CoChat

BLOOD DONORS AND BLOOD COLLECTION: Delayed adverse reactions to blood donation

Kamel, Hany, Tomasulo, Peter, Bravo, Marjorie, Wiltbank, Thomas, Cusick, Robin, James, Robert C., Custer, Brian · 2010 · Transfusion
Cited by 106

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Blood donation is safe, but a small proportion of donors have delayed and/or off‐site reactions that have the potential to lead to serious injury. This retrospective study sought to identify risk factors for delayed reactions (DRs). STUDY DESIGN AND METHODS: The records of 793,293 allogeneic whole blood and apheresis donations in 2007 were assessed for vasovagal reactions. Donor demographic, biometric, and clinical measurements were captured. Incidents related to needle insertion and mild reactions were excluded. Based on the reaction onset time relative to the procedure end time, reactions were classified as delayed (>15 min) or immediate (≤15 min). Reactions were analyzed by multivariable logistic regression comparing donors with immediate reactions (IRs) or DRs to donors without reactions and comparing donors with DRs to IRs. The clinical consequences of off‐site and on‐site reactions are reported. RESULTS: The prevalence of reactions classified as moderate or severe was 41 in 10,000 donations; 24% of these reactions were delayed and 12% occurred off‐site. DRs were associated with female sex (odds ratio [OR], 2.96; 95% confidence interval [CI], 2.21‐3.96) and with low estimated blood volume (EBV; OR, 3.91; 96% CI, 2.84‐5.51). Off‐site reactions, particularly in female donors, were more likely to be associated with a fall, with head trauma, with other injury, and with the use of outside medical care. CONCLUSION: Low EBV, youth, and first‐time donor status are major risk factors for IRs and DRs. Women are more likely than men to report DRs. Delayed and off‐site reactions lead to potentially preventable morbidity. Understanding the physiologic basis of DRs may lead to the development of appropriate interventions to reduce their likelihood.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1537-2995.2009.02397.x

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 106

Metadata

Authors
Kamel, H., Tomasulo, P., Bravo, M., Wiltbank, T., Cusick, R., James, R. C., & Custer, B.
Venue
Transfusion
Publisher
Wiley
Published
2010-03
Volume
50
Issue
3
Pages
556-565
ISSN
  • 0041-1132 (ISSN-L)
  • 1537-2995
OpenAlex
W1773473976
Cited by
106
References
13
FWCI
20.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.