a linear source‐imaging procedure (depth‐weighted minimum norm) in combination with statistical parametric mapping. Results: In 27 (90%) of 30 patients, the ESI correctly localized the epileptogenic region. These numbers compare favorably with the results from other imaging techniques in the same patients (PET, 82%; ictal SPECT, 70%). In extratemporal epilepsy, ESI was correct in all cases, and in temporal lobe epilepsy, in 10 of 13 cases. In two temporal lobe patients showing less‐accurate ESI results, 128‐electrode data could be analyzed, and in both cases, the 128‐electrode ESI was correct. Conclusions: ESI with standard clinical EEG recordings provides excellent localizing information in pediatric patients, in particular in extratemporal lobe epilepsy. The lower yield in temporal lobe epilepsy seems to be due to undersampling of basal temporal areas with routine scalp recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spherical splines for scalp potential and current density mapping
Perrin, F., Pernier, J., Bertrand, O., & Echallier, J. F. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90180-6 · Cited by 2,706 · cited 1×
“To identify electrodes with artifacts, the surface voltage map was checked for several time points during the spike–wave complex, and electrodes in which the map distribution revealed artifacts were interpolated by using a 3D-spline interpolation algorithm (50).”
MethodEpileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413
Self-citationEEG dipole modeling in complex partial epilepsy
Ebersole, J. S. (1991) · Brain Topography · doi:10.1007/bf01132768 · Cited by 132
Cited by
Towards the utilization of EEG as a brain imaging tool
Michel, C. M., & Murray, M. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.039 · Cited by 738
Self-citationEEG Source Imaging: A Practical Review of the Analysis Steps
Michel, C. M., & Brunet, D. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00325 · Cited by 705
Self-citationHigh-frequency oscillations (HFOs) in clinical epilepsy
Jacobs, J., Staba, R., Asano, E., Otsubo, H., Wu, J. Y., Zijlmans, M., Mohamed, I., Kahane, P., Dubeau, F., Navarro, V., et al. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.03.001 · Cited by 443
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
“It remains to be shown in future studies using simultaneous intracranial EEG if mesial temporal interictal epileptiform discharges could be localized non-invasively with high-density EEG/MEG or with combined EEG–functional MRI (Sperli et al., 2006; Kaiboriboon et al., 2010; Vulliemoz et al., 2010; Grouiller et al., 20…”
BackgroundInfluentialSelf-citationLerner, J. T., Salamon, N., Hauptman, J. S., Velasco, T. R., Hemb, M., Wu, J. Y., Sankar, R., Donald Shields, W., Engel Jr, J., Fried, I., et al. (2009) · Epilepsia · doi:10.1111/j.1528-1167.2008.01998.x · Cited by 390
Metadata
- Authors
- Sperli, F., Spinelli, L., Seeck, M., Kurian, M., Michel, C. M., & Lantz, G.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2006-06
- Volume
- 47
- Issue
- 6
- Pages
- 981-990
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2019037321
- Cited by
- 137
- References
- 3
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EEG Source Imaging in Pediatric Epilepsy Surgery: A New Perspective in Presurgical Workup. https://app.cochat.ai/papers/10.1111/j.1528-1167.2006.00550.x
- The paper
- Sperli, F., Spinelli, L., Seeck, M., Kurian, M., Michel, C. M., & Lantz, G. (2006). EEG Source Imaging in Pediatric Epilepsy Surgery: A New Perspective in Presurgical Workup. Epilepsia. https://doi.org/10.1111/j.1528-1167.2006.00550.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.