The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Complications Related to Permanent Pacemaker Therapy
Abstract
This study evaluates complications related to permanent endocardial pacing in the era of modern pacemaker therapy. There is only limited information available about the complications related to modern cardiac pacing. Most of the existing data are based on the 1970s and are no longer valid for current practice. The recent reports on pacemaker complications are focused on some specific complication or are restricted to early complications. Thus, there are no reports available providing a comprehensive view of complications related to modern cardiac pacing. Four hundred forty‐six patients, who received permanent endocardial pacemakers between January 1990 and December 1995 at Kuopio University Hospital, were reviewed retrospectively using patient records. Attention was paid to the occurrence of any complication during the implantation or follow‐up. An early complication was detected in 6.7%, and 4.9% of patients were treated invasively due to the early complication. Late complication developed in 7.2% and reoperation was required in 6.3% of the patients. Complications related to the implantation procedure occurred in 3.1%. Inadequate capture or sensing was observed in 7.4% of the patients. Pacemaker infection was detected in 1.8% and erosion in 0.9% of the patients. An AV block developed in 3.6% (1.6%/year) patients who received an AAI(R)‐pacemaker due to sick sinus syndrome. There was no mortality attributable to pacemaker therapy. A great majority (68%) of the complications occurred within the first 3 months after the implantation. Complications associated to modern permanent endocardial pacemaker therapy are not in‐frequent.Elevan percent of patients needed an invasive procedure due to an early or late complication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kruse, I., Arnman, K., Conradson, T. B., & Rydén, L. (1982) · Circulation · doi:10.1161/01.cir.65.5.846 · Cited by 294
The Natural History of Sick Sinus Syndrome: Sick Sinus Syndrome‐Histoire Naturelle
SUTTON, R., & KENNY, R. (1986) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1986.tb06678.x · Cited by 288
Aggarwal, R. K., Connelly, D. T., Ray, S. G., Ball, J., & Charles, R. G. (1995) · Heart · doi:10.1136/hrt.73.6.571 · Cited by 254
Early Complications After Dual Chamber Versus Single Chamber Pacemaker Implantation
CHAUHAN, A., GRACE, A. A., NEWELL, S. A., STONE, D. L., SHAPIRO, L. M., SCHOFIELD, P. M., & PETCH, M. C. (1994) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1994.tb03791.x · Cited by 217
The Incidence of Venous Thrombosis Following Long-Term Transvenous Pacing
Stoney, W. S., Addlestone, R. B., Alford, W. C., Burrus, G. R., Frist, R. A., & Thomas, C. S. (1976) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(10)63980-x · Cited by 210
Permanent pacemaker infections: Characterization and management
Choo, M. H., Holmes, D. R., Gersh, B. J., Maloney, J. D., Merideth, J., Pluth, J. R., & Trusty, J. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90088-6 · Cited by 177
Pacemaker-implantation complication rates: An analysis of some contributing factors
Parsonnet, V., Bernstein, A. D., & Lindsay, B. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90236-2 · Cited by 176
Randomised controlled trial of physiological and ventricular pacing.
Perrins, E. J., Morley, C. A., Chan, S. L., & Sutton, R. (1983) · Heart · doi:10.1136/hrt.50.2.112 · Cited by 160
Atrial Pacing and the Risk for AV Block: Is There a Time for Change in Attitude?
Rosenqvist, M., & Obel, I. W. P. (1989) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.1989.12.p1.97 · Cited by 145
Hill, P. E. (1987) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1987.tb04521.x · Cited by 137
Cited by
Udo, E. O., Zuithoff, N. P. A., van Hemel, N. M., de Cock, C. C., Hendriks, T., Doevendans, P. A., & Moons, K. G. M. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.014 · Cited by 597
Polyzos, K. A., Konstantelias, A. A., & Falagas, M. E. (2015) · EP Europace · doi:10.1093/europace/euv053 · Cited by 493
Cardiac Device Implantation in the United States from 1997 through 2004: A Population-based Analysis
Zhan, C., Baine, W. B., Sedrakyan, A., & Steiner, C. (2008) · Journal of General Internal Medicine · doi:10.1007/s11606-007-0392-0 · Cited by 266
Permanent Leadless Cardiac Pacemaker Therapy: A Comprehensive Review
Tjong, F. V. Y., & Reddy, V. Y. (2017) · Circulation · doi:10.1161/circulationaha.116.025037 · Cited by 228
Metadata
- Authors
- KIVINIEMI, M. S., PIRNES, M. A., ERÄNEN, H. J. K., KETTUNEN, R. V. J., & HARTIKAINEN, J. E. K.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1999-05
- Volume
- 22
- Issue
- 5
- Pages
- 711-720
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2132853139
- Cited by
- 261
- References
- 21
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complications Related to Permanent Pacemaker Therapy. https://app.cochat.ai/papers/10.1111/j.1540-8159.1999.tb00534.x
- The paper
- KIVINIEMI, M. S., PIRNES, M. A., ERÄNEN, H. J. K., KETTUNEN, R. V. J., & HARTIKAINEN, J. E. K. (1999). Complications Related to Permanent Pacemaker Therapy. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1999.tb00534.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.