The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Validation of Three‐Dimensional Cardiac Image Integration: Use of Integrated CT Image into Electroanatomic Mapping System to Perform Catheter Ablation of Atrial Fibrillation
Abstract
Introduction: Accurate visualization of the complex left atrial (LA) anatomy and the location of an ablation catheter within the chamber is important in the success and safety of ablation for atrial fibrillation (AF). We describe the integration of CT into an electroanatomic mapping (EAM) system and its validation in patients undergoing catheter ablation for AF. Methods and Results: Thirty patients (59.2 ± 8 years, 25 M) with paroxysmal (12) and persistent (18) AF underwent ablation using CT image integration into an electroanatomic mapping system. CT registration using the pulmonary veins as markers (landmark) was achieved with an error of 6.4 ± 2.8 mm with repeat registration required in two patients. Registration of the CT by best fit to a electroanatomic geometry (surface) was achieved with an error of 2.3 ± 0.4 mm. There was no significant difference in the regional LA registration error at superior (1.7 ± 0.7 mm), inferior (2.2 ± 1.4 mm), septal (1.7 ± 0.8 mm), and lateral (1.7 ± 0.7 mm, P = 0.13) sites. Cardiac rhythm at the time of CT did not have a significant effect on total or regional surface registration accuracy (mean total 2.5 ± 0.3 in AF patients vs 2.3 ± 0.5 in SR patients, P = 0.22). The integrated CT was used to guide the encirclement of the pulmonary veins (PV) in pairs with electrical isolation achieved by maintaining ablation along the ablation line in 58 of 60 PV pairs. Postprocedural PV angiography did not demonstrate significant stenosis. Conclusion: CT image integration into an EAM system was successfully performed in patients undergoing catheter ablation for AF. With a greater appreciation of the complex and variable nature of the PV and LA anatomy this new technology may improve the efficacy and safety of the procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Cited by
Venice Chart International Consensus Document on Atrial Fibrillation Ablation
NATALE, A., RAVIELE, A., ARENTZ, T., CALKINS, H., CHEN, S., HAÏSSAGUERRE, M., HINDRICKS, G., HO, Y., KUCK, K. H., MARCHLINSKI, F., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00816.x · Cited by 406
Self-citationDONG, J., DALAL, D., SCHERR, D., CHEEMA, A., NAZARIAN, S., BILCHICK, K., ALMASRY, I., CHENG, A., HENRIKSON, C. A., SPRAGG, D., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00956.x · Cited by 316
KISTLER, P. M., HO, S. Y., RAJAPPAN, K., MORPER, M., HARRIS, S., ABRAMS, D., SPORTON, S. C., & SCHILLING, R. J. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00981.x · Cited by 290
Self-citationKISTLER, P. M., RAJAPPAN, K., JAHNGIR, M., EARLEY, M. J., HARRIS, S., ABRAMS, D., GUPTA, D., LIEW, R., ELLIS, S., SPORTON, S. C., et al. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00594.x · Cited by 272
Self-citation
Metadata
- Authors
- KISTLER, P. M., EARLEY, M. J., HARRIS, S., ABRAMS, D., ELLIS, S., SPORTON, S. C., & SCHILLING, R. J.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2006-02-17
- Volume
- 17
- Issue
- 4
- Pages
- 341-348
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2028806735
- Cited by
- 182
- References
- 1
- FWCI
- 18.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of Three‐Dimensional Cardiac Image Integration: Use of Integrated CT Image into Electroanatomic Mapping System to Perform Catheter Ablation of Atrial Fibrillation. https://app.cochat.ai/papers/10.1111/j.1540-8167.2006.00371.x
- The paper
- KISTLER, P. M., EARLEY, M. J., HARRIS, S., ABRAMS, D., ELLIS, S., SPORTON, S. C., & SCHILLING, R. J. (2006). Validation of Three‐Dimensional Cardiac Image Integration: Use of Integrated CT Image into Electroanatomic Mapping System to Perform Catheter Ablation of Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2006.00371.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.