Cited by 39Magnetic Field Sensors TechniquesAtomic and Subatomic Physics ResearchECG Monitoring and Analysis

A portable diagnostic device for cardiac magnetic field mapping

Open access
Mooney, J W, Ghasemi-Roudsari, S, Banham, E Reade, Symonds, C, Pawlowski, N, Varcoe, B T H·2017·Biomedical Physics & Engineering Express

Abstract

In this paper we present a portable magnetocardiography device.The focus of this development was delivering a rapid assessment of chest pain in an emergency department.The aim was therefore to produce an inexpensive device that could be rapidly deployed in a noisy unshielded ward environment.We found that induction coil magnetometers with a coil design optimised for magnetic field mapping possess sufficient sensitivity ( -/ 104 fT Hz 1 2 noise floor at 10 Hz) and response ( m - 813 fT V 1 at 10 Hz) for cycle averaged magnetocardiography and are able to measure depolarisa- tion signals in an unshielded environment.We were unable to observe repolarisation signals to a reasonable fidelity.We present the design of the induction coil sensor array and signal processing routine along with data demonstrating performance in a hospital environment.

Integrity signals

Registry

Crossref · 10.1088/2057-1976/3/1/015008

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The VitalScan/Corsens features novel compact mini-induction coil magnetometers assembled in a hexagonal 19-sensors array to detect MCG from a measurement surface of about 25 cm × 25 cm.

    “it features novel compact mini-induction coil magnetometers assembled in a hexagonal 19-sensors array to detect MCG from a measurement surface of about 25 cm × 25 cm.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Mooney, J. W., Ghasemi-Roudsari, S., Banham, E. R., Symonds, C., Pawlowski, N., & Varcoe, B. T. H.
Affiliations
University of Leeds (GB)
Corresponding author
Mooney, J W
Venue
Biomedical Physics & Engineering Express
Published
2017-01-13
Volume
3
Issue
1
Pages
015008
ISSN
2057-1976 (ISSN-L)
OpenAlex
W2521075184
Cited by
39
References
7
Citations by year
2026: 5 · 2025: 1 · 2024: 8 · 2023: 7 · 2022: 4 · 2021: 2 · 2020: 3 · 2019: 2 · 2018: 6 · 2017: 1
FWCI
1.36
Type
journal article
Language
en
Open access
Locations
Biomedical Physics & Engineering Express (publishedVersion, cc-by)
Funders
  • Wellcome Trust
  • University of Leeds
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
magnetocardiography, portable diagnostic device, chest pain assessment, emergency department, sensor array design, signal processing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review