CoChat

Radiofrequency Catheter Ablation of Common Atrial Flutter in 200 Patients

FISCHER, BRUNO, JAÏS, PIERRE, SHAH, DIPEN, CHOUAIRI, SALAH, HAÏSSAGUERRE, MICHEL, GARRIGUES, STEPHANE, FOQUET, FRANCK, GENCEL, LAURENT, CLEMENTY, JACQUES, MARCUS, FRANK I. · 1996 · Journal of Cardiovascular Electrophysiology
Cited by 103

The DOI matches its Crossref record.

Abstract

RF Ablation of Common Atrial Flutter. Introduction: The purpose of this study was to evaluate the efficacy and safety of radiofrequency (RF) catheter ablation of common atrial flutter and to determine the optimum target sites in a large series of patients. Three different approaches were used to target the ablation site. The first used a combined anatomic and electrophysiologic approach, whereas the second and the third approaches relied primarily on anatomic guidelines to target the critical area in the atrial flutter reentrant circuit located in the low right atrium. Background: Recent studies report the efficacy of RF current application in the low right atrial region to interrupt and prevent recurrences of common atrial flutter using either anatomic or electrophysiologic targets. However, larger groups of patients are required to confirm the efficacy of this technique and to specify the target sites. Methods and Results: Two hundred consecutive patients with drug‐resistant common atrial flutter were studied. In the first 50 patients, target sites were localized using both anatomic landmarks and electrophysiologic parameters. The anatomic landmarks were area 1 between the tricuspid valve and inferior vena cava orifice; area 2 between the tricuspid valve and coronary sinus ostium; and area 3 between the inferior vena cava and coronary sinus. The electrophysiologic criterion was to ablate when there was an atrial electrogram occurring during the plateau phase (preceding F wave). The first targeted area was that giving the more stable catheter position. In the following 30 patients, we assessed the effect of RF energy application in a single line to area 1 in the first 10 patients, area 2 in the next 10, and area 3 in the last 10 patients. In the last 120 patients, RF energy was applied only in area 1 using repeated applications. RF energy of 12 to 30 W, or that achieving a temperature of 70°C, was applied for 60 to 90 seconds at each site. The endpoint of the ablation procedure was interruption and noninducibility of common atrial flutter in the first 110 patients and additional isthmal block in 48 of the last 90 patients. Overall, atrial flutter was interrupted and rendered noninducihie after a single session in 191 (95%) patients and could not be interrupted in 9 (4.5%) patients. The mean number of RF applications was 12 ± 8. After a mean follow‐up of 24 ± 9 months, recurrences occurred in 31 (15.5%) patients, 26 of whom underwent a successful second or third session without further recurrences of atrial flutter. Atrial fibrillation not documented before the ablation was detected in 11 patients. On a retrospective analysis of the final successful site in the first group of 50 patients, the location was in area 1 in 39% of patients: area 2 in 36% of patients, and area 3 in 25% of patients. Atrial electrograms recorded at these sites showed a single spike pattern in 46% of patients, and double spike pattern (28%) or fractioned electrogram in 26% patients. When lines of RF lesions were placed at several sites, they produced a success rate of 70%, 40%, and 10% at areas 1, 2, and 3 respectively. In the last series of 120 patients, the procedure was

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.1996.tb00502.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 103

Metadata

Authors
FISCHER, B., JAÏS, P., SHAH, D., CHOUAIRI, S., HAÏSSAGUERRE, M., GARRIGUES, S., FOQUET, F., GENCEL, L., CLEMENTY, J., & MARCUS, F. I.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
1996-12
Volume
7
Issue
12
Pages
1225-1233
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2018029110
Cited by
103
References
0
FWCI
4.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radiofrequency Catheter Ablation of Common Atrial Flutter in 200 Patients. https://app.cochat.ai/papers/10.1111/j.1540-8167.1996.tb00502.x
The paper
FISCHER, B., JAÏS, P., SHAH, D., CHOUAIRI, S., HAÏSSAGUERRE, M., GARRIGUES, S., FOQUET, F., GENCEL, L., CLEMENTY, J., & MARCUS, F. I. (1996). Radiofrequency Catheter Ablation of Common Atrial Flutter in 200 Patients. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.1996.tb00502.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.