Field and Laboratory Alcohol Detection With 2 Types of Transdermal Devices
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: Two types of transdermal electrochemical sensors that detect alcohol at the skin surface were evaluated. One, the AMS SCRAM™ device, is locked onto the ankle and is based on a fuel cell sensor; the other, a Giner WrisTAS™ device, worn on the wrist, is based on a proton exchange membrane. SCRAM is used by several court systems in the United States to monitor alcohol offenders, WrisTAS, a research prototype, is not commercially available. Methods: The 2 devices were worn concurrently by 22 paid research subjects (15 men, 7 women), for a combined total of 96 weeks. Subjects participated in both laboratory‐dosed drinking to a target of 0.08 g/dl blood alcohol concentration (BAC), and normal drinking on their own; all subjects were trained to use and carry a portable fuel‐cell breath tester for BAC determinations. Overall 271 drinking episodes with BAC ≥ 0.02 g/dl formed the signal for detection—60 from laboratory dosing, and 211 from self‐dosed drinking, with BAC ranging from 0.02 to 0.230 g/dl (mean 0.077 g/dl). Results: False negatives were defined as a transdermal alcohol concentration response equivalent <0.02 g/dl when BAC ≥ 0.02 g/dl. The overall true‐positive hit rate detected by WrisTAS was 24%. The low detection rate was due to erratic output and not recording during nearly 67% of all episodes; reportedly a chipset, not a sensor problem. SCRAM correctly detected 57% across all BAC events, with another 22% (total 79%) detected, but as <0.02 g/dl. When subjects dosed themselves to BAC ≥ 0.08 g/dl, SCRAM correctly detected 88% of these events. SCRAM devices lost accuracy over time likely due to water accumulation in the sensor housing. Neither unit had false‐positive problems when true BAC was <0.02 g/dl. Conclusions: Each device had peculiarities that reduced performance, but both types are able to detect alcohol at the skin surface. With product improvements, transdermal sensing may become a valuable way to monitor the alcohol consumption of those who should be abstaining.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Studies on a Wearable, Electronic, Transdermal Alcohol Sensor
Swift, R. M., Martin, C. S., Swette, L., LaConti, A., & Kackley, N. (1992) · Alcoholism: Clinical and Experimental Research · doi:10.1111/j.1530-0277.1992.tb00668.x · Cited by 114 · cited 1×
“Swift and colleagues (Swift, 2003; Swift et al., 1992) published evidence over a 10-year span that demonstrated the accuracy of the Giner sensor.”
BackgroundTransdermal Alcohol Measurement for Estimation of Blood Alcohol Concentration
Swift, R. (2000) · Alcoholism: Clinical and Experimental Research · doi:10.1111/j.1530-0277.2000.tb02006.x · Cited by 101 · cited 2×
“Swift and colleagues (1992) and Swift (2000) reported that the WrisTAS linearity extends from 5 to 500 mg ⁄dl (0.005 to 0.50 g ⁄dl).”
BackgroundInfluential
Cited by
Prospects and Challenges of Volatile Organic Compound Sensors in Human Healthcare
Jalal, A. H., Alam, F., Roychoudhury, S., Umasankar, Y., Pala, N., & Bhansali, S. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00400 · Cited by 315
Simons, J. S., Wills, T. A., Emery, N. N., & Marks, R. M. (2015) · Addictive Behaviors · doi:10.1016/j.addbeh.2015.06.042 · Cited by 239
“These devices are commonly used in the criminal justice system to monitor enforced abstinence (Marques & Mcknight, 2009).”
BackgroundLeffingwell, T. R., Cooney, N. J., Murphy, J. G., Luczak, S., Rosen, G., Dougherty, D. M., & Barnett, N. P. (2013) · Alcoholism: Clinical and Experimental Research · doi:10.1111/j.1530-0277.2012.01869.x · Cited by 142
“In a recent report, Marques and McKnight (2009) evaluated both the SCRAM and the WrisTAS in laboratory and field conditions.”
InfluentialWearable electrochemical alcohol biosensors
Campbell, A. S., Kim, J., & Wang, J. (2018) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2018.05.014 · Cited by 140
Metadata
- Authors
- Marques, P. R., & McKnight, A. S.
- Venue
- Alcoholism: Clinical and Experimental Research
- Publisher
- Wiley
- Published
- 2009-03-25
- Volume
- 33
- Issue
- 4
- Pages
- 703-711
- ISSN
- 0145-6008 (ISSN-L)
- 1530-0277
- OpenAlex
- W2158926281
- Cited by
- 103
- References
- 3
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).