Hemodynamic Deterioration Following Radiofrequency Ablation of the Atrioventricular Conduction System
The DOI matches its Crossref record.
Abstract
Radiofrequeucy ablation of the atrioventricular conduction system (ACS) has become an estoblished theTapy for patients with drug refroctory atrial fibrillation. We observed eight patients with hemodynamic deterioration ofteT radiofrequency oblotion of the otTioventTicular conduction system. As we found hemodynamic deterioration related to worsening mitral regurgitation, we compared the clinical history, eiectrophysiologicai, ond echocardiographic dato from the patients with hemodynamic deteriorotion and worsening mitral regurgitation (group 1) to those without hemodynamic deterioration and stable mitral regurgitation after the procedure (group 2). Eight out of 108 patients (7.4%) undergoing ablation of the ACS deteriorated hemodynamically with acute pulmonary edema in three and congestive heart failure in five patients occurring at a mean of 3 and 8 weeks, respectively, after the procedure. Three of these patients were referred for mitral valve surgery. Two patients underwent ablation using a left‐sided approach. A right‐sided approach was used in five patients. In one patient, a left‐ and right‐sided approach was used. Compared to group 2 patients, group 1 patients had significantly higher left ventricular end‐diastolic diameters (64 ± 6 mm vs 56 ± 9 mm) at baseline despite similar fractional shortening (32%± Il% vs 34%± 13%), left ventricular end‐systolic diameters (43 ± 9 mm vs36 ± 7 mm) and degree of mitral regurgitation (1.4 ± 1.1 vs 1.4 ±0.7) on echocardiographic analysis. Thus, hemodynamic deterioration together with progression of mitral regurgitation is a potential complication of ablation of the ACS (up to 7.4%). Patients with high left ventricular end‐diastolic diameters ond moderate mitral regurgitation at baseline seem prone to this complication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Writing Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
Sweeney, M. O., Hellkamp, A. S., Ellenbogen, K. A., Greenspon, A. J., Freedman, R. A., Lee, K. L., & Lamas, G. A. (2003) · Circulation · doi:10.1161/01.cir.0000072769.17295.b1 · Cited by 1,773
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Deshmukh, P., Casavant, D. A., Romanyshyn, M., & Anderson, K. (2000) · Circulation · doi:10.1161/01.cir.101.8.869 · Cited by 770
Tracy, C. M., Epstein, A. E., Darbar, D., DiMarco, J. P., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P. E., Link, M. S., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 732
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.014 · Cited by 552
Biventricular Pacing in Patients with Bradycardia and Normal Ejection Fraction
Yu, C.-M., Chan, J. Y.-S., Zhang, Q., Omar, R., Yip, G. W.-K., Hussin, A., Fang, F., Lam, K. H., Chan, H. C.-K., & Fung, J. W.-H. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0907555 · Cited by 477
Vijayaraman, P., Chung, M. K., Dandamudi, G., Upadhyay, G. A., Krishnan, K., Crossley, G., Bova Campbell, K., Lee, B. K., Refaat, M. M., Saksena, S., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.06.017 · Cited by 350
“LVEF remained unchanged in the HBP group (55 8% vs. 57 6%; p ¼ 0.13), whereas a significant decline was noted in RVP (57 7% vs. 52 11%; p ¼ 0.002).”
InfluentialBrignole, M., Menozzi, C., Gianfranchi, L., Musso, G., Mureddu, R., Bottoni, N., & Lolli, G. (1998) · Circulation · doi:10.1161/01.cir.98.10.953 · Cited by 329
Heart Failure During Cardiac Pacing
Sweeney, M. O., & Hellkamp, A. S. (2006) · Circulation · doi:10.1161/circulationaha.105.608356 · Cited by 252
Direct His‐Bundle Pacing: Present and Future
DESHMUKH, P. M., & ROMANYSHYN, M. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00548.x · Cited by 183
Atrioventricular node ablation and His bundle pacing
Vijayaraman, P., Subzposh, F. A., & Naperkowski, A. (2017) · EP Europace · doi:10.1093/europace/eux263 · Cited by 161
Metadata
- Authors
- VANDERHEYDEN, M., COETHALS, M., ANCUERA, I., NELLENS, P., ANDRIES, E., BRUGADA, J., & BRUGADA, P.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1997-10
- Volume
- 20
- Issue
- 10
- Pages
- 2422-2428
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2070504657
- Cited by
- 91
- References
- 0
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.