Clinical measurement of thrombin generation by calibrated automated thrombography requires contact factor inhibition
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibrated Automated Thrombin Generation Measurement in Clotting Plasma
Hemker, H. C., Giesen, P., Al Dieri, R., Regnault, V., de Smedt, E., Wagenvoord, R., Lecompte, T., & Béguin, S. (2003) · Pathophysiology of Haemostasis and Thrombosis · doi:10.1159/000071636 · Cited by 1,430
Osterud, B., & Rapaport, S. I. (1977) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.74.12.5260 · Cited by 787
Factor XI Activation in a Revised Model of Blood Coagulation
Gailani, D., & Broze, G. J. (1991) · Science · doi:10.1126/science.1652157 · Cited by 775
What is all that thrombin for?
Mann, K. G., Brummel, K., & Butenas, S. (2003) · Journal of Thrombosis and Haemostasis · doi:10.1046/j.1538-7836.2003.00298.x · Cited by 560
Blood clotting in minimally altered whole blood
Rand, M., Lock, J., van't Veer, C., Gaffney, D., & Mann, K. (1996) · Blood · doi:10.1182/blood.v88.9.3432.bloodjournal8893432 · Cited by 400
Thrombin functions during tissue factor–induced blood coagulation
Brummel, K. E., Paradis, S. G., Butenas, S., & Mann, K. G. (2002) · Blood · doi:10.1182/blood.v100.1.148 · Cited by 397
Thrombin Generation in Plasma: Its Assessment Via the Endogenous Thrombin Potential
Hemker, H. C., & Béguin, S. (1995) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1642666 · Cited by 290
The Thrombogram: Monitoring Thrombin Generation in Platelet Rich Plasma
Giesen, P., Ramjee, M., Wagenvoord, R., Béguin, S., & Hemker, C. (2000) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1613868 · Cited by 287
Hemker, H. C., Willems, G. M., & Béguin, S. (1986) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1661594 · Cited by 254
Autoactivation of human Hageman factor. Demonstration utilizing a synthetic substrate.
Silverberg, M., Dunn, J. T., Garen, L., & Kaplan, A. P. (1980) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(20)79699-7 · Cited by 226
Phenotyping the Clotting System
Beguín, S., & Hemker, H. C. (2000) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1614109 · Cited by 181
Hageman factor fragment inhibitor in corn seeds: Purification and characterization
Hojima, Y., Pierce, J. V., & Pisano, J. J. (1980) · Thrombosis Research · doi:10.1016/0049-3848(80)90381-3 · Cited by 180
Kumar, R., Beguín, S., & Hemker, H. C. (1994) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1648947 · Cited by 142
Differential Effects of Anticoagulants on the Activation of Platelets Ex Vivo
Schneider, D. J., Tracy, P. B., Mann, K. G., & Sobel, B. E. (1997) · Circulation · doi:10.1161/01.cir.96.9.2877 · Cited by 122
Contact between a polymer and whole blood: Sequence of events leading to thrombin generation
Hong, J., Larsson, A., Nilsson‐Ekdahl, K., Elgue, G., Larsson, R., & Nilsson, B. (2001) · Journal of Laboratory and Clinical Medicine · doi:10.1067/mlc.2001.116486 · Cited by 59
Cited by
Sarin, S. K., Kedarisetty, C. K., Abbas, Z., Amarapurkar, D., Bihari, C., Chan, A. C. Y., Chawla, Y. K., Dokmeci, A. K., Garg, H., Ghazinyan, H., et al. (2014) · Hepatology International · doi:10.1007/s12072-014-9580-2 · Cited by 1,481
“Thrombin generation assay (TGA) by Calibrated automated thrombogram (CAT) is being increasingly recognized as a versatile tool to investigate the patients with hypo or hypercogulable phenotypes in liver diseases [64, 65].”
Methodological Guidelines to Study Extracellular Vesicles
Coumans, F. A. W., Brisson, A. R., Buzas, E. I., Dignat-George, F., Drees, E. E. E., El-Andaloussi, S., Emanueli, C., Gasecka, A., Hendrix, A., Hill, A. F., et al. (2017) · Circulation Research · doi:10.1161/circresaha.117.309417 · Cited by 1,017
Semeraro, F., Ammollo, C. T., Morrissey, J. H., Dale, G. L., Friese, P., Esmon, N. L., & Esmon, C. T. (2011) · Blood · doi:10.1182/blood-2011-03-343061 · Cited by 867
Thrombelastography/thromboelastometry
LUDDINGTON, R. J. (2005) · Clinical and Laboratory Haematology · doi:10.1111/j.1365-2257.2005.00681.x · Cited by 655
Self-citationAptamer binding assays for proteins: The thrombin example—A review
Deng, B., Lin, Y., Wang, C., Li, F., Wang, Z., Zhang, H., Li, X.-F., & Le, X. C. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.04.055 · Cited by 379
Metadata
- Authors
- Luddington, R., & Baglin, T.
- Venue
- Journal of Thrombosis and Haemostasis
- Publisher
- Elsevier BV
- Published
- 2004-11
- Volume
- 2
- Issue
- 11
- Pages
- 1954-1959
- ISSN
- 1538-7836 (ISSN-L)
- OpenAlex
- W1977689290
- Cited by
- 190
- References
- 15
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.