Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 297

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome

Open access
Van Belle, Y., Janse, P., Rivero-Ayerza, M. J., Thornton, A. S., Jessurun, E. R., Theuns, D., Jordaens, L. · 2007 · European Heart Journal

Abstract

AIMS: To assess safety, feasibility and short term outcome of pulmonary vein (PV) isolation in paroxysmal atrial fibrillation (AF) with a cryoballoon. METHODS: We consecutively treated 57 patients with a double lumen 23 or 28 mm cryoballoon. The acute results, complications and follow-up over the first three months were analysed, using a comprehensive and intensive follow-up period. RESULTS: During 57 procedures, 185 of 220 targeted PV's were successfully isolated using the cryoballoon (84%) (balloon group, 33 patients). In 33 veins (15%) an additional segmental isolation (hybrid group, 24 patients) was necessary with a standard cryocatheter to achieve isolation. The average procedure times were respectively 211 +/- 108 and 261 +/- 83 minutes (NS), the average fluoroscopy times 52 +/- 36 and 66 +/- 33 minutes (NS). The number of balloon applications did not differ between both groups: respectively a median 9 (4-18) and 10 (5-17) (NS). We observed four phrenic nerve paralysis after ablation of the right superior PV: two resolved immediately after cessation of the cryoenergy, one recovered after 3 months, one persisted up to 6 months. A daily transtelephonic rhythm recording showed a significant drop in mean AF burden from 24% to 10%, 8% and 5% during the three consecutive months of follow-up (p < 0.01 versus baseline). No differences were observed between the treatment groups. 34 patients (60%) were completely free from AF after a single procedure. CONCLUSIONS: Balloon cryoablation of the pulmonary veins with additional segmental isolation if necessary, is a good approach for patients presenting with paroxysmal AF, showing a significant reduction in AF burden after a single procedure. The major complication seems to be phrenic nerve paralysis after ablation of the right superior PV, but this is potentially reversible over several months.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehm227

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 40 references

Cited by

See all 297

Metadata

Authors
Van Belle, Y., Janse, P., Rivero-Ayerza, M. J., Thornton, A. S., Jessurun, E. R., Theuns, D., & Jordaens, L.
Venue
European Heart Journal
Published
2007-08-02
Volume
28
Issue
18
Pages
2231-2237
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2112050838
Cited by
297
References
40
FWCI
14.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. https://app.cochat.ai/papers/10.1093/eurheartj/ehm227
The paper
Van Belle, Y., Janse, P., Rivero-Ayerza, M. J., Thornton, A. S., Jessurun, E. R., Theuns, D., & Jordaens, L. (2007). Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. European Heart Journal. https://doi.org/10.1093/eurheartj/ehm227

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.