CoChat

The Etiology of Syncope in Pacemaker Patients

PAVLOVIC, SINISA U., KOCOVIC, DUSAN, DJORDJEVIC, MILAN, BELKIC, KAREN, KOSTIC, DUSAN, VELIMIROVIC, DUSAN · 1991 · Pacing and Clinical Electrophysiology
Cited by 48

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

A total of 46 patients with syncopal episodes after VVI pacemaker implantation were studied. Of these, 92% had one to three syncopal episodes and 8% more than three. All underwent a thorough clinical examination, which included chest X ray, echocardiogram, neurological exam, and the following protocol: 24‐hour Holler monitoring, EEG, blood pressure (BP) measurement in three positions, Doppler exam of the carotid vessels, fasting blood glucose, and head‐up tilt table test (60 minutes, 60°). Holter monitoring showed exit block in two patients (4.3%) and failed sensing in one (2.1%). In two patients there was unilateral slowing on EEG. Orthostatic hypotension was found in four patients (8.6%), and hypoglycemia in three insulin‐dependent diabetics. An ocdusive atherosclerotic plaque in the carotid artery was found in three patients (6,5%). Syncope was induced in 17 patients (36,9%) by the tilt table test, after a mean standing time of 47 ± 11 minutes. The mean resting systolic BP of these patients was 140 ± 24 mmHg, and fell to a mean level of 56 ± 8 mmHg (mean systolic BP drop was 79 ± 8 mmHg). Sixteen of these 17 patients with positive tilt table were being paced at the time of syncope and one had a spontaneous heart rate of 73 beats/min. In 14 cases (30.4%) the cause of syncopai episodes after this extensive workup remained unexplained. These results indicate that pacemaker dysfunction is a not major cause of syncopal episodes in pacemaker patients and that these are most often due to vasovagal syncope. Long‐term follow‐up is warranted to determine the prognostic significance of various types of syncope in pacemaker patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1991.tb06478.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 48

Metadata

Authors
PAVLOVIC, S. U., KOCOVIC, D., DJORDJEVIC, M., BELKIC, K., KOSTIC, D., & VELIMIROVIC, D.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1991-12
Volume
14
Issue
12
Pages
2086-2091
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2045903949
Cited by
48
References
3
FWCI
1.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Etiology of Syncope in Pacemaker Patients. https://app.cochat.ai/papers/10.1111/j.1540-8159.1991.tb06478.x
The paper
PAVLOVIC, S. U., KOCOVIC, D., DJORDJEVIC, M., BELKIC, K., KOSTIC, D., & VELIMIROVIC, D. (1991). The Etiology of Syncope in Pacemaker Patients. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1991.tb06478.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.