The DOI matches its Crossref record.
Embolic Events and Char Formation During Pulmonary Vein Isolation in Patients with Atrial Fibrillation: Impact of Different Anticoagulation Regimens and Importance of Intracardiac Echo Imaging
Abstract
Thromboembolic events are important complications of pulmonary vein isolation (PVI) procedures, occurring in up to 2.8% of patients. In this study, we report the incidence of char formation and embolic events with different anticoagulation protocols prospectively changed to reduce such complication. Methods: A total of 785 patients (mean age: 54 years, 83.5% male) underwent catheter‐based PVI for treatment of drug refractory, symptomatic atrial fibrillation (AF). PVI was performed utilizing different strategies including radiofrequency (RF) using temperature control energy delivery and RF using intracardiac echocardiography (ICE)‐guided power titration. Patients were divided based on the anticoagulation protocol into three groups: in group 1 (194 patients), activation coagulation time (ACT) was maintained between 250 and 300 seconds; in group 2 (180 patients), ACT was maintained between 300 and 350 seconds plus the IV infusion of eptifibatide (135 μg/kg bolus + 0.5 μg/kg/min); and in group 3 (411 patients), ACT was maintained between 350 and 400 seconds. Results: Char formation was detected in 69 patients of group 1, 5 of group 2, and 8 of group 3. An embolic event was observed in 7 patients of group 1, 3 of group 2, and 2 of group 3 (P = 0.01; group 1 vs group 3). Higher degree of anticoagulation with heparin was associated with a reduced incidence of embolic events even after removing the patients undergoing ICE‐guided ablation (P = 0.04). Conclusion: More aggressive anticoagulation with heparin reduced periprocedural embolic events. The use of platelet inhibition does not have incremental beneficial effect. None of the anticoagulation protocol abolished char formation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.08.001 · Cited by 707
Self-citationAndrade, J. G., Aguilar, M., Atzema, C., Bell, A., Cairns, J. A., Cheung, C. C., Cox, J. L., Dorian, P., Gladstone, D. J., Healey, J. S., et al. (2020) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2020.09.001 · Cited by 562
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux275 · Cited by 509
Self-citationVenice Chart International Consensus Document on Atrial Fibrillation Ablation
NATALE, A., RAVIELE, A., ARENTZ, T., CALKINS, H., CHEN, S., HAÏSSAGUERRE, M., HINDRICKS, G., HO, Y., KUCK, K. H., MARCHLINSKI, F., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00816.x · Cited by 406
Self-citationComplications of Catheter Ablation of Atrial Fibrillation: A Systematic Review
Gupta, A., Perera, T., Ganesan, A., Sullivan, T., Lau, D. H., Roberts-Thomson, K. C., Brooks, A. G., & Sanders, P. (2013) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000768 · Cited by 317
Van Belle, Y., Janse, P., Rivero-Ayerza, M. J., Thornton, A. S., Jessurun, E. R., Theuns, D., & Jordaens, L. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm227 · Cited by 297
Di Biase, L., Burkhardt, J. D., Mohanty, P., Sanchez, J., Horton, R., Gallinghouse, G. J., Lakkireddy, D., Verma, A., Khaykin, Y., Hongo, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.921320 · Cited by 294
Self-citationLeft atrial catheter ablation and ischemic stroke
Haeusler, K. G., Kirchhof, P., & Endres, M. (2012) · Stroke · doi:10.1161/strokeaha.111.627067 · Cited by 77
Metadata
- Authors
- WAZNI, O. M., ROSSILLO, A., MARROUCHE, N. F., SAAD, E. B., MARTIN, D. O., BHARGAVA, M., BASH, D., BEHEIRY, S., WEXMAN, M., POTENZA, D., PISANO, E., FANELLI, R., BONSO, A., THEMISTOCLAKIS, S., ERCIYES, D., SALIBA, W. I., SCHWEIKERT, R. A., BRACHMANN, J., RAVIELE, A., & NATALE, A.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2005-04-26
- Volume
- 16
- Issue
- 6
- Pages
- 576-581
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2087820923
- Cited by
- 176
- References
- 0
- FWCI
- 11.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.