Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Validation of Three‐Dimensional Cardiac Image Integration: Use of Integrated CT Image into Electroanatomic Mapping System to Perform Catheter Ablation of Atrial Fibrillation

KISTLER, PETER M., EARLEY, MARK J., HARRIS, STUART, ABRAMS, DOMINIC, ELLIS, STEPHEN, SPORTON, SIMON C., SCHILLING, RICHARD J.·2006·Journal of Cardiovascular Electrophysiology

Abstract

Introduction: Accurate visualization of the complex left atrial (LA) anatomy and the location of an ablation catheter within the chamber is important in the success and safety of ablation for atrial fibrillation (AF). We describe the integration of CT into an electroanatomic mapping (EAM) system and its validation in patients undergoing catheter ablation for AF. Methods and Results: Thirty patients (59.2 ± 8 years, 25 M) with paroxysmal (12) and persistent (18) AF underwent ablation using CT image integration into an electroanatomic mapping system. CT registration using the pulmonary veins as markers (landmark) was achieved with an error of 6.4 ± 2.8 mm with repeat registration required in two patients. Registration of the CT by best fit to a electroanatomic geometry (surface) was achieved with an error of 2.3 ± 0.4 mm. There was no significant difference in the regional LA registration error at superior (1.7 ± 0.7 mm), inferior (2.2 ± 1.4 mm), septal (1.7 ± 0.8 mm), and lateral (1.7 ± 0.7 mm, P = 0.13) sites. Cardiac rhythm at the time of CT did not have a significant effect on total or regional surface registration accuracy (mean total 2.5 ± 0.3 in AF patients vs 2.3 ± 0.5 in SR patients, P = 0.22). The integrated CT was used to guide the encirclement of the pulmonary veins (PV) in pairs with electrical isolation achieved by maintaining ablation along the ablation line in 58 of 60 PV pairs. Postprocedural PV angiography did not demonstrate significant stenosis. Conclusion: CT image integration into an EAM system was successfully performed in patients undergoing catheter ablation for AF. With a greater appreciation of the complex and variable nature of the PV and LA anatomy this new technology may improve the efficacy and safety of the procedure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2006.00371.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 182

Metadata

Authors
KISTLER, P. M., EARLEY, M. J., HARRIS, S., ABRAMS, D., ELLIS, S., SPORTON, S. C., & SCHILLING, R. J.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2006-02-17
Volume
17
Issue
4
Pages
341-348
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2028806735
Cited by
182
References
1
FWCI
18.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of Three‐Dimensional Cardiac Image Integration: Use of Integrated CT Image into Electroanatomic Mapping System to Perform Catheter Ablation of Atrial Fibrillation. https://app.cochat.ai/papers/10.1111/j.1540-8167.2006.00371.x
The paper
KISTLER, P. M., EARLEY, M. J., HARRIS, S., ABRAMS, D., ELLIS, S., SPORTON, S. C., & SCHILLING, R. J. (2006). Validation of Three‐Dimensional Cardiac Image Integration: Use of Integrated CT Image into Electroanatomic Mapping System to Perform Catheter Ablation of Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2006.00371.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.