Clinical Experience with Thera DR Rate‐Drop Response Pacing Algorithm in Carotid Sinus Syndrome and Vasovagal Syncope
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This study examined the effectiveness of cardiac pacing using the Thera DR rate‐drop response algorithm for prevention of recurrent symptoms in patients with carotid sinus syndrome (CSS) or vasovagal syncope. The algorithm comprises both diagnostic and treatment elements. The diagnostic element consists of a programmable “window” used to identify heart rate changes compatible with an evolving neurally mediated syncopal episode. The treatment arm consists of pacing at a selectable rate and for a programmable duration. Forty‐three patients (mean age 53 ± 20.4 years) with CSS alone (n = 8), CSS in conjunction with vasovagal syncope (n = 4), or vasovagal syncope alone (n = 31) were included. Thirty‐nine had recurrent syncope, while the remaining four reported multiple presyncopal events. Prior to pacing, 40 ± 152 syncopal episodes (range from 1 to approximately 1,000 syncopal events) over the preceding 56 ± 84.5 months. Postpacing follow‐up duration was 204 ± 172 days. Three patients have been lost to follow‐up and in one patient the algorithm was disabled. Among the remaining 39 individuals, 31 (80%) indicated absence or diminished frequency of symptoms, or less severe symptoms. Twenty‐three patients (23/29, or 59%) were asymptomatic with respect to syncope or presyncope. Sixteen patients had symptom recurrences. Of these, seven experienced syncope (7/39, or 18%) and 9 (29%) had presyncope: the majority of patients with recurrences (6/7 syncope and 7/9 presyncope) were individuals with a history of vasovagal syncope. Consequently, although symptoms were observed during postpacing follow‐up, they appeared to be of reduced frequency and severity. Thus, our findings suggest that a transient period of high rate pacing triggered by the Thera DR rate‐drop response algorithm was beneficial in a large proportion of highly symptomatic patients with CSS or vasovagal syncope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neurogenic orthostatic hypotension: a double-blind, placebo-controlled study with midodrine
Jankovic, J., Gilden, J. L., Hiner, B. C., Kaufmann, H., Brown, D. C., Coghlan, C. H., Rubin, M., & Fouad-Tarazi, F. M. (1993) · The American Journal of Medicine · doi:10.1016/0002-9343(93)90230-m · Cited by 396
Carotid sinus hypersensitivity: beneficial effects of dual-chamber pacing
Madigan, N. P., Flaker, G. C., Curtis, J. J., Reid, J., Mueller, K. J., & Murphy, T. J. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90632-5 · Cited by 95
Is DDD superior to VVI pacing in mixed carotid sinus syndrome? An acute and medium-term study
BRIGNOLE, M., SARTORE, B., BARRA, M., MENOZZI, C., & LOLLI, G. (1988) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1988.tb06327.x · Cited by 59
Cited by
The North American vasovagal pacemaker study (VPS)
Connolly, S., Sheldon, R., Roberts, R., & Gent, M. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00549-x · Cited by 474
Sutton, R., Brignole, M., Menozzi, C., Raviele, A., Alboni, P., Giani, P., & Moya, A. (2000) · Circulation · doi:10.1161/01.cir.102.3.294 · Cited by 407
“Ospedale S. Maria Nuova, Reggio Emilia: Lolli Gino (8); Ospedali Riuniti, Lavagna: Oddone Daniele (4); Ospedale Civile, Imperia: Musso Giacomo (3); Ospedale Civile Ferrari, Casarano: Pettinati Giacinto (3); Ospedale S. Andrea, Vercelli: Gronda Maurizio (2); Ospedale S. Agostino, Modena: Moracchini Pier Vittorio, Giuli…”
BackgroundInfluentialSelf-citationPachon M, J. C., Pachon M, E. I., Pachon M, J. C., Lobo, T. J., Pachon, M. Z., Vargas, R. N. A., & Jatene, A. D. (2005) · EP Europace · doi:10.1016/j.eupc.2004.10.003 · Cited by 350
Ammirati, F., Colivicchi, F., & Santini, M. (2001) · Circulation · doi:10.1161/hc2601.091708 · Cited by 299
“Appendix Study Investigators The Syncope Diagnosis and Treatment (SYDIT) Study Investigators were as follows (the number of randomized patients is given in parentheses): D. Cornacchia, Ospedale degli Infermi, Faenza (2); G. Pulitanò, Policlinico Madonna della Consolazione, Reggio Calabria (6); M. Del Greco, Ospedale S…”
The Evaluation and Management of Bradycardia
Mangrum, J. M., & DiMarco, J. P. (2000) · New England Journal of Medicine · doi:10.1056/nejm200003093421006 · Cited by 279
Metadata
- Authors
- BENDITT, D. G., SUTTON, R., GAMMAGE, M. D., MARKOWITZ, T., GORSKI, J., NYGAARD, G. A., FETTER, J., & THE INTERNATIONAL RATE‐DROP INVESTIGATORS GROUP
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1997-03
- Volume
- 20
- Issue
- 3
- Pages
- 832-839
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2125040692
- Cited by
- 104
- References
- 3
- FWCI
- 9.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Experience with Thera DR Rate‐Drop Response Pacing Algorithm in Carotid Sinus Syndrome and Vasovagal Syncope. https://app.cochat.ai/papers/10.1111/j.1540-8159.1997.tb03916.x
- The paper
- BENDITT, D. G., SUTTON, R., GAMMAGE, M. D., MARKOWITZ, T., GORSKI, J., NYGAARD, G. A., FETTER, J., & THE INTERNATIONAL RATE‐DROP INVESTIGATORS GROUP. (1997). Clinical Experience with Thera DR Rate‐Drop Response Pacing Algorithm in Carotid Sinus Syndrome and Vasovagal Syncope. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1997.tb03916.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.