Incidence and Prevention of Cardiac Tamponade Complicating Ablation for Atrial Fibrillation
The DOI matches its Crossref record.
Abstract
Cardiac tamponade complicating catheter ablation of atrial fibrillation (AF) occurs in approximately 1% of pulmonary vein isolation (PVI), and up to 6% of linear ablation procedures. We reviewed 348 consecutive AF ablation (including repeat) procedures over 1 year, which all included PVI, with additional linear lesions at the mitral isthmus in 73%, and cavotricuspid isthmus (CTI) in 76%. An irrigated‐tip ablation catheter was used, with power limited to 25–35 W for PVI and 45–60 W for linear lesions. Tamponade occurred in seven men and three women (2.9% of the population) during the creation of linear ablation lesions. Mechanical perforations occurred in two patients, and “popping” during radiofrequency (RF) energy delivery at the mitral isthmus in six, and at the CTI in two patients. Peak RF power was significantly higher in patients with than without tamponade (53 ± 4 W vs 48 ± 7 W; P = 0.02), and was greater than 48 W in all cases of “popping.” In the following year, RF power for linear ablation was limited to ≤42 W. Among 398 procedures, tamponade occurred in four patients (1.0%; P = 0.047 vs first year), three from “popping” and one from mechanical trauma. Procedural success rate remained the same despite reduction of power. Risk of tamponade was highest during linear ablation, mainly associated with high energy delivery and “popping.” Reducing the energy limited, though did not eliminate this complication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · Europace · doi:10.1093/europace/euw295 · Cited by 6,439
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw313 · Cited by 1,403
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Self-citationEHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.08.001 · Cited by 707
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux275 · Cited by 509
Self-citationAliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Bella, P. D., Hindricks, G., Jais, P., Josephson, M. E., et al. (2009) · Europace · doi:10.1093/europace/eup098 · Cited by 416
Venice Chart International Consensus Document on Atrial Fibrillation Ablation
NATALE, A., RAVIELE, A., ARENTZ, T., CALKINS, H., CHEN, S., HAÏSSAGUERRE, M., HINDRICKS, G., HO, Y., KUCK, K. H., MARCHLINSKI, F., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00816.x · Cited by 406
Self-citationPhrenic Nerve Injury After Atrial Fibrillation Catheter Ablation
Sacher, F., Monahan, K. H., Thomas, S. P., Davidson, N., Adragao, P., Sanders, P., Hocini, M., Takahashi, Y., Rotter, M., Rostock, T., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.02.050 · Cited by 344
Self-citationDAGRES, N., HINDRICKS, G., KOTTKAMP, H., SOMMER, P., GASPAR, T., BODE, K., ARYA, A., HUSSER, D., RALLIDIS, L. S., KREMASTINOS, D. T., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01493.x · Cited by 279
Bohnen, M., Stevenson, W. G., Tedrow, U. B., Michaud, G. F., John, R. M., Epstein, L. M., Albert, C. M., & Koplan, B. A. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.05.017 · Cited by 274
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.07.009 · Cited by 221
Self-citationBleeker, G. B., Mollema, S. A., Holman, E. R., Van De Veire, N., Ypenburg, C., Boersma, E., van der Wall, E. E., Schalij, M. J., & Bax, J. J. (2007) · Circulation · doi:10.1161/circulationaha.106.677005 · Cited by 190
Catheter Ablation for Cardiac Arrhythmias
Hosseini, S. M., Rozen, G., Saleh, A., Vaid, J., Biton, Y., Moazzami, K., Heist, E. K., Mansour, M. C., Kaadan, M. I., Vangel, M., et al. (2017) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2017.05.005 · Cited by 174
Catheter Ablation for Atrial Fibrillation
O’Neill, M. D., Jaïs, P., Hocini, M., Sacher, F., Klein, G. J., Clémenty, J., & Haïssaguerre, M. (2007) · Circulation · doi:10.1161/circulationaha.106.655738 · Cited by 158
Self-citation
Metadata
- Authors
- HSU, L., JAÏS, P., HOCINI, M., SANDERS, P., SCAVÉE, C., SACHER, F., TAKAHASHI, Y., ROTTER, M., PASQUIE, J., CLÉMENTY, J., & HAÏSSAGUERRE, M.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2005-01
- Volume
- 28
- Issue
- s1
- Pages
- S106-9
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2081988322
- Cited by
- 146
- References
- 0
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.