CoChat

The Value of Magnetocardiography in Patients with and Without Relevant Stenoses of the Coronary Arteries Using an Unshielded System

HAILER, BIRGIT, CHAIKOVSKY, ILJA, AUTH‐EISERNITZ, SABINE, SCHÄFER, HARALD, VAN LEEUWEN, PETER · 2005 · Pacing and Clinical Electrophysiology
Cited by 54

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: The diagnostic management of patients with chest pain remains a clinical challenge. Magnetocardiography (MCG) is a noninvasive method for the recording of cardiac electromagnetic signals at multiple sites above the chest cage. Contrary to electrocardiogram (ECG) the magnetic field is unaltered by surrounding tissues. The present study aimed to analyze the diagnostic value of an unshielded four‐channel MCG for the detection of coronary artery disease (CAD) in patients with chest pain. Methods: The study included 417 subjects: 177 patients with angiographically documented CAD (stenoses ≥50%), 123 symptomatic patients without hemodynamically relevant stenosis (nCAD) and 117 healthy subjects. Twelve‐lead ECG was obtained in all subjects. The magnetocardiography recordings were taken from 36 positions at rest. From these current density vector maps were generated during the ST‐T interval. Each map was classified using a classification system with a scale from 0 (normal) to 4 (grossly abnormal). Results: While the ECG was normal in all subjects the MCG revealed typical differences. In normals most maps were classified as category 0, 1 or 2, in nCAD and more so in CAD patients the categories 3 and 4 prevailed. Using a cut‐off value of 39.2% for the discrimination between normals and CAD patients sensitivity was 73.3%, specificity 70.1%. Conclusion: Contrary to ECG, unshielded MCG reveals significant differences between normals and symptomatic patients with and without relevant stenoses using current density reconstruction during repolarization at rest. This method might be a suitable noninvasive tool for the management of patients with chest pain.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2005.09318.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 54

Metadata

Authors
HAILER, B., CHAIKOVSKY, I., AUTH‐EISERNITZ, S., SCHÄFER, H., & VAN LEEUWEN, P.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2005-01
Volume
28
Issue
1
Pages
8-16
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2131137651
Cited by
54
References
3
FWCI
3.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Value of Magnetocardiography in Patients with and Without Relevant Stenoses of the Coronary Arteries Using an Unshielded System. https://app.cochat.ai/papers/10.1111/j.1540-8159.2005.09318.x
The paper
HAILER, B., CHAIKOVSKY, I., AUTH‐EISERNITZ, S., SCHÄFER, H., & VAN LEEUWEN, P. (2005). The Value of Magnetocardiography in Patients with and Without Relevant Stenoses of the Coronary Arteries Using an Unshielded System. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2005.09318.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.