Magnetocardiographic QT Interval Dispersion in Postmyocardial Infarction Patients with Sustained Ventricular Tachycardia: Validation of Automated QT Measurements
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
T dispersion is a measure of heterogeneity in ventricular repolarization. Increased ECG QT dispersion is associated with life‐threatening ventricular arrhythmias. We studied if magnetocardiographic (MCG) measures of QT dispersion can separate postmyocardial infarction patients with and without susceptibility to sustained VT. Manual dispersion measurements were compared to a newly adapted automatic QT interval analysis method. Ten patients with a history of sustained VT (VT group) and eight patients without ventricular arrhythmias (Controls) were studied after a remote myocardial infarction. Single‐channel MCGs were recorded from 42 locations over the frontal chest area and the signals were averaged. QT dispersion was defined as maximum — minimum or standard deviation of measured QT intervals. VT group showed significantly more QT and JT dispersion than Controls. QT apex dispersions were 127 ± 26 versus 83 ± 21 ms (P = 0.004) and QT end dispersions 130 ± 37 versus 82 ± 37 ms (P = 0.013), respectively. Automatic method gave comparable values. Their relative differences were 9% for QT apex and 27% for QT end dispersion on average. In conclusion, increased MCG QT interval dispersion seems to be associated with a susceptibility to VT in postmyocardial infarction patients. MCG mapping with automated QT interval analysis may provide a user independent method to detect nonhomogeneity in ventricular repolarization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lant, J., Stroink, G., ten Voorde, B., Horacek, B. M., & Montague, T. J. (1990) · Journal of Electrocardiology · doi:10.1016/0022-0736(90)90121-h · Cited by 63
Cited by
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
Kwong, J. S. W., Leithäuser, B., Park, J.-W., & Yu, C.-M. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.12.056 · Cited by 103
Anttonen, O., Väänänen, H., Junttila, J., Huikuri, H. V., & Viitasalo, M. (2008) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2008.00234.x · Cited by 50
Self-citationBrisinda, D., Fenici, R., & Smars, P. (2022) · Contemporary Cardiology · doi:10.1007/978-3-031-05520-1_17 · Cited by 6
Metadata
- Authors
- OIKARINEN, L., PAAVOLA, M., MONTONEN, J., VIITASALO, M., MÄKIJÄRVI, M., TOIVONEN, L., & KATILA, T.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1998-10
- Volume
- 21
- Issue
- 10
- Pages
- 1934-1942
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2039204722
- Cited by
- 65
- References
- 1
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetocardiographic QT Interval Dispersion in Postmyocardial Infarction Patients with Sustained Ventricular Tachycardia: Validation of Automated QT Measurements. https://app.cochat.ai/papers/10.1111/j.1540-8159.1998.tb00013.x
- The paper
- OIKARINEN, L., PAAVOLA, M., MONTONEN, J., VIITASALO, M., MÄKIJÄRVI, M., TOIVONEN, L., & KATILA, T. (1998). Magnetocardiographic QT Interval Dispersion in Postmyocardial Infarction Patients with Sustained Ventricular Tachycardia: Validation of Automated QT Measurements. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1998.tb00013.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.